Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 256

The DOI matches its Crossref record; 148 of the 148 references it cites were found in a registry or an index.

Modeling arterial pulse waves in healthy aging: a database for in silico evaluation of hemodynamics and pulse wave indexes

Open access
Charlton, Peter H., Mariscal Harana, Jorge, Vennin, Samuel, Li, Ye, Chowienczyk, Phil, Alastruey, Jordi·2019·American Journal of Physiology-Heart and Circulatory Physiology

Abstract

The arterial pulse wave (PW) is a rich source of information on cardiovascular (CV) health. It is widely measured by both consumer and clinical devices. However, the physical determinants of the PW are not yet fully understood, and the development of PW analysis algorithms is limited by a lack of PW data sets containing reference CV measurements. Our aim was to create a database of PWs simulated by a computer to span a range of CV conditions, representative of a sample of healthy adults. The typical CV properties of 25–75 yr olds were identified through a literature review. These were used as inputs to a computational model to simulate PWs for subjects of each age decade. Pressure, flow velocity, luminal area, and photoplethysmographic PWs were simulated at common measurement sites, and PW indexes were extracted. The database, containing PWs from 4,374 virtual subjects, was verified by comparing the simulated PWs and derived indexes with corresponding in vivo data. Good agreement was observed, with well-reproduced age-related changes in hemodynamic parameters and PW morphology. The utility of the database was demonstrated through case studies providing novel hemodynamic insights, in silico assessment of PW algorithms, and pilot data to inform the design of clinical PW algorithm assessments. In conclusion, the publicly available PW database is a valuable resource for understanding CV determinants of PWs and for the development and preclinical assessment of PW analysis algorithms. It is particularly useful because the exact CV properties that generated each PW are known. NEW & NOTEWORTHY First, a comprehensive literature review of changes in cardiovascular properties with age was performed. Second, an approach for simulating pulse waves (PWs) at different ages was designed and verified against in vivo data. Third, a PW database was created, and its utility was illustrated through three case studies investigating the determinants of PW indexes. Fourth, the database and tools for creating the database, analyzing PWs, and replicating the case studies are freely available.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.00218.2019

Cites

148 of 148 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 148 references

Research works printed but not linked: 26

  1. 10.1080/10255840600985477 · doi:10.1080/10255840600985477
  2. Boss GR, 1981, West J Med, 135, 434
  3. Bramwell JC, 1923, Heart, 10, 233
  4. 10.1016/j.artres.2018.10.217 · doi:10.1016/j.artres.2018.10.217
  5. 10.1038/s41371-018-0109-3 · doi:10.1038/s41371-018-0109-3
  6. 10.1109/EMBC.2014.6944441 · doi:10.1109/embc.2014.6944441
  7. Charlton PH, 2018, BioMedEng18 Conference, 114
  8. Charlton PH, 2018, 8th World Congress of Biomechanic, 1396
  9. 10.1007/s10439-011-0487-y · doi:10.1007/s10439-011-0487-y
  10. 10.1161/01.CIR.2.6.915 · doi:10.1161/01.cir.2.6.915
  11. 10.1016/0002-9149(68)90207-5 · doi:10.1016/0002-9149(68)90207-5
  12. 10.1113/jphysiol.1930.sp002658 · doi:10.1113/jphysiol.1930.sp002658
  13. 10.1152/jappl.1974.36.4.407 · doi:10.1152/jappl.1974.36.4.407
  14. 10.1007/BF02442802 · doi:10.1007/bf02442802
  15. 10.1007/s11012-015-0283-0 · doi:10.1007/s11012-015-0283-0
  16. Kharb S, 1999, J Assoc Physicians India, 47, 505
  17. 10.1093/geronj/13.2.153 · doi:10.1093/geronj/13.2.153
  18. 10.1007/BF02608853 · doi:10.1007/bf02608853
  19. Medical Services Advisory Committee, 2006, Peripheral Arterial Tonometry with Ascending Aortic Waveform Analysis Using the SphygmoCor System
  20. 10.1016/0741-5214(93)90161-E · doi:10.1016/0741-5214(93)90161-e
  21. 10.1016/0002-8703(72)90218-9 · doi:10.1016/0002-8703(72)90218-9
  22. 10.1093/geronj/28.2.133 · doi:10.1093/geronj/28.2.133
  23. 10.1161/01.ATV.3.3.199 · doi:10.1161/01.atv.3.3.199
  24. Sun JX, 2005, Comput Cardiol, 32, 295, 10.1109/CIC.2005.1588095 · doi:10.1109/cic.2005.1588095
  25. Ushiroyama T, 2005, Bull Osaka Med Coll, 51, 76
  26. Virmani R, 1991, Am J Pathol, 139, 1119

Cited by

See all 256

Metadata

Authors
Charlton, P. H., Mariscal Harana, J., Vennin, S., Li, Y., Chowienczyk, P., & Alastruey, J.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
2019-11-01
Volume
317
Issue
5
Pages
H1062-H1085
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W2969170900
Cited by
256
References
148
FWCI
13.20
Type
journal article
Language
en
Open access
hybrid
Funders
  • British Heart Foundation (PG/15/104/31913)
  • Wellcome Trust (WT 203148/Z/16/Z)
  • Engineering and Physical Sciences Research Council (WT 203148/Z/16/Z)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Modeling arterial pulse waves in healthy aging: a database for in silico evaluation of hemodynamics and pulse wave indexes. https://app.cochat.ai/papers/10.1152/ajpheart.00218.2019
The paper
Charlton, P. H., Mariscal Harana, J., Vennin, S., Li, Y., Chowienczyk, P., & Alastruey, J. (2019). Modeling arterial pulse waves in healthy aging: a database for in silico evaluation of hemodynamics and pulse wave indexes. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.00218.2019

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.