CoChat

Surface Laplacian of Central Scalp Electrical Signals is Insensitive to Muscle Contamination

Fitzgibbon, S. P., Lewis, T. W., Powers, D. M. W., Whitham, E. W., Willoughby, J. O., Pope, K. J. · 2013 · IEEE Transactions on Biomedical Engineering

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Abstract

The objective of this paper was to investigate the effects of surface Laplacian processing on gross and persistent electromyographic (EMG) contamination of electroencephalographic (EEG) signals in electrical scalp recordings. We made scalp recordings during passive and active tasks, on awake subjects in the absence and in the presence of complete neuromuscular blockade. Three scalp surface Laplacian estimators were compared to left ear and common average reference (CAR). Contamination was quantified by comparing power after paralysis (brain signal, B) with power before paralysis (brain plus muscle signal, B+M). Brain:Muscle (B:M) ratios for the methods were calculated using B and differences in power after paralysis to represent muscle (M). There were very small power differences after paralysis up to 600 Hz using surface Laplacian transforms (B:M > 6 above 30 Hz in central scalp leads). Scalp surface Laplacian transforms reduce muscle power in central and pericentral leads to less than one sixth of the brain signal, two to three times better signal detection than CAR. Scalp surface Laplacian transformations provide robust estimates for detecting high-frequency (gamma) activity, for assessing electrophysiological correlates of disease, and also for providing a measure of brain electrical activity for use as a standard in the development of brain/muscle signal separation methods.

Overview

Integrity signals

Registry

Crossref · 10.1109/tbme.2012.2195662

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 21 references

Cited by

See all 67

Metadata

Authors
Fitzgibbon, S. P., Lewis, T. W., Powers, D. M. W., Whitham, E. W., Willoughby, J. O., & Pope, K. J.
Affiliations
Flinders University (AU)
Venue
IEEE Transactions on Biomedical Engineering
Published
2013-01
Volume
60
Issue
1
Pages
4-9
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W1964964988
Cited by
67
References
21
Citations by year
2026: 1 · 2025: 3 · 2024: 2 · 2023: 2 · 2022: 3 · 2021: 2 · 2020: 7 · 2019: 3 · 2018: 6 · 2017: 10 · 2016: 4 · 2015: 5 · 2014: 6 · 2013: 12
FWCI
3.93
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • Flinders Academic Commons (Flinders University) (submittedVersion)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
Keywords
EEG signal processing, muscle artifacts, neuromuscular blockade, common average reference, gamma oscillations
MeSH terms
Adult, Aged, Electroencephalography, Electromyography, Evoked Potentials, Visual, Female, Humans, Male, Middle Aged, Scalp, Signal Processing, Computer-Assisted, Task Performance and Analysis, Muscle, Skeletal

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Surface Laplacian of Central Scalp Electrical Signals is Insensitive to Muscle Contamination. https://app.cochat.ai/papers/10.1109/tbme.2012.2195662
The paper
Fitzgibbon, S. P., Lewis, T. W., Powers, D. M. W., Whitham, E. W., Willoughby, J. O., & Pope, K. J. (2013). Surface Laplacian of Central Scalp Electrical Signals is Insensitive to Muscle Contamination. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2012.2195662

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.