The arterial pulse-wave transit time can be measured between the ECG R-wave and the finger pulse ( rPTT), and has been shown previously to have a linear correlation with blood pressure (BP). We hypothesized that the relationship between rPTT, preejection period (PEP; the R-wave/mechanical cardiac delay), and BP would vary with different vasoactive drugs. Twelve healthy men (mean age 22 yr) were studied. Beat-to-beat measurements were made of rPTT (using ECG and photoplethysmograph finger probe), intra-arterial radial pressure, PEP (using cardiac bioimpedance), and transit time minus PEP ( pPTT). Four drugs (glyceryl trinitrate, angiotensin II, norepinephrine, salbutamol) were administered intravenously over 15 min, with stepped dosage increase every 5 min and a 25-min saline washout between agents. All subjects in all conditions had a negative linear correlation ( R 2 = 0.39) between rPTT and systolic BP (SBP), generally constant between different drugs, apart from four subjects who had a positive rPTT/SBP correlation with salbutamol. The 95% limits of agreement between measured and rPTT-predicted SBP were ±17.0 mmHg. Beat-to-beat variability of rPTT showed better coherence with SBP variability than it did with heart rate variability ( P < 0.001). PEP accounted for a substantial and variable proportion of rPTT (12–35%). Diastolic (DBP) and mean arterial BP (MAP) correlated poorly with rPTT ( R 2 = 0.02 and 0.08, respectively) but better with pPTT ( rPTT corrected for PEP, R 2 = 0.41 and 0.45, respectively). The 95% limits of agreement between measured and pPTT-predicted DBP were ± 17.3 mmHg. In conclusion, the negative correlation between rPTT and SBP is generally constant, even with marked hemodynamic perturbations. However, the relationship is not reliable enough for rPTT to be used as a surrogate marker of SBP, although it may be useful in assessing BP variability. DBP and MAP cannot be predicted from rPTT without correction for PEP. The significant contribution of PEP to rPTT means that rPTT should not be used as a marker of purely vascular function.

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.00657.2005

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The results for HR and SpO2 are within FDA regulatory guidelines, which require errors less than ±10% or ±5 bpm for HR and less than 3.5% for Arms for reflectance mode SpO2.

    “The results for HR and SpO2 are within the regulatory guidelines set by the US Food and Drug Administration (FDA), which require errors less than ± 10 % or ± 5 bpm for HR and less than 3.5 % for Arms for reflectance mode SpO226,27.”

Cites

Flagged first, then by citations

1 of the 41 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Payne, R. A., Symeonides, C. N., Webb, D. J., & Maxwell, S. R. J.
Affiliations
  • Western General Hospital (GB)
  • University of Edinburgh (GB)
Venue
Journal of Applied Physiology
Published
2006-01
Volume
100
Issue
1
Pages
136-141
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2059208589
Cited by
418
References
41
Citations by year
2026: 12 · 2025: 17 · 2024: 15 · 2023: 18 · 2022: 16 · 2021: 25 · 2020: 39 · 2019: 32 · 2018: 40 · 2017: 28 · 2016: 31 · 2015: 18 · 2014: 19 · 2013: 13 · 2012: 16
FWCI
8.20
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Applied Physiology (publishedVersion)
  • PubMed (publishedVersion)
  • Explore Bristol Research (submittedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
Keywords
pulse transit time, beat-to-beat blood pressure, pre-ejection period, systolic blood pressure, diastolic blood pressure, mean arterial pressure, vasoactive drugs, nitroglycerin, angiotensin II, norepinephrine, salbutamol, photoplethysmography, blood pressure variability, heart rate variability
MeSH terms
Adolescent, Adult, Blood Pressure, Blood Pressure Determination, Diagnosis, Computer-Assisted, Electrocardiography, Heart Rate, Humans, Male, Manometry, Pulsatile Flow, Sensitivity and Specificity, Reproducibility of Results, Photoplethysmography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review