Photoplethysmography signal analysis to assess obesity, age group and hypertension
Abstract
Photoplethysmography (PPG) provides a simple, convenient and noninvasive method to assess pulse oximetry. Several attempts have been made to use PPG also to estimate blood pressure and arterial stiffness. This paper attempts to assess obesity classes, age group, and hypertension classes using PPG measured from the finger. One set of features was derived from the normalized pulse width of PPG and the other from original PPG. The features were calculated based on the pulse decomposition analysis using five lognormal functions and the up-slope of the PPG pulse. Using kNN and SVM as classifiers, the results were validated using leave-one-out validation. Performances of both features sets have no significant difference, and the kNN outperformed the SVM. The best accuracies are 93%, 88%, and 92% for obesity (5 classes), age group (7 classes), and hypertension (4 classes) respectively. These three assessment targets have a strong relationship with arterial stiffness, therefore it also leads to a study about arterial stiffness using PPG. Width normalization to 1 second might affect some features points based on pulse decomposition analysis. This study also found that the up-slope analysis might give good indices when width normalization was employed. However, these findings still require more experiments to gain conclusions that are more comprehensive.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Ferdinando et al. were able to identify five classes of obesity from PPG waveforms using 17 parameters derived from the decomposition of the PPG waveform into five lognormal functions.
“Using k-nearest neighbor and support vector machines, Ferdinando et al. were able to identify five classes of obesity from PPG waveforms using 17 parameters derived from the decomposition of the PPG waveform into five lognormal functions.”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [76]
Cites
Rapsomaniki, E., Timmis, A., George, J., Pujades-Rodriguez, M., Shah, A. D., Denaxas, S., White, I. R., Caulfield, M. J., Deanfield, J. E., Smeeth, L., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(14)60685-1 · Cited by 1,643 · see citing works
On the Analysis of Fingertip Photoplethysmogram Signals
Elgendi, M. (2012) · Current Cardiology Reviews · doi:10.2174/157340312801215782 · Cited by 1,206 · see citing works
Lee, H., & Oh, B. (2010) · Circulation Journal · doi:10.1253/circj.cj-10-0910 · Cited by 624 · see citing works
Takazawa, K., Tanaka, N., Fujita, M., Matsuoka, O., Saiki, T., Aikawa, M., Tamura, S., & Ibukiyama, C. (1998) · Hypertension · doi:10.1161/01.hyp.32.2.365 · Cited by 589 · see citing works
Aging, Arterial Stiffness and Hypertension
Sun, Z.-J. (2014) · HYPERTENSION · doi:10.1161/hypertensionaha.114.03617 · Cited by 545 · see citing works
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J. W., Hill, M. N., Jones, D. W., Kurtz, T. W., Sheps, S. G., & Roccella, E. J. (2005) · Journal of Clinical Hypertension · doi:10.1111/j.1524-6175.2005.04377.x · Cited by 435 · see citing works
Optical blood pressure estimation with photoplethysmography and FFT-based neural networks
Xing, X., & Sun, M. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.003007 · Cited by 263 · see citing works
Blood pressure estimation from appropriate and inappropriate PPG signals using A whole-based method
Mousavi, S. S., Firouzmand, M., Charmi, M., Hemmati, M. R., Moghadam, M., & Ghorbani, Y. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.08.022 · Cited by 234 · see citing works
A new, short-recorded photoplethysmogram dataset for blood pressure monitoring in China
Liang, Y., Chen, Z., Liu, G., & Elgendi, M. (2018) · Scientific Data · doi:10.1038/sdata.2018.20 · Cited by 215 · see citing works
von Wowern, E., Östling, G., Nilsson, P. M., & Olofsson, P. (2015) · PLOS ONE · doi:10.1371/journal.pone.0135659 · Cited by 134 · cited 1× · see citing works
“Several attempts have been made to use PPG signals to estimate blood pressure using the PPG signals [1]–[5] and arterial stiffness [6]–[8].”
Nordstrand, N., Gjevestad, E. S., Dinh, K., Hofsø, D., Røislien, J., Saltvedt, E., Os, I., & Hjelmesaeth, J. S. (2011) · BMC Cardiovascular Disorders · doi:10.1186/1471-2261-11-7 · Cited by 81 · see citing works
Wen, W., Luo, R., Tang, X., et al. (2014) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2014.10.089 · Cited by 79 · see citing works
Assessment of cardiovascular function from multi-Gaussian fitting of a finger photoplethysmogram
Couceiro, R., Carvalho, P., Paiva, R. P., Henriques, J. M. O., Quintal, I., Antunes, M., Muehlsteff, J., Eickholt, C., Brinkmeyer, C., Kelm, M., et al. (2015) · Physiological Measurement · doi:10.1088/0967-3334/36/9/1801 · Cited by 70 · see citing works
Photoplethysmographic signal waveform index for detection of increased arterial stiffness
Pilt, K., Meigas, K., Ferenets, R., Temitski, K., & Viigimaa, M. (2014) · Physiological Measurement · doi:10.1088/0967-3334/35/10/2027 · Cited by 62 · see citing works
Association of body mass index with arterial stiffness and blood pressure components: A twin study
Tárnoki, Á. D., Tárnoki, D. L., Bogl, L. H., Medda, E., Fagnani, C., Nisticò, L., Stazi, M. A., Brescianini, S., Lucatelli, P., Boatta, E., et al. (2013) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2013.05.001 · Cited by 45 · see citing works
Wei, C.-C. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2207384 · Cited by 37 · see citing works
A new method to estimate arterial blood pressure using photoplethysmographic signal
Jeong, I. C., Ko, J. I., Hwang, S. O., & Yoon, H. R. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260663 · Cited by 24 · see citing works
Non-invasive Studies on Age Related Parameters Using a Blood Volume Pulse Sensor
Jayasree, V. K., Sandhya, T., & Radhakrishnan, P. (2008) · Measurement Science Review · doi:10.2478/v10048-008-0020-0 · Cited by 23 · see citing works
Estimation of blood pressure using Photoplethysmography on the wrist
Song, S., Cho, J., Oh, H. S., Lee, J., & Iy, K. (2009) · Computers in Cardiology Conference · Cited by 21 · see citing works
Removal of Pulse Waveform Baseline Drift Using Cubic Spline Interpolation
Yang, L., Zhang, S., Li, X., et al. (2010) · International Conference on Bioinformatics and Biomedical Engineering · doi:10.1109/icbbe.2010.5516523 · Cited by 18 · see citing works
Momin, M., Li, J., Zhang, Y., Fan, F., Xu, X., Xu, X. P., Wang, B., Yang, W., Xie, L., & Huo, Y. (2017) · Clinical and Experimental Hypertension · doi:10.1080/10641963.2016.1254226 · Cited by 12 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348 · see citing works
- Authors
- Ferdinando, H., Huotari, M., & Myllyla, T.
- Affiliations
- Petra Christian University (ID)
- University of Oulu (FI)
- ORCID
- Ferdinando, Hany
- Venue
- 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Publisher
- IEEE
- Published
- 2019-07
- Volume
- 2019
- Pages
- 5572-5575
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2979702794
- Cited by
- 9
- References
- 21
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 2 · 2023: 2 · 2021: 1 · 2020: 2
- FWCI
- 1.56
- Type
- conference paper
- Language
- en
- Open access
- closed
- Licence
- Locations
- Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- photoplethysmography, obesity classification, hypertension classification, pulse decomposition, finger PPG, k-nearest neighbors, support vector machine
- MeSH terms
- Humans, Hypertension, Obesity, Oximetry, Signal Processing, Computer-Assisted, Photoplethysmography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review