The DOI matches its Crossref record; 148 of the 148 references it cites were found in a registry or an index.
Modeling arterial pulse waves in healthy aging: a database for in silico evaluation of hemodynamics and pulse wave indexes
Open accessAbstract
The arterial pulse wave (PW) is a rich source of information on cardiovascular (CV) health. It is widely measured by both consumer and clinical devices. However, the physical determinants of the PW are not yet fully understood, and the development of PW analysis algorithms is limited by a lack of PW data sets containing reference CV measurements. Our aim was to create a database of PWs simulated by a computer to span a range of CV conditions, representative of a sample of healthy adults. The typical CV properties of 25–75 yr olds were identified through a literature review. These were used as inputs to a computational model to simulate PWs for subjects of each age decade. Pressure, flow velocity, luminal area, and photoplethysmographic PWs were simulated at common measurement sites, and PW indexes were extracted. The database, containing PWs from 4,374 virtual subjects, was verified by comparing the simulated PWs and derived indexes with corresponding in vivo data. Good agreement was observed, with well-reproduced age-related changes in hemodynamic parameters and PW morphology. The utility of the database was demonstrated through case studies providing novel hemodynamic insights, in silico assessment of PW algorithms, and pilot data to inform the design of clinical PW algorithm assessments. In conclusion, the publicly available PW database is a valuable resource for understanding CV determinants of PWs and for the development and preclinical assessment of PW analysis algorithms. It is particularly useful because the exact CV properties that generated each PW are known. NEW & NOTEWORTHY First, a comprehensive literature review of changes in cardiovascular properties with age was performed. Second, an approach for simulating pulse waves (PWs) at different ages was designed and verified against in vivo data. Third, a PW database was created, and its utility was illustrated through three case studies investigating the determinants of PW indexes. Fourth, the database and tools for creating the database, analyzing PWs, and replicating the case studies are freely available.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smoothing and Differentiation of Data by Simplified Least Squares Procedures.
Savitzky, A., & Golay, M. J. E. (1964) · Analytical Chemistry · doi:10.1021/ac60214a047 · Cited by 21,904
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
The Reference Values for Arterial Stiffness' Collaboration (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq165 · Cited by 2,087
Mitchell, G. F., Parise, H., Benjamin, E. J., Larson, M. G., Keyes, M. J., Vita, J. A., Vasan, R. S., & Levy, D. (2004) · Hypertension · doi:10.1161/01.hyp.0000128420.01881.aa · Cited by 1,501
Normal Vascular Aging: Differential Effects on Wave Reflection and Aortic Pulse Wave Velocity
McEniery, C. M., Yasmin, Hall, I. R., Qasem, A., Wilkinson, I. B., & Cockcroft, J. R. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.07.037 · Cited by 1,359
Mechanical Factors in Arterial Aging
O’Rourke, M. F., & Hashimoto, J. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.12.050 · Cited by 1,250
Systolic Time Intervals in Heart Failure in Man
WEISSLER, A. M., HARRIS, W. S., & SCHOENFELD, C. D. (1968) · Circulation · doi:10.1161/01.cir.37.2.149 · Cited by 1,217
Pauca, A. L., O’Rourke, M. F., & Kon, N. D. (2001) · Hypertension · doi:10.1161/hy1001.096106 · Cited by 1,179
Noninvasive determination of age-related changes in the human arterial pulse.
Kelly, R., Hayward, C., Avolio, A., & O'Rourke, M. (1989) · Circulation · doi:10.1161/01.cir.80.6.1652 · Cited by 1,141
Effects of age and aerobic capacity on arterial stiffness in healthy adults.
Vaitkevicius, P. V., Fleg, J. L., Engel, J. H., O'Connor, F. C., Wright, J. G., Lakatta, L. E., Yin, F. C., & Lakatta, E. G. (1993) · Circulation · doi:10.1161/01.cir.88.4.1456 · Cited by 1,083
Research works printed but not linked: 26
- 10.1080/10255840600985477 · doi:10.1080/10255840600985477
- Boss GR, 1981, West J Med, 135, 434
- Bramwell JC, 1923, Heart, 10, 233
- 10.1016/j.artres.2018.10.217 · doi:10.1016/j.artres.2018.10.217
- 10.1038/s41371-018-0109-3 · doi:10.1038/s41371-018-0109-3
- 10.1109/EMBC.2014.6944441 · doi:10.1109/embc.2014.6944441
- Charlton PH, 2018, BioMedEng18 Conference, 114
- Charlton PH, 2018, 8th World Congress of Biomechanic, 1396
- 10.1007/s10439-011-0487-y · doi:10.1007/s10439-011-0487-y
- 10.1161/01.CIR.2.6.915 · doi:10.1161/01.cir.2.6.915
- 10.1016/0002-9149(68)90207-5 · doi:10.1016/0002-9149(68)90207-5
- 10.1113/jphysiol.1930.sp002658 · doi:10.1113/jphysiol.1930.sp002658
- 10.1152/jappl.1974.36.4.407 · doi:10.1152/jappl.1974.36.4.407
- 10.1007/BF02442802 · doi:10.1007/bf02442802
- 10.1007/s11012-015-0283-0 · doi:10.1007/s11012-015-0283-0
- Kharb S, 1999, J Assoc Physicians India, 47, 505
- 10.1093/geronj/13.2.153 · doi:10.1093/geronj/13.2.153
- 10.1007/BF02608853 · doi:10.1007/bf02608853
- Medical Services Advisory Committee, 2006, Peripheral Arterial Tonometry with Ascending Aortic Waveform Analysis Using the SphygmoCor System
- 10.1016/0741-5214(93)90161-E · doi:10.1016/0741-5214(93)90161-e
- 10.1016/0002-8703(72)90218-9 · doi:10.1016/0002-8703(72)90218-9
- 10.1093/geronj/28.2.133 · doi:10.1093/geronj/28.2.133
- 10.1161/01.ATV.3.3.199 · doi:10.1161/01.atv.3.3.199
- Sun JX, 2005, Comput Cardiol, 32, 295, 10.1109/CIC.2005.1588095 · doi:10.1109/cic.2005.1588095
- Ushiroyama T, 2005, Bull Osaka Med Coll, 51, 76
- Virmani R, 1991, Am J Pathol, 139, 1119
Cited by
Wearable Photoplethysmography for Cardiovascular Monitoring
Charlton, P. H., Kyriacou, P. A., Mant, J., Marozas, V., Chowienczyk, P., & Alastruey, J. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3149785 · Cited by 250
Self-citationPhotoplethysmography signal processing and synthesis
Mejía-Mejía, E., Allen, J., Budidha, K., El-Hajj, C., Kyriacou, P. A., & Charlton, P. H. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00015-3 · Cited by 138
Self-citation
Metadata
- Authors
- Charlton, P. H., Mariscal Harana, J., Vennin, S., Li, Y., Chowienczyk, P., & Alastruey, J.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2019-11-01
- Volume
- 317
- Issue
- 5
- Pages
- H1062-H1085
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2969170900
- Cited by
- 256
- References
- 148
- FWCI
- 13.20
- Type
- journal article
- Language
- en
- Open access
- hybrid
- Funders
- British Heart Foundation (PG/15/104/31913)
- Wellcome Trust (WT 203148/Z/16/Z)
- Engineering and Physical Sciences Research Council (WT 203148/Z/16/Z)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Modeling arterial pulse waves in healthy aging: a database for in silico evaluation of hemodynamics and pulse wave indexes. https://app.cochat.ai/papers/10.1152/ajpheart.00218.2019
- The paper
- Charlton, P. H., Mariscal Harana, J., Vennin, S., Li, Y., Chowienczyk, P., & Alastruey, J. (2019). Modeling arterial pulse waves in healthy aging: a database for in silico evaluation of hemodynamics and pulse wave indexes. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.00218.2019
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.