Surface Laplacian of Central Scalp Electrical Signals is Insensitive to Muscle Contamination
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
The objective of this paper was to investigate the effects of surface Laplacian processing on gross and persistent electromyographic (EMG) contamination of electroencephalographic (EEG) signals in electrical scalp recordings. We made scalp recordings during passive and active tasks, on awake subjects in the absence and in the presence of complete neuromuscular blockade. Three scalp surface Laplacian estimators were compared to left ear and common average reference (CAR). Contamination was quantified by comparing power after paralysis (brain signal, B) with power before paralysis (brain plus muscle signal, B+M). Brain:Muscle (B:M) ratios for the methods were calculated using B and differences in power after paralysis to represent muscle (M). There were very small power differences after paralysis up to 600 Hz using surface Laplacian transforms (B:M > 6 above 30 Hz in central scalp leads). Scalp surface Laplacian transforms reduce muscle power in central and pericentral leads to less than one sixth of the brain signal, two to three times better signal detection than CAR. Scalp surface Laplacian transformations provide robust estimates for detecting high-frequency (gamma) activity, for assessing electrophysiological correlates of disease, and also for providing a measure of brain electrical activity for use as a standard in the development of brain/muscle signal separation methods.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“By referencing the EEG tracing at a given electrode to that of its nearest neighbors, the Laplacian reference mitigates the effect of diffuse activity sensed by multiple electrodes (including volume-conducted artifact but also widespread neural activity) and improves sensitivity to local activity.”
From EEG power at 3 months in infants at high familial risk for autism (2017) · cites this paper as [27]
Citations
Cites
Oostenveld, R., Fries, P., Maris, E., & Schoffelen, J.-M. (2011) · Computational Intelligence and Neuroscience · doi:10.1155/2011/156869 · Cited by 10,323 · cited 1×
“Code for all estimators was obtained from the FieldTrip toolbox [16].”
MethodBuzsáki, G. (2006) · doi:10.1093/acprof:oso/9780195301069.001.0001 · Cited by 4,873 · cited 1×
“paralyzed) and paralyzed awake volunteers undertaking various mental and motor tasks, we have demonstrated that spline surface Laplacian transform of signals from central scalp positions has very high B:M ratios over all frequencies at which cerebral rhythms have been considered to be likely [18].”
BackgroundMeasuring phase synchrony in brain signals
Lachaux, J.-P., Rodriguez, E., Martinerie, J., & Varela, F. J. (1999) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1999)8:4<194::aid-hbm4>3.0.co;2-c · Cited by 3,798 · cited 1×
“While there is evidence to suggest that surface Laplacian will benefit estimates of synchrony [19], [20], caution should be exercised to ensure that analyses, particularly phase analyses (e.”
BackgroundElectroencephalography—Basic principles, clinical applications and related fields
(1982) · Journal of the Autonomic Nervous System · doi:10.1016/0165-1838(82)90067-4 · Cited by 3,427
Spherical splines for scalp potential and current density mapping
Perrin, F., Pernier, J., Bertrand, O., & Echallier, J. F. (1989) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(89)90180-6 · Cited by 2,706 · cited 1×
“Three forms of surface Laplacian transforms were tested: a spline interpolation [14], Hjorth [15], and finite element [13].”
MethodNunez, P. L., & Srinivasan, R. (2006) · doi:10.1093/acprof:oso/9780195050387.001.0001 · Cited by 2,531
Delorme, A., Sejnowski, T., & Makeig, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.004 · Cited by 1,759 · cited 2×
“techniques, none of which have yet been demonstrably reliable [9]–[11].”
BackgroundAn on-line transformation of EEG scalp potentials into orthogonal source derivations
Hjorth, B. (1975) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(75)90056-5 · Cited by 1,012 · cited 3×
“Average topographies (n = 6) of relative power for left ear, CAR, and nearest neighbor (Hjorth), spline, finite-element surface Laplacian transforms.”
MethodTemporal coding in the visual cortex: new vistas on integration in the nervous system
Engel, A. K., König, P., Kreiter, A. K., Schillen, T. B., & Singer, W. (1992) · Trends in Neurosciences · doi:10.1016/0166-2236(92)90039-b · Cited by 755
EMG contamination of EEG: spectral and topographical characteristics
Goncharova, I. I., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2003) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00093-2 · Cited by 696 · cited 4×
“It is well known that electrical activity from muscles [electromyogram (EMG)] of the cranium and neck contaminates scalp recordings, and the spectrum of frequencies in the EMG overlaps the spectrum of the EEG particularly above 20 Hz [4], [5], and we have quantified the extent of the contamination [6]–[8].”
BackgroundMethodInfluential
Cited by
High-Frequency Brain Activity and Muscle Artifacts in MEG/EEG: A Review and Recommendations
Muthukumaraswamy, S. D. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00138 · Cited by 697
“…approaches that have been used for attenuating muscle artifacts are based on spatial filtering, including the derivation of Laplacian montages (Fitzgibbon et al., 2013) for EEG, ICA (Shackman et al., 2009; McMenamin et al., 2011; Scheeringa et al., 2011), and beamformer source localization…”
MethodInfluentialInterpreting EEG alpha activity
Bazanova, O. M., & Vernon, D. (2014) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2013.05.007 · Cited by 574
“…ransformations have been shown to provide robust estimates for etecting high frequency EMG amplitude and also for providing a easure of electrical brain activity and as such could be used as standard in the development of brain/muscle signal separation ethods (see e.g., Fitzgibbon et al., 2012).”
Rashid, M., Sulaiman, N., P. P. Abdul Majeed, A., Musa, R. M., Ab. Nasir, A. F., Bari, B. S., & Khatun, S. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00025 · Cited by 506
“…removal techniques are required such as adaptive filtering, Wiener filtering, Bayes filtering (Sweeney et al., 2012), surface Laplacian transforms (Fitzgibbon et al., 2013), regression (Gratton et al., 1983), Common Average Referencing (CAR) (Zaizu Ilyas et al., 2015), EOG correction (Croft and…”
Methodvan Diessen, E., Numan, T., van Dellen, E., van der Kooi, A. W., Boersma, M., Hofman, D., van Lutterveld, R., van Dijk, B. W., van Straaten, E. C. W., Hillebrand, A., et al. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.11.018 · Cited by 417
An electrophysiological marker of arousal level in humans
Lendner, J. D., Helfrich, R. F., Mander, B. A., Romundstad, L., Lin, J. J., Walker, M. P., Larsson, P. G., & Knight, R. T. (2020) · eLife · doi:10.7554/elife.55092 · Cited by 410
“Since frequencies of cranial muscle activity overlap with the frequency range used for spectral slope estimation, we controlled for possible muscle artifacts by repeating the analysis after local referencing (Laplacian; Fitzgibbon et al., 2013).”
MethodEEG source localization: Sensor density and head surface coverage
Song, J., Davey, C., Poulsen, C., Luu, P., Turovets, S., Anderson, E., Li, K., & Tucker, D. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.08.015 · Cited by 356
Measuring Mental Workload with EEG+fNIRS
Aghajani, H., Garbey, M., & Omurtag, A. (2017) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2017.00359 · Cited by 236
“We located the fNIRS optodes on the subject’s forehead to fully cover the PFC, which plays a significant role in WM (Fitzgibbon et al., 2013).”
BackgroundMethodMuthukumaraswamy, S. D., & Singh, K. D. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.12.038 · Cited by 160
“, 2009) or surface laplacian estimation (Fitzgibbon et al., 2013).”
Noda, Y., Zomorrodi, R., Saeki, T., Rajji, T. K., Blumberger, D. M., Daskalakis, Z. J., & Nakamura, M. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2016.12.023 · Cited by 155
Freezing of gait in Parkinson’s disease reflects a sudden derangement of locomotor network dynamics
Pozzi, N. G., Canessa, A., Palmisano, C., Brumberg, J., Steigerwald, F., Reich, M. M., Minafra, B., Pacchetti, C., Pezzoli, G., Volkmann, J., et al. (2019) · Brain · doi:10.1093/brain/awz141 · Cited by 149
Prefrontal gamma oscillations reflect ongoing pain intensity in chronic back pain patients
May, E. S., Nickel, M. M., Dinh, S. T., Tiemann, L., Heitmann, H., Voth, I., Tölle, T. R., Groß, J., & Ploner, M. (2018) · Human Brain Mapping · doi:10.1002/hbm.24373 · Cited by 173
“…referencing according to interelectrode distances, the surface Laplacian aims at attenuating low spatial frequency components in the data and improving topographical localization and has been suggested as a tool to reduce EMG contamination (Fitzgibbon et al., 2013; Fitzgibbon et al., 2015).”
BackgroundRemoval of Muscle Artifacts From the EEG: A Review and Recommendations
Chen, X., Xu, X., Liu, A., Lee, S., Chen, X. '., Zhang, X., McKeown, M. J., & Wang, Z. J. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2906572 · Cited by 147
“Although SLT has been demonstrated its effective performance on muscle artifact elimination in central scalp signals, the use of the method to reduce EMG artifacts from peripheral scalp locations remains problematic [19], [57].”
BackgroundMethodInfluentialBEAPP: The Batch Electroencephalography Automated Processing Platform
Levin, A. R., Méndez Leal, A. S., Gabard-Durnam, L. J., & O’Leary, H. M. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00513 · Cited by 124
The Surface Laplacian Technique in EEG: Theory and MethodsPreprint
Carvalhaes, C. G., & Barrosb, J. A. D. (2016) · Cited by 140
EEG power at 3 months in infants at high familial risk for autism
Levin, A. R., Varcin, K. J., O’Leary, H. M., Tager-Flusberg, H., & Nelson, C. A. (2017) · Journal of Neurodevelopmental Disorders · doi:10.1186/s11689-017-9214-9 · Cited by 107
“We took numerous steps to limit the impact of such artifact on our data, including the use of the Laplacian reference, [27] conservative artifact removal in which epochs with even one channel with high-amplitude artifact were removed from further analysis, verification that the slope of the power spectra was always <−…”
BackgroundMethodvan Lutterveld, R., Houlihan, S. D., Pal, P., Sacchet, M. D., McFarlane-Blake, C., Patel, P. R., Sullivan, J. S., Ossadtchi, A., Druker, S., Bauer, C., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.02.047 · Cited by 88
“For example, ICA is currently not available for real-time implementation in EEG and Laplacian montages are ineffective in targeting non-superficial sources like the PCC (Fitzgibbon et al., 2013).”
BackgroundChuang, L.-Y., Huang, C., & Hung, T. (2013) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2013.10.002 · Cited by 131
The advantages of the surface Laplacian in brain–computer interface research
McFarland, D. J. (2014) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2014.07.009 · Cited by 87
“Goncharova et al. (2003) report that surface Laplacians are not effective in reducing EMG contamination while Fitzgibbon et al. (2011) report that they are.”
BackgroundFitzgibbon, S. P., DeLosAngeles, D., Lewis, T. W., Powers, D. M. W., Grummett, T. S., Whitham, E. M., Ward, L. M., Willoughby, J. O., & Pope, K. J. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.12.009 · Cited by 69
Self-citationAnalysis of Gamma-Band Activity from Human EEG Using Empirical Mode Decomposition
Amo, C., de Santiago, L., Barea, R., López-Dorado, A., & Boquete, L. (2017) · Sensors · doi:10.3390/s17050989 · Cited by 80
“In this case, minimum complexity was been achieved using only one electrode.”
MethodBianciardi, B., & Uhlhaas, P. J. (2021) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2021.02.005 · Cited by 59
Dual-process contributions to creativity in jazz improvisations: An SPM-EEG study
Rosen, D. S., Oh, Y., Erickson, B. A., Zhang, F., Kim, Y. E., & Kounios, J. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116632 · Cited by 75
“The Laplacian transformation also has the benefit of suppressing artifacts that have a broad topographic distribution, especially electromyographic artifacts (Fitzgibbon et al., 2013; Muthukumaraswamy, 2013).”
Phadikar, S., Sinha, N., Ghosh, R., & Ghaderpour, E. (2022) · Sensors · doi:10.3390/s22082948 · Cited by 62
Adaptive estimation of hand movement trajectory in an EEG based brain–computer interface system
Robinson, N., Guan, C., & Vinod, A. P. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/6/066019 · Cited by 55
“The muscular artifacts that are present as diffused activity in EEG signals can be removed using spatial fi ltering [ 31 ] .”
MethodUntethered magnetic millirobot for targeted drug delivery
Iacovacci, V., Lucarini, G., Ricotti, L., Dario, P., Dupont, P. E., & Menciassi, A. (2015) · Biomedical Microdevices · doi:10.1007/s10544-015-9962-9 · Cited by 44
On the neural basis of sensory weighting: Alpha, beta and gamma modulations during complex movements
Lebar, N., Danna, J., Moré, S., Mouchnino, L., & Blouin, J. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.02.043 · Cited by 73
“It also allows reducing muscular artifacts (Fitzgibbon et al., 2013), particularly when cortical sources are from relatively small generators (Nunez and Srinivassan, 2006), as is the case for higher-frequency sources (Crone et al., 1998).”
Modulation of Functional EEG Networks by the NMDA Antagonist Nitrous Oxide
Kuhlmann, L., Foster, B. L., & Liley, D. T. J. (2013) · PLoS ONE · doi:10.1371/journal.pone.0056434 · Cited by 42
“The Laplacian also has the advantage of minimizing the electromyographic (EMG) contamination of EEG [43], important given the demonstrated effects of well known anesthetic agents on resting muscle tone [44].”
BackgroundRathee, D., Raza, H., Prasad, G., & Cecotti, H. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2726779 · Cited by 49
“Other published works emphasize on the theoretical perspectives during comparing different referencing schemes or Laplacian filtering methods, with little or no consideration of their impact on BCI performance [35], [36].”
BackgroundMethodThe use of magnetoencephalography in the study of psychopharmacology (pharmaco-MEG)
Muthukumaraswamy, S. D. (2014) · Journal of Psychopharmacology · doi:10.1177/0269881114536790 · Cited by 48
“In fact, a series of studies have shown that even “clean” EEG data in the higher frequency range (gamma-band) can be heavily contaminated with muscle artifacts (Fitzgibbon et al., 2012; Whitham et al., 2007, 2008).”
Fitzgibbon, S. P., DeLosAngeles, D., Lewis, T. W., Powers, D. M. W., Whitham, E. M., Willoughby, J. O., & Pope, K. J. (2014) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2014.10.006 · Cited by 45
Self-citationImproved artefact removal from EEG using Canonical Correlation Analysis and spectral slope
Janani, A. S., Grummett, T. S., Lewis, T. W., Fitzgibbon, S. P., Whitham, E. M., DeLosAngeles, D., Bakhshayesh, H., Willoughby, J. O., & Pope, K. J. (2018) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2018.01.004 · Cited by 43
Self-citationShenoy Handiru, V., Vinod, A. P., & Guan, C. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6baf · Cited by 36
Delta-9-tetrahydrocannabinol, neural oscillations above 20 Hz and induced acute psychosis
Nottage, J. F., Stone, J. M., Murray, R. M., Sumich, A. L., Bramon, E., Ffytche, D. H., & Morrison, P. D. (2014) · Psychopharmacology · doi:10.1007/s00213-014-3684-1 · Cited by 34
“…20 and 27 Hz with THC are difficult to compare directly with previous reports, which do not focus on the same frequency bands, and Böcker and colleagues observed complex, dose-dependent changes in the power of resting ‘beta’ with 29 to 69 mg of smoked THC at mastoid referenced midline electrodes.”
ResultInterference of tonic muscle activity on the EEG: a single motor unit study
Yılmaz, G., Ungan, P., Sebik, O., Uginčius, P., & Türker, K. S. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00504 · Cited by 39
“Similarly, recent paralysis studies confirmed the EMG contamination of EEG (Whitham et al., 2007; Pope et al., 2009; Fitzgibbon et al., 2013).”
BackgroundMethodInduced Gamma-Band Activity during Actual and Imaginary Movements: EEG Analysis
Usanos, C. A., Boquete, L., de Santiago, L., Barea, R., & Cavaliere-Ballesta, C. (2020) · Sensors · doi:10.3390/s20061545 · Cited by 30
“To analyze the GBA, only the Cz channel signals were used, as centrally channels were the least contaminated by movement and EMG artifacts [52].”
MethodKaar, S. J., Nottage, J. F., Angelescu, I., Marques, T. R., & Howes, O. D. (2023) · Clinical EEG and Neuroscience · doi:10.1177/15500594221148643 · Cited by 26
“The signal from central midline electrodes, such as FZ and CZ, has been shown to have a low risk of electromyogenic (EMG) contamination, 88 and only strong muscle contraction gives rise to contamination at these locations.”
BackgroundVariability and stability of large-scale cortical oscillation patterns
Cox, R., Schapiro, A. C., & Stickgold, R. (2018) · Network Neuroscience · doi:10.1162/netn_a_00046 · Cited by 28
“However, muscle activity is severely attenuated by the surface Laplacian transform (Fitzgibbon et al., 2013), and skull thickness contributes minimally to the scalp EEG (Hagemann, Hewig, Walter, & Naumann, 2008), making it unlikely these factors underlie the reported between-subject variability.”
Assessment of mental workload by EEG+FNIRS
Aghajani, H., & Omurtag, A. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591549 · Cited by 23
“Spatial Laplacian transform is very effective in muscle artifact removal from EEG signal [20].”
BackgroundMethodCodina, T., Blankertz, B., & von Lühmann, A. (2025) · Imaging Neuroscience · doi:10.1162/imag.a.974 · Cited by 30
“…and its variants (60 articles), used for reducing the effect of cardiac, ocular, and muscular confounding signals, followed by other EOG-regression algorithms, Laplacian filtering for muscle contamination ( Fitzgibbon et al., 2013), and Artifact Sub-space Reconstruction (ASR) ( Chang et al., 2020).”
Pitfalls in Scalp High-Frequency Oscillation Detection From Long-Term EEG Monitoring
Gerner, N., Thomschewski, A. C., Marcu, A., Trinka, E., & Höller, Y. (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.00432 · Cited by 20
Assessing EEG sleep spindle propagation. Part 1: Theory and proposed methodology
O’Reilly, C., & Nielsen, T. (2013) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2013.08.013 · Cited by 20
“The Laplacian montage is noted for removing volume conduction effects (Bortel and Sovka, 2013) and muscular artifacts (Fitzgibbon et al., 2013) but also scrambles phase differences (Thatcher, 2012).”
BackgroundMovement related cortical potentials in severe chronic stroke
Yilmaz, O., Cho, W., Braun, C., Birbaumer, N., & Ramos-Murguialday, A. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2013.6609976 · Cited by 19
“Using these surface Laplacian methods like CSD we decreased the contribution of the muscle artifacts to the signal significantly [18], which is one of the main problems with these patients tending to evoke movement compensation.”
MethodPope, K. J., Lewis, T. W., Fitzgibbon, S. P., Janani, A. S., Grummett, T. S., Williams, P. A. H., Battersby, M., Bastiampillai, T. J., Whitham, E. M., & Willoughby, J. O. (2022) · Brain and Behavior · doi:10.1002/brb3.2721 · Cited by 18
Self-citationAn Overview of EEG Seizure Detection Units and Identifying their Complexity- A Review
Rajendran, T., & Sridhar, K. P. (2018) · Current Signal Transduction Therapy · doi:10.2174/1574362413666181030103616 · Cited by 11
Janani, A. S., Grummett, T. S., Lewis, T. W., Fitzgibbon, S. P., Whitham, E. M., DeLosAngeles, D., Bakhshayesh, H., Willoughby, J. O., & Pope, K. J. (2017) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2017.06.011 · Cited by 9
Self-citationBasics of Electroencephalography for Neuropsychiatrist
Eun, H. J. (2019) · 신경정신의학 · doi:10.4306/jknpa.2019.58.2.76 · Cited by 11
Commentary: Enhanced Interplay of Neuronal Coherence and Coupling in the Dying Human Brain
Greyson, B., van Lommel, P., & Fenwick, P. B. C. (2022) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2022.899491 · Cited by 14
“Contamination of EEG recordings by muscle artifact is a wellrecognized problem, especially in the high-frequency gamma range, leading to erroneous estimates of EEG spectral power and coherence (Goncharova et al., 2003; Pope et al., 2009; Fitzgibbon et al., 2013).”
BackgroundAn overview of electroencephalogram based human-computer interface
Hasan, M. M., Aris, S. A. M., & Sulaiman, N. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-29150-0.00018-4 · Cited by 8
The surface Laplacian technique in EEG: Theory and methods
Carvalhaes, C. G., & de Barros, J. A. (2015) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2015.04.023 · Cited by 39
“, 2007), high-frequency EEG (Fitzgibbon et al., 2013), and brain–computer interface (Lu et al.”
BackgroundMethodInfluentialMovement related cortical potentials change after EEG-BMI rehabilitation in chronic stroke
Yilmaz, Ö., Oladazimi, M., Cho, W., Brasil, F. L., Curado, M. R., Cossio, E. G., Braun, C., Birbaumer, N., & Ramos‐Murguialday, A. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6695874 · Cited by 6
“Using these surface Laplacian methods like CSD decreases the contribution of the muscle artifacts to the signal [16], which is one of the main problems with the patients tending to evoke movement compensation.”
MethodContributions of action potentials to scalp EEG: Theory and biophysical simulations
Brake, N., & Khadra, A. (2025) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1012794 · Cited by 5
“This was done be analyzing the EEG data that Whitham et al. [20] collected from subjects during peripheral blockade of nicotinic cholinergic receptors, which causes muscle paralysis and attenuates myogenic artifacts [20,22].”
Shaikh, U. Q., Kalra, A., Lowe, A., & Niazi, I. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae541d · Cited by 5
“These include wavelet-based approaches [38–41], surface Laplacian transforms [42], morphological component analysis [43], empirical mode decomposition (EMD) and its variants such as ensemble EMD (EEMD) and complete EMD with adaptive noise (CEEMDAN) [44–49], variational mode decomposition (VMD)…”
Kalra, A. M., Anand, G., & Lowe, A. (2020) · Modern Applied Science · doi:10.5539/mas.v14n6p47 · Cited by 3
Porr, B., & Bohollo, L. M. (2023) · PLoS ONE · doi:10.1371/journal.pone.0290446 · Cited by 2
“Be it P300 or ICA they are in stark contrast to determining the SNR by paralysing a participant temporarily [15, 17] which would certainly yield the best results but no doubt would raise substantial ethical concerns.”
BackgroundMartin, J., Liley, D. T. J., Beer, C. F. L. A., & Davidson, A. J. (2024) · Anesthesiology · doi:10.1097/aln.0000000000004902 · Cited by 3
“34 This montage mitigates volume conduction, enhancing electrode sensitivity to local and superficial cortical activity.”
BackgroundAdabook and Multibook - Adaptive Boosting with Chance Correction
Powers, D. M. W. (2013) · International Conference on Informatics in Control, Automation and Robotics (ICINCO) · doi:10.5220/0004416303490359 · Cited by 2
“The practical context of the work reported here, including the development and testing of the various chance-corrected measures, is signal processing of Electroencephalographic Brain Computer Interface experiments [15,16,17], Audiovisual Speech, Gesture, Expression and Emotion Recognition [18,19,20], and Information R…”
MethodSelf-citationTiming of Speech in Brain and Glottis and the Feedback Delay Problem in Motor Control
Veillette, J. P., Rosen, J., Margoliash, D., & Nusbaum, H. C. (2025) · Journal of Neuroscience · doi:10.1523/jneurosci.2294-24.2025 · Cited by 1
A survey of methods for the construction of a Brain Computer Interface
Abdallah, N., Khawandi, S., Daya, B., & Chauvet, P. E. (2017) · Sensors Networks Smart and Emerging Technologies (SENSET) · doi:10.1109/senset.2017.8125005 · Cited by 1
“d) SL: According to [12], Scalp surface Laplacian transforms are more efficient than CAR methods in the reduction of muscle power artifacts.”
MethodCortical surface recurrent brain-computer interfaces
Zanos, S. P. (2013) · ResearchWorks at the University of Washington (University of Washington) · Cited by 3
Handiru, V. S. (2018) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/73334 · Cited by 1
“Subsequently, the local Surface Laplacian filter was applied to the data as it is found to be robust in separating out muscle artifacts [177].”
MethodHasegawa, S., Aoki, Y., Wada, S., Ueno, A., Cauwenberghs, G., Fukuoka, Y., Shimizu, Y., Nishimura, N., & Iwase, S. (2013) · E-Health and Bioengineering Conference (EHB) · doi:10.1109/ehb.2013.6707284
“when an electrode is placed appropriately above a target nerve fascicle, the signal obtained with a concentric bipolar electrode is less susceptible to interferences caused by the activity of neighboring muscles than a conventional body surface electrode [7].”
BackgroundHow many features does it take to change a lightbulb
Powers, D. M. W. (2013) · eScholarship (California Digital Library)
Self-citationQuantitative analysis of epileptic and meditation EEG signals
Jing, J. (2016) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/68880
Blood Velocity Estimation Based on an Optimal Observer for Magnetic Nanorobots Navigation
Duc, T. (2017) · MATEC Web of Conferences · doi:10.1051/matecconf/201710805002
ADABOOK & MULTIBOOK: Adaptive Boosting with Chance CorrectionPreprint
Powers, D. M. W. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2010.15550
Self-citationToropova, A., & Simakova, I. (2021) · Current Research in Systematic Musicology · doi:10.1007/978-3-030-85886-5_6
2013 Index IEEE Transactions on Biomedical Engineering Vol. 60
(2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2295159
Metadata
- Authors
- Fitzgibbon, S. P., Lewis, T. W., Powers, D. M. W., Whitham, E. W., Willoughby, J. O., & Pope, K. J.
- Affiliations
- Flinders University (AU)
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2013-01
- Volume
- 60
- Issue
- 1
- Pages
- 4-9
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W1964964988
- Cited by
- 67
- References
- 21
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 2 · 2023: 2 · 2022: 3 · 2021: 2 · 2020: 7 · 2019: 3 · 2018: 6 · 2017: 10 · 2016: 4 · 2015: 5 · 2014: 6 · 2013: 12
- FWCI
- 3.93
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Flinders Academic Commons (Flinders University) (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- EEG signal processing, muscle artifacts, neuromuscular blockade, common average reference, gamma oscillations
- MeSH terms
- Adult, Aged, Electroencephalography, Electromyography, Evoked Potentials, Visual, Female, Humans, Male, Middle Aged, Scalp, Signal Processing, Computer-Assisted, Task Performance and Analysis, Muscle, Skeletal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.