Surface Laplacian of Central Scalp Electrical Signals is Insensitive to Muscle Contamination
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
The objective of this paper was to investigate the effects of surface Laplacian processing on gross and persistent electromyographic (EMG) contamination of electroencephalographic (EEG) signals in electrical scalp recordings. We made scalp recordings during passive and active tasks, on awake subjects in the absence and in the presence of complete neuromuscular blockade. Three scalp surface Laplacian estimators were compared to left ear and common average reference (CAR). Contamination was quantified by comparing power after paralysis (brain signal, B) with power before paralysis (brain plus muscle signal, B+M). Brain:Muscle (B:M) ratios for the methods were calculated using B and differences in power after paralysis to represent muscle (M). There were very small power differences after paralysis up to 600 Hz using surface Laplacian transforms (B:M > 6 above 30 Hz in central scalp leads). Scalp surface Laplacian transforms reduce muscle power in central and pericentral leads to less than one sixth of the brain signal, two to three times better signal detection than CAR. Scalp surface Laplacian transformations provide robust estimates for detecting high-frequency (gamma) activity, for assessing electrophysiological correlates of disease, and also for providing a measure of brain electrical activity for use as a standard in the development of brain/muscle signal separation methods.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“By referencing the EEG tracing at a given electrode to that of its nearest neighbors, the Laplacian reference mitigates the effect of diffuse activity sensed by multiple electrodes (including volume-conducted artifact but also widespread neural activity) and improves sensitivity to local activity.”
From EEG power at 3 months in infants at high familial risk for autism (2017) · cites this paper as [27]
Citations
Cites
Oostenveld, R., Fries, P., Maris, E., & Schoffelen, J.-M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/156869 · Cited by 10,323 · cited 1×
“Code for all estimators was obtained from the FieldTrip toolbox [16].”
MethodBuzsáki, G. (2006) · doi:10.1093/acprof:oso/9780195301069.001.0001 · Cited by 4,873 · cited 1×
“paralyzed) and paralyzed awake volunteers undertaking various mental and motor tasks, we have demonstrated that spline surface Laplacian transform of signals from central scalp positions has very high B:M ratios over all frequencies at which cerebral rhythms have been considered to be likely [18].”
BackgroundMeasuring phase synchrony in brain signals
Lachaux, J.-P., Rodriguez, E., Martinerie, J., & Varela, F. J. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)8:4<194::aid-hbm4>3.0.co;2-c · Cited by 3,798 · cited 1×
“While there is evidence to suggest that surface Laplacian will benefit estimates of synchrony [19], [20], caution should be exercised to ensure that analyses, particularly phase analyses (e.”
BackgroundElectroencephalography—Basic principles, clinical applications and related fields
(1982) · Journal of the Autonomic Nervous System · doi:10.1016/0165-1838(82)90067-4 · Cited by 3,427
Spherical splines for scalp potential and current density mapping
Perrin, F., Pernier, J., Bertrand, O., & Echallier, J. F. (1989) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(89)90180-6 · Cited by 2,706 · cited 1×
“Three forms of surface Laplacian transforms were tested: a spline interpolation [14], Hjorth [15], and finite element [13].”
MethodNunez, P. L., & Srinivasan, R. (2006) · doi:10.1093/acprof:oso/9780195050387.001.0001 · Cited by 2,531
Delorme, A., Sejnowski, T., & Makeig, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.004 · Cited by 1,759 · cited 2×
“techniques, none of which have yet been demonstrably reliable [9]–[11].”
BackgroundAn on-line transformation of EEG scalp potentials into orthogonal source derivations
Hjorth, B. (1975) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(75)90056-5 · Cited by 1,012 · cited 3×
“Average topographies (n = 6) of relative power for left ear, CAR, and nearest neighbor (Hjorth), spline, finite-element surface Laplacian transforms.”
MethodTemporal coding in the visual cortex: new vistas on integration in the nervous system
Engel, A. K., König, P., Kreiter, A. K., Schillen, T. B., & Singer, W. (1992) · Trends in Neurosciences · doi:10.1016/0166-2236(92)90039-b · Cited by 755
EMG contamination of EEG: spectral and topographical characteristics
Goncharova, I. I., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00093-2 · Cited by 696 · cited 4×
“It is well known that electrical activity from muscles [electromyogram (EMG)] of the cranium and neck contaminates scalp recordings, and the spectrum of frequencies in the EMG overlaps the spectrum of the EEG particularly above 20 Hz [4], [5], and we have quantified the extent of the contamination [6]–[8].”
BackgroundMethodInfluential
Cited by
High-Frequency Brain Activity and Muscle Artifacts in MEG/EEG: A Review and Recommendations
Muthukumaraswamy, S. D. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00138 · Cited by 697
“…approaches that have been used for attenuating muscle artifacts are based on spatial filtering, including the derivation of Laplacian montages (Fitzgibbon et al., 2013) for EEG, ICA (Shackman et al., 2009; McMenamin et al., 2011; Scheeringa et al., 2011), and beamformer source localization…”
MethodInfluentialInterpreting EEG alpha activity
Bazanova, O. M., & Vernon, D. (2014) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2013.05.007 · Cited by 574
“…ransformations have been shown to provide robust estimates for etecting high frequency EMG amplitude and also for providing a easure of electrical brain activity and as such could be used as standard in the development of brain/muscle signal separation ethods (see e.g., Fitzgibbon et al., 2012).”
Rashid, M., Sulaiman, N., P. P. Abdul Majeed, A., Musa, R. M., Ab. Nasir, A. F., Bari, B. S., & Khatun, S. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00025 · Cited by 506
“…removal techniques are required such as adaptive filtering, Wiener filtering, Bayes filtering (Sweeney et al., 2012), surface Laplacian transforms (Fitzgibbon et al., 2013), regression (Gratton et al., 1983), Common Average Referencing (CAR) (Zaizu Ilyas et al., 2015), EOG correction (Croft and…”
Methodvan Diessen, E., Numan, T., van Dellen, E., van der Kooi, A. W., Boersma, M., Hofman, D., van Lutterveld, R., van Dijk, B. W., van Straaten, E. C. W., Hillebrand, A., et al. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.11.018 · Cited by 417
An electrophysiological marker of arousal level in humans
Lendner, J. D., Helfrich, R. F., Mander, B. A., Romundstad, L., Lin, J. J., Walker, M. P., Larsson, P. G., & Knight, R. T. (2020) · eLife · doi:10.7554/elife.55092 · Cited by 410
“Since frequencies of cranial muscle activity overlap with the frequency range used for spectral slope estimation, we controlled for possible muscle artifacts by repeating the analysis after local referencing (Laplacian; Fitzgibbon et al., 2013).”
Method
Metadata
- Authors
- Fitzgibbon, S. P., Lewis, T. W., Powers, D. M. W., Whitham, E. W., Willoughby, J. O., & Pope, K. J.
- Affiliations
- Flinders University (AU)
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2013-01
- Volume
- 60
- Issue
- 1
- Pages
- 4-9
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W1964964988
- Cited by
- 67
- References
- 21
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 2 · 2023: 2 · 2022: 3 · 2021: 2 · 2020: 7 · 2019: 3 · 2018: 6 · 2017: 10 · 2016: 4 · 2015: 5 · 2014: 6 · 2013: 12
- FWCI
- 3.93
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Flinders Academic Commons (Flinders University) (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- EEG signal processing, muscle artifacts, neuromuscular blockade, common average reference, gamma oscillations
- MeSH terms
- Adult, Aged, Electroencephalography, Electromyography, Evoked Potentials, Visual, Female, Humans, Male, Middle Aged, Scalp, Signal Processing, Computer-Assisted, Task Performance and Analysis, Muscle, Skeletal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Surface Laplacian of Central Scalp Electrical Signals is Insensitive to Muscle Contamination. https://app.cochat.ai/papers/10.1109/tbme.2012.2195662
- The paper
- Fitzgibbon, S. P., Lewis, T. W., Powers, D. M. W., Whitham, E. W., Willoughby, J. O., & Pope, K. J. (2013). Surface Laplacian of Central Scalp Electrical Signals is Insensitive to Muscle Contamination. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2012.2195662
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.