Developing an Effective Arterial Stiffness Monitoring System Using the Spring Constant Method and Photoplethysmography
The DOI matches its Crossref record.
Abstract
This study aimed to develop a fast and effective arterial stiffness monitoring system for diabetic patients using the spring constant method and photoplethysmography (PPG). The experimental group comprised 70 patients (4 type 1 diabetes mellitus patients and 66 type 2 diabetes mellitus patients); 23 participants suffered from atherosclerosis. All were subjected to the measurements of both the carotid-femoral pulse wave velocity (cfPWV) and the spring constants evaluated using the PPG pulse as well as the radial pulse. The control group comprised 70 normal participants (39 men and 31 women) who did not have diabetes mellitus, with an age range of 40-84 years. All control group members were only subjected to the measurement by the spring constant method. For the experimental group, statistical analysis indicated a significantly high correlation between the spring constants computed using PPG and the radial pulse (p < 0.001, correlation coefficient =0.89). The result also showed a significant negative correlation between the cfPWV and the spring constant of PPG (p < 0.001, correlation coefficient = - 0.72); multivariate analysis similarly indicated a close relationship. In addition, we used Student's t test to examine the difference between the experimental and control groups for the spring constant of PPG. A P value less than 0.05 confirmed that the difference between the two groups was statistically significant. In the receiver operating characteristic curve, area under curve (=0.82) indicates a good discrimination, and a spring constant of PPG below 516 (g/s (2)) may imply a risk of arterial stiffness for diabetic patients. These findings imply that the spring constant of PPG could effectively identify normal versus abnormal characteristics of elasticity in normal and diabetic participants. As a result of some excellent characteristics in clinical monitoring, the spring constant computed using PPG shows the effectiveness and feasibility in the monitoring system of arterial stiffness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Charlton, P. H., Mariscal Harana, J., Vennin, S., Li, Y., Chowienczyk, P., & Alastruey, J. (2019) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00218.2019 · Cited by 256
Photoplethysmography signal processing and synthesis
Mejía-Mejía, E., Allen, J., Budidha, K., El-Hajj, C., Kyriacou, P. A., & Charlton, P. H. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00015-3 · Cited by 138
“Combined multiple IPAD inflection point area plus d-peak, (A2/A1) + d/a [112] Amplitudes k spring constant, x′′(s)/((x(sys) − x(ms))/(x(sys) − x(0))) [119]”
BackgroundAssessing mental stress from the photoplethysmogram: a numerical study
Charlton, P. H., Celka, P., Farukh, B., Chowienczyk, P., & Alastruey, J. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aabe6a · Cited by 131
Photoplethysmography signal analysis to assess obesity, age group and hypertension
Ferdinando, H., Huotari, M., & Myllyla, T. (2019) · 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857570 · Cited by 9
“Several attempts have been made to use PPG signals to estimate blood pressure using the PPG signals [1]–[5] and arterial stiffness [6]–[8].”
Metadata
- Authors
- Wei, C.-C.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2013-01
- Volume
- 60
- Issue
- 1
- Pages
- 151-154
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2095249499
- Cited by
- 37
- References
- 0
- FWCI
- 0.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Developing an Effective Arterial Stiffness Monitoring System Using the Spring Constant Method and Photoplethysmography. https://app.cochat.ai/papers/10.1109/tbme.2012.2207384
- The paper
- Wei, C.-C. (2013). Developing an Effective Arterial Stiffness Monitoring System Using the Spring Constant Method and Photoplethysmography. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2012.2207384
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.