A Likelihood and Local Constraint Level Set Model for Liver Tumor Segmentation from CT Volumes
The DOI matches its Crossref record; 37 of the 38 references it cites were found in a registry or an index.
Abstract
In computed tomography of liver tumors there is often heterogeneous density, weak boundaries, and the liver tumors are surrounded by other abdominal structures with similar densities. These pose limitations to accurate the hepatic tumor segmentation. We propose a level set model incorporating likelihood energy with the edge energy. The minimization of the likelihood energy approximates the density distribution of the target and the multimodal density distribution of the background that can have multiple regions. In the edge energy formulation, our edge detector preserves the ramp associated with the edges for weak boundaries. We compared our approach to the Chan-Vese and the geodesic level set models and the manual segmentation performed by clinical experts. The Chan-Vese model was not successful in segmenting hepatic tumors and our model outperformed the geodesic level set model. Our results on 18 clinical datasets showed that our algorithm had a Jaccard distance error of 14.4 ± 5.3%, relative volume difference of -8.1 ± 2.1%, average surface distance of 2.4 ± 0.8 mm, RMS surface distance of 2.9 ± 0.7 mm, and the maximum surface distance of 7.2 ± 3.1 mm.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Our proposed method competes with state-of-the-art.”
From Automatic Liver and Lesion Segmentation in CT Using Cascaded Fully Convolutional Neural Networks and 3D Conditional Random Fields (2016) · cites this paper as [15]
In the citing paper
“Furthermore, and in contrast to prior work such as [5,15,16], our proposed method could be generalized to segment multiple organs in medical data using multiple cascaded FCNs.”
From Automatic Liver and Lesion Segmentation in CT Using Cascaded Fully Convolutional Neural Networks and 3D Conditional Random Fields (2016) · cites this paper as [15]
Citations
Cites
Global Cancer Statistics, 2002
Parkin, D. M., Bray, F., Ferlay, J., & Pisani, P. (2005) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.55.2.74 · Cited by 18,196
Fronts propagating with curvature-dependent speed: Algorithms based on Hamilton-Jacobi formulations
Osher, S., & Sethian, J. A. (1988) · Journal of Computational Physics · doi:10.1016/0021-9991(88)90002-2 · Cited by 14,062
Chan, T. F., & Vese, L. A. (2001) · IEEE Transactions on Image Processing · doi:10.1109/83.902291 · Cited by 10,304
Caselles, V., Kimmel, R., & Sapiro, G. (1997) · International Journal of Computer Vision · doi:10.1023/a:1007979827043 · Cited by 5,244
An experimental comparison of min-cut/max- flow algorithms for energy minimization in vision
Boykov, Y., & Kolmogorov, V. (2004) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2004.60 · Cited by 4,577
Snakes, shapes, and gradient vector flow
Xu, C., & Prince, J. L. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.661186 · Cited by 4,001 · cited 2×
“A gradient vector flow (GVF) active contour technique [12] was used to perform hepatic segmentation; then the liver tumor was delineated by a statistical classification algorithm [13].”
The expectation-maximization algorithm
Moon, T. K. (1996) · IEEE Signal Processing Magazine · doi:10.1109/79.543975 · Cited by 3,181
Shape modeling with front propagation: a level set approach
Malladi, R., Sethian, J. A., & Vemuri, B. C. (1995) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.368173 · Cited by 3,158
Adams, R., & Bischof, L. (1994) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.295913 · Cited by 3,138
A Multiphase Level Set Framework for Image Segmentation Using the Mumford and Shah Model
Vese, L. A., & Chan, T. F. (2002) · International Journal of Computer Vision · doi:10.1023/a:1020874308076 · Cited by 2,384
Research works printed but not linked: 2
- wong, 2008, A semi-automated method for liver tumor segmentationbased on 2D region growing with knowledge-based constraints, Proc MICCAI Workshop on 3-D Segmentation in the Clinic A Grand Challenge
- deng, 2008, Editorial: 3D segmentation in the clinic: A grand challenge II?Liver tumor segmentation, Proc Int Conf Med Image Comput Comput -Assisted Intervention
Cited by
H-DenseUNet: Hybrid Densely Connected UNet for Liver and Tumor Segmentation From CT Volumes
Li, X., Chen, H., Qi, X., Dou, Q., Fu, C.-W., & Heng, P.-A. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2845918 · Cited by 2,473
Medical image segmentation using deep learning: A survey
Wang, R., Lei, T., Cui, R., Zhang, B., Meng, H., & Nandi, A. K. (2022) · IET Image Processing · doi:10.1049/ipr2.12419 · Cited by 892
Christ, P. F., Elshaer, M. E. A., Ettlinger, F., Tatavarty, S., Bickel, M., Bilic, P., Rempfler, M., Armbruster, M., Hofmann, F., D’Anastasi, M., et al. (2016) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-46723-8_48 · Cited by 625
3D deeply supervised network for automated segmentation of volumetric medical images
Dou, Q., Yu, L., Chen, H., Jin, Y., Yang, X., Qin, J., & Heng, P.-A. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.05.001 · Cited by 613
RA-UNet: A Hybrid Deep Attention-Aware Network to Extract Liver and Tumor in CT Scans
Jin, Q., Meng, Z., Sun, C., Cui, H., & Su, R. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.605132 · Cited by 468
“DIRCADB DATASET 3DIRCADb Liver 3DIRCADb Tumor Dimension DC Jaccard VOE RVD ASSD MSD DC Chirst et al. [3] 2D 0.943 - 0.107 -0.014 1.6 24 0.56 U-Net as in [34] 2D 0.729 - 0.39 0.87 19.4 119 - Li et al. [45] 2D 0.945 - 0.068 -0.112 1.6 28.2 - Maya et al. [46] 3D - - 0.0554 0.0093 0.78 15.6 - Lu et al. [25] 3D - - 0.0936…”
Influential
Metadata
- Authors
- Li, C., Wang, X., Eberl, S., Fulham, M., Yin, Y., Chen, J., & Feng, D. D.
- Affiliations
- The University of Sydney (AU)
- Shandong Tumor Hospital (CN)
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2013-10
- Volume
- 60
- Issue
- 10
- Pages
- 2967-2977
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2003258143
- Cited by
- 139
- References
- 38
- Citations by year
- 2026: 3 · 2025: 9 · 2024: 14 · 2023: 13 · 2022: 14 · 2021: 18 · 2020: 13 · 2019: 16 · 2018: 15 · 2017: 12 · 2016: 2 · 2015: 4 · 2014: 5 · 2013: 1
- FWCI
- 4.49
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Brain Tumor Detection and Classification
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
- Keywords
- liver tumor segmentation, level set method, edge energy, weak boundaries, CT images, Chan-Vese model, geodesic active contours
- MeSH terms
- Computer Simulation, Carcinoma, Hepatocellular, Humans, Liver Neoplasms, Models, Biological, Pattern Recognition, Automated, Radiographic Image Interpretation, Computer-Assisted, Sensitivity and Specificity, Tomography, X-Ray Computed, Reproducibility of Results, Models, Statistical, Likelihood Functions, Tumor Burden
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.