The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
A Miniature Vibrotactile Sensory Substitution Device for Multifingered Hand Prosthetics
Abstract
A multisite, vibrotactile sensory substitution system, that could be used in conjunction with artificial touch sensors in multifingered prostheses, to deliver sensory feedback to upper limb amputees is presented. The system is based on a low cost/power/size smart architecture of off-the-shelf miniaturized vibration motors; the main novelty is that it is able to generate stimuli where both vibration amplitude and frequency as well as beat interference can be modulated. This paper is aimed at evaluating this system by investigating the capability of healthy volunteers to perceive-on their forearms-vibrations with different amplitudes and/or frequencies. In addition, the ability of subjects in spatially discriminating stimulations on three forearm sites and recognizing six different combinations of stimulations was also addressed. Results demonstrate that subjects were able to discriminate different force amplitudes exerted by the device (accuracies greater than 75%); when both amplitude and frequency were simultaneously varied, the pure discrimination of amplitude/frequency variation was affected by the variation of the other. Subjects were also able to discriminate with an accuracy of 93% three different sites and with an accuracy of 78% six different stimulation patterns.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Consumer design priorities for upper limb prosthetics
Biddiss, E., Beaton, D., & Chau, T. (2007) · Disability and Rehabilitation: Assistive Technology · doi:10.1080/17483100701714733 · Cited by 519
Double nerve intraneural interface implant on a human amputee for robotic hand control
Rossini, P. M., Micera, S., Benvenuto, A., Carpaneto, J., Cavallo, G., Citi, L., Cipriani, C., Denaro, L., Denaro, V., Di Pino, G., et al. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.001 · Cited by 396
Self-citationRobotic touch shifts perception of embodiment to a prosthesis in targeted reinnervation amputees
Marasco, P. D., Kim, K., Colgate, J. E., Peshkin, M. A., & Kuiken, T. A. (2011) · Brain · doi:10.1093/brain/awq361 · Cited by 335
Design and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands
Pylatiuk, C., Kargov, A., & Schulz, S. (2006) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-200604000-00007 · Cited by 156
Cited by
Sensory feedback in upper limb prosthetics
Antfolk, C., D’Alonzo, M., Rosén, B., Lundborg, G., Sebelius, F., & Cipriani, C. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.12.68 · Cited by 466
Self-citationLosey, D. P., McDonald, C. G., Battaglia, E., & O'Malley, M. K. (2018) · Applied Mechanics Reviews · doi:10.1115/1.4039145 · Cited by 392
A Review of Non-Invasive Sensory Feedback Methods for Transradial Prosthetic Hands
Stephens-Fripp, B., Alici, G., & Mutlu, R. (2018) · IEEE Access · doi:10.1109/access.2018.2791583 · Cited by 210
Forearm amputees' views of prosthesis use and sensory feedback
Wijk, U., & Carlsson, I. (2015) · Journal of Hand Therapy · doi:10.1016/j.jht.2015.01.013 · Cited by 114
Neural interfaces for somatosensory feedback: bringing life to a prosthesis
Tyler, D. J. (2015) · Current Opinion in Neurology · doi:10.1097/wco.0000000000000266 · Cited by 105
Metadata
- Authors
- Cipriani, C., D'Alonzo, M., & Carrozza, M. C.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2012-02
- Volume
- 59
- Issue
- 2
- Pages
- 400-408
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2027458696
- Cited by
- 164
- References
- 5
- FWCI
- 5.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.