An Ultrasonically Powered Implantable Micro-Oxygen Generator (IMOG)
The DOI matches its Crossref record.
Abstract
In this paper, we present an ultrasonically powered implantable micro-oxygen generator (IMOG) that is capable of in situ tumor oxygenation through water electrolysis. Such active mode of oxygen generation is not affected by increased interstitial pressure or abnormal blood vessels that typically limit the systemic delivery of oxygen to hypoxic regions of solid tumors. Wireless ultrasonic powering (2.15 MHz) was employed to increase the penetration depth and eliminate the directional sensitivity associated with magnetic methods. In addition, ultrasonic powering allowed for further reduction in the total size of the implant by eliminating the need for a large area inductor. IMOG has an overall dimension of 1.2 mm × 1.3 mm × 8 mm, small enough to be implanted using a hypodermic needle or a trocar. In vitro and ex vivo experiments showed that IMOG is capable of generating more than 150 μA which, in turn, can create 0.525 μL/min of oxygen through electrolytic disassociation. In vivo experiments in a well-known hypoxic pancreatic tumor models (1 cm (3) in size) also verified adequate in situ tumor oxygenation in less than 10 min.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
Yao, C., Wang, W., Wang, P., Zhao, M., Li, X., & Zhang, F. (2018) · Advanced Materials · doi:10.1002/adma.201704833 · Cited by 447
Huang, C.-C., Chia, W.-T., Chung, M.-F., Lin, K.-J., Hsiao, C.-W., Jin, C., Lim, W.-H., Chen, C.-C., & Sung, H.-W. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.6b01784 · Cited by 372
Wireless power transfer techniques for implantable medical devices: a review
Khan, S. R., Pavuluri, S. K., Cummins, G., & Desmulliez, M. P. Y. (2020) · Sensors · doi:10.3390/s20123487 · Cited by 355
Roy, S., Azad, A. N. M. W., Baidya, S., Alam, M. K., & Khan, F. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2022.3164890 · Cited by 255
Metadata
- Authors
- Maleki, T., Cao, N., Song, S. H., Kao, C., Ko, S.-C., & Ziaie, B.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2011-11
- Volume
- 58
- Issue
- 11
- Pages
- 3104-3111
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2138158977
- Cited by
- 156
- References
- 0
- FWCI
- 3.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Ultrasonically Powered Implantable Micro-Oxygen Generator (IMOG). https://app.cochat.ai/papers/10.1109/tbme.2011.2163634
- The paper
- Maleki, T., Cao, N., Song, S. H., Kao, C., Ko, S.-C., & Ziaie, B. (2011). An Ultrasonically Powered Implantable Micro-Oxygen Generator (IMOG). IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2011.2163634
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.