CoChat

Attenuation of Systolic Blood Pressure and Pulse Transit Time Hysteresis During Exercise and Recovery in Cardiovascular Patients

Open access
Qing Liu, Yan, Bryan P., Cheuk-Man Yu, Yuan-Ting Zhang, Poon, Carmen C. Y. · 2014 · IEEE Transactions on Biomedical Engineering
Cited by 109

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Pulse transit time (PTT) is a cardiovascular parameter of emerging interest due to its potential to estimate blood pressure (BP) continuously and without a cuff. Both linear and nonlinear equations have been used in the estimation of BP based on PTT. This study, however, demonstrates that there is a hysteresis phenomenon between BP and PTT during and after dynamic exercise. A total of 46 subjects including 16 healthy subjects, 13 subjects with one or more cardiovascular risk factors, and 17 patients with cardiovascular disease underwent graded exercise stress test. PTT was measured from electrocardiogram and photoplethysmogram of the left index finger of the subject, i.e., a pathway that includes predominately aorta, brachial, and radial arteries. The results of this study showed that, for the same systolic BP (SBP), PTT measured during exercise was significantly larger than PTT measured during recovery for all subject groups. This hysteresis was further quantified as both normalized area bounded by the SBP-PTT relationship (AreaN) and SBP difference at PTT during peak exercise plus 20 ms (ΔSBP20). Significant attenuation of both AreaN (p <; 0.05) and ΔSBP20 (p <; 0.01) is observed in cardiovascular patients compared with healthy subjects, independent of resting BP. Since the SBP-PTT relationship are determined by the mechanical properties of arterial wall, which is predominately mediated by the sympathetic nervous system through altered vascular smooth muscle (VSM) tone during exercise, results of this study are consistent with the previous findings of autonomic nervous dysfunction in cardiovascular patients. We further conclude that VSM tone has a nonnegligible influence on the BP-PTT relationship and thus should be considered in the PTT-based BP estimation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2013.2286998

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 109

Metadata

Authors
Liu, Q., Yan, B. P., Yu, C.-M., Zhang, Y.-T., & Poon, C. C. Y.
Venue
IEEE Transactions on Biomedical Engineering
Published
2014-02
Volume
61
Issue
2
Pages
346-352
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W1967852667
Cited by
109
References
4
FWCI
4.45
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Attenuation of Systolic Blood Pressure and Pulse Transit Time Hysteresis During Exercise and Recovery in Cardiovascular Patients. https://app.cochat.ai/papers/10.1109/tbme.2013.2286998
The paper
Liu, Q., Yan, B. P., Yu, C.-M., Zhang, Y.-T., & Poon, C. C. Y. (2014). Attenuation of Systolic Blood Pressure and Pulse Transit Time Hysteresis During Exercise and Recovery in Cardiovascular Patients. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2013.2286998

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.