Unobtrusive, Continuous, In-Home Gait Measurement Using the Microsoft Kinect
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A system for capturing habitual, in-home gait measurements using an environmentally mounted depth camera, the Microsoft Kinect, is presented. Previous work evaluating the use of the Kinect sensor for in-home gait measurement in a lab setting has shown the potential of this approach. In this paper, a single Kinect sensor and computer were deployed in the apartments of older adults in an independent living facility for the purpose of continuous, in-home gait measurement. In addition, a monthly fall risk assessment protocol was conducted for each resident by a clinician, which included traditional tools such as the timed up a go and habitual gait speed tests. A probabilistic methodology for generating automated gait estimates over time for the residents of the apartments from the Kinect data is described, along with results from the apartments as compared to two of the traditionally measured fall risk assessment tools. Potential applications and future work are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Timed “Up & Go”: A Test of Basic Functional Mobility for Frail Elderly Persons
Podsiadlo, D., & Richardson, S. (1991) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1991.tb01616.x · Cited by 14,418
Guralnik, J. M., Simonsick, E. M., Ferrucci, L., Glynn, R. J., Berkman, L. F., Blazer, D. G., Scherr, P. A., & Wallace, R. B. (1994) · Journal of Gerontology · doi:10.1093/geronj/49.2.m85 · Cited by 9,792
Gait velocity as a single predictor of adverse events in healthy seniors aged 75 years and older
Montero-Odasso, M., Schapira, M., Soriano, E. R., Varela, M., Kaplan, R., Camera, L. A., & Mayorga, L. M. (2005) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/60.10.1304 · Cited by 746
Cited by
Human fall detection on embedded platform using depth maps and wireless accelerometer
Kwolek, B., & Kepski, M. (2014) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2014.09.005 · Cited by 650
“As noted in [29], the in-home depth measurements on a person being in sunlight, i.”
BackgroundFall Detection in Homes of Older Adults Using the Microsoft Kinect
Stone, E. E., & Skubic, M. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2312180 · Cited by 528
Self-citationFrom Fall Detection to Fall Prevention: A Generic Classification of Fall-Related Systems
Chaccour, K., Darazi, R., El Hassani, A. H., & Andres, E. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2628099 · Cited by 207
Lebowitz, E. R., Shic, F., Campbell, D., MacLeod, J., & Silverman, W. K. (2015) · Depression and Anxiety · doi:10.1002/da.22333 · Cited by 33
Metadata
- Authors
- Stone, E. E., & Skubic, M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2013-10
- Volume
- 60
- Issue
- 10
- Pages
- 2925-2932
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W1968630667
- Cited by
- 203
- References
- 3
- FWCI
- 56.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.