P300-Based Brain-Neuronal Computer Interaction for Spelling Applications
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
A brain-neuronal computer interaction system can provide a communication channel for severely disabled people or a supplementary control channel for able-bodied subjects. In this paper, a physiological hybrid P300-based speller that uses a modified stimulus presentation paradigm-the half checkerboard paradigm (HCBP)-is evaluated. The speller uses electrooculography and electroencephalography signals for selecting alphanumeric characters or commands arranged in an 8 × 9 matrix. In this study a group of subjects, who can voluntarily gaze at a target, used the checkerboard paradigm- and HCBP-based spellers in a counterbalanced fashion for comparing their performances under a series of online tests. A 16-character-long text was spelled by each subject, while a 13-character-long text was used for calibrating the system. By using the HCBP, the time required for spelling one character is reduced, resulting in higher information transfer rates. The results suggest that the HCBP has the potential to provide a more effective P300 paradigm with a major importance for people with neuromuscular diseases and also for healthy people as a supplementary communication channel.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228 · cited 2×
“The P300 ERP has been widely used in spelling applications [20], [26], [47], for environmental control [18] or Internet browser”
MethodEvoked-potential correlates of stimulus uncertainty
Sutton, S., Braren, M., Zubin, J., & John, E. R. (1965) · Science · doi:10.1126/science.150.3700.1187 · Cited by 3,061
Toward enhanced p300 speller performance
Krusienski, D. J., Sellers, E. W., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.07.017 · Cited by 749 · cited 1×
“to the 10/20 extended International System [1], were used for recording the EEG signals, since most of the P300 energy in BCI applications is captured at these locations [23], [31], [43], [47].”
MethodHow many people are able to control a P300-based brain-computer interface (BCI)?
Guger, C., Daban, S., Sellers, E., Holzner, C., Krausz, G., Carabalona, R., Gramatica, F., & Edlinger, G. (2009) · Neuroscience Letters · doi:10.1016/j.neulet.2009.06.045 · Cited by 652 · cited 7×
“Items are organized in rows and columns (rowcolumn paradigm, or RCP) being intensified in a random order, which constitutes an " odd-ball " paradigm.”
BackgroundMethodInfluentialTownsend, G., LaPallo, B. K., Boulay, C. B., Krusienski, D. J., Frye, G. E., Hauser, C. K., Schwartz, N. E., Vaughan, T. M., Wolpaw, J. R., & Sellers, E. W. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.030 · Cited by 570 · cited 10×
“68 selections/min in [47], while the HCBP achieved a higher number of 5.”
BackgroundMethodInfluentialLeeb, R., Sagha, H., Chavarriaga, R., & Millán, J. D. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025011 · Cited by 242
Combining eye gaze input with a brain–computer interface for touchless human–computer interaction
Zander, T. O., Gaertner, M., Kothe, C., & Vilimek, R. (2010) · International Journal of Human–Computer Interaction · doi:10.1080/10447318.2011.535752 · Cited by 143 · cited 1×
“Furthermore, in the context of hBCIs combinations of EEG and EMG [32], [33] or eye gaze and BCIs [49], [53] have been proposed.”
Background
Cited by
Brain–Computer Interface Spellers: A Review
Rezeika, A., Benda, M., Stawicki, P., Gembler, F., Saboor, A., & Volosyak, I. (2018) · Brain Sciences · doi:10.3390/brainsci8040057 · Cited by 391
EEG source imaging enhances the decoding of complex right-hand motor imagery tasks
Edelman, B. J., Baxter, B., & He, B. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2467312 · Cited by 370
Noninvasive Brain-Computer Interfaces Based on Sensorimotor Rhythms
He, B., Baxter, B., Edelman, B. J., Cline, C. C., & Ye, W. W. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2407272 · Cited by 233
“Past BCI research has primarily focused on the communication aspect with spelling systems utilizing P300 responses [28]–[31], SSVEPs [32]– [35], and sensorimotor-rhythms (SMRs) [19], [36], [37].”
A High Performance Spelling System based on EEG-EOG Signals With Visual Feedback
Lee, M.-H., Williamson, J., Won, D.-O., Fazli, S., & Lee, S.-W. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2839116 · Cited by 163
“Similar approaches where the visual stimulus were divided into a number of sections with the EOG and EEG modalities used to classify the target section and the symbol, respectively, have been proposed based on the dual-monitor [25] and half checkerboard paradigms [23].”
MethodAghili, S. N., & Erfanian, A. (2023) · IEEE Access · doi:10.1109/access.2023.3313260 · Cited by 12
“required a longer time to spell a character [32].”
BackgroundInfluential
Metadata
- Authors
- Postelnicu, C.-C., & Talaba, D.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2013-02
- Volume
- 60
- Issue
- 2
- Pages
- 534-543
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2070976592
- Cited by
- 67
- References
- 7
- FWCI
- 2.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: P300-Based Brain-Neuronal Computer Interaction for Spelling Applications. https://app.cochat.ai/papers/10.1109/tbme.2012.2228645
- The paper
- Postelnicu, C.-C., & Talaba, D. (2013). P300-Based Brain-Neuronal Computer Interaction for Spelling Applications. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2012.2228645
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.