The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
A Dynamically Optimized SSVEP Brain–Computer Interface (BCI) Speller
Abstract
The aim of this study was to design a dynamically optimized steady-state visually evoked potential (SSVEP) brain-computer interface (BCI) system with enhanced performance relative to previous SSVEP BCIs in terms of the number of items selectable on the interface, accuracy, and speed. In this approach, the row/column (RC) paradigm was employed in a SSVEP speller to increase the number of items. The target is detected by subsequently determining the row and column coordinates. To improve spelling accuracy, we added a posterior processing after the canonical correlation analysis (CCA) approach to reduce the interfrequency variation between different subjects and named the new signal processing method CCA-RV, and designed a real-time biofeedback mechanism to increase attention on the visual stimuli. To achieve reasonable online spelling speed, both fixed and dynamic approaches for setting the optimal stimulus duration were implemented and compared. Experimental results for 11 subjects suggest that the CCA-RV method and the real-time biofeedback effectively increased accuracy compared with CCA and the absence of real-time feedback, respectively. In addition, both optimization approaches for setting stimulus duration achieved reasonable online spelling performance. However, the dynamic optimization approach yielded a higher practical information transfer rate (PITR) than the fixed optimization approach. The average online PITR achieved by the proposed adaptive SSVEP speller, including the time required for breaks between selections and error correction, was 41.08 bit/min. These results indicate that our BCI speller is promising for use in SSVEP-based BCI applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
BCI2000: A General-Purpose Brain-Computer Interface (BCI) System
Schalk, G., McFarland, D. J., Hinterberger, T., Birbaumer, N., & Wolpaw, J. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827072 · Cited by 3,024
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
The mental prosthesis: assessing the speed of a P300-based brain-computer interface
Donchin, E., Spencer, K. M., & Wijesinghe, R. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847808 · Cited by 1,222
Steady-state visually evoked potentials: Focus on essential paradigms and future perspectives
Vialatte, F.-B., Maurice, M., Dauwels, J., & Cichocki, A. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2009.11.005 · Cited by 1,066
Frequency recognition based on canonical correlation analysis for SSVEP-based BCIs
Lin, Z., Zhang, C., Wu, W., & Gao, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889197 · Cited by 867
Design and implementation of a brain-computer interface with high transfer rates
Cheng, M., Gao, X., Gao, S., & Xu, D. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.803536 · Cited by 818
Bin, G., Gao, X., Yan, Z., Hong, B., & Gao, S. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046002 · Cited by 773
Toward enhanced p300 speller performance
Krusienski, D. J., Sellers, E. W., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.07.017 · Cited by 749
A BCI-based environmental controller for the motion-disabled
Gao, X., Xu, D., Cheng, M., & Gao, S. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814449 · Cited by 637
Pfurtscheller, G. (2010) · Frontiers in Neuroscience · doi:10.3389/fnpro.2010.00003 · Cited by 625
A practical VEP-based brain-computer interface
Wang, Y., Wang, R., Gao, X., Hong, B., & Gao, S. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875576 · Cited by 617
Townsend, G., LaPallo, B. K., Boulay, C. B., Krusienski, D. J., Frye, G. E., Hauser, C. K., Schwartz, N. E., Vaughan, T. M., Wolpaw, J. R., & Sellers, E. W. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.030 · Cited by 570
Multiple Channel Detection of Steady-State Visual Evoked Potentials for Brain-Computer Interfaces
Friman, O., Volosyak, I., & Graser, A. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889160 · Cited by 541
Müller, K.-R., Tangermann, M., Dornhege, G., Krauledat, M., Curio, G., & Blankertz, B. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.09.022 · Cited by 474
A Hybrid BCI System Combining P300 and SSVEP and Its Application to Wheelchair Control
Li, Y., Pan, J., Wang, F., & Yu, Z. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2270283 · Cited by 421
Principles of multivariate analysis: a user's perspective
(1989) · Choice Reviews Online · doi:10.5860/choice.26-5111 · Cited by 417
Human Cerebral Activation during Steady-State Visual-Evoked Responses
Pastor, M. A., Artieda, J., Arbizu, J., Valencia, M., & Masdeu, J. C. (2003) · The Journal of Neuroscience · doi:10.1523/jneurosci.23-37-11621.2003 · Cited by 324
Toward a hybrid brain–computer interface based on imagined movement and visual attention
Allison, B. Z., Brunner, C., Kaiser, V, Müller-Putz, G. R., Neuper, C., & Pfurtscheller, G. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026007 · Cited by 291
L1-Regularized Multiway Canonical Correlation Analysis for SSVEP-Based BCI
Zhang, Y., Zhou, G., Jin, J., Wang, M., Wang, X., & Cichocki, A. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2279680 · Cited by 267
Kelly, S. P., Lalor, E. C., Reilly, R. B., & Foxe, J. J. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847369 · Cited by 233
SSVEP-based Bremen–BCI interface—boosting information transfer rates
Volosyak, I. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036020 · Cited by 232
A novel hybrid BCI speller based on the incorporation of SSVEP into the P300 paradigm
Yin, E., Zhou, Z., Jiang, J., Chen, F., Liu, Y., & Hu, D. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026012 · Cited by 225
Self-citationFrequency and Phase Mixed Coding in SSVEP-Based Brain--Computer Interface
Jia, C., Gao, X., Hong, B., & Gao, S. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2068571 · Cited by 197
Mak, J. N., Arbel, Y., Minett, J. W., McCane, L. M., Yuksel, B., Ryan, D., Thompson, D., Bianchi, L., & Erdogmus, D. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025003 · Cited by 195
Visual Spatial Attention Control in an Independent Brain-Computer Interface
Kelly, S. P., Lalor, E. C., Finucane, C., McDarby, G., & Reilly, R. B. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851510 · Cited by 176
Spelling with non-invasive Brain–Computer Interfaces – Current and future trends
Cecotti, H. (2011) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2011.08.003 · Cited by 172
A Speedy Hybrid BCI Spelling Approach Combining P300 and SSVEP
Yin, E., Zhou, Z., Jiang, J., Chen, F., Liu, Y., & Hu, D. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2281976 · Cited by 167
Self-citationYuan, P., Gao, X., Allison, B., Wang, Y., Bin, G., & Gao, S. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026014 · Cited by 160
Multiple Frequencies Sequential Coding for SSVEP-Based Brain-Computer Interface
Zhang, Y., Xu, P., Liu, T., Hu, J., Zhang, R., & Yao, D. (2012) · PLoS ONE · doi:10.1371/journal.pone.0029519 · Cited by 148
Pan, J., Gao, X., duan, F. Y., Zheng, Y. L., & Gao, S. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036027 · Cited by 142
Target Selection With Hybrid Feature for BCI-Based 2-D Cursor Control
Long, J., Li, Y., Yu, T., & Gu, Z. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2167718 · Cited by 128
On the Quantification of SSVEP Frequency Responses in Human EEG in Realistic BCI Conditions
Kuś, R., Duszyk-Bogorodzka, A., Milanowski, P., Łabęcki, M., Bierzyńska, M., Radzikowska, Z., Michalska, M., Żygierewicz, J., Suffczyński, P., & Durka, P. J. (2013) · PLoS ONE · doi:10.1371/journal.pone.0077536 · Cited by 118
Seno, B. D., Matteucci, M., & Mainardi, L. T. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2032642 · Cited by 116
Pires, G., Nunes, U., & Castelo-Branco, M. S. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2011.10.040 · Cited by 106
Online detection of error-related potentials boosts the performance of mental typewriters
Schmidt, N. M., Blankertz, B., & Treder, M. S. (2012) · BMC Neuroscience · doi:10.1186/1471-2202-13-19 · Cited by 96
Hwang, H.-J., Kim, D. H., Han, C. H., & Im, C. (2013) · Brain Research · doi:10.1016/j.brainres.2013.03.050 · Cited by 95
Gaze independent brain–computer speller with covert visual search tasks
Liu, Y., Zhou, Z., & Hu, D. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.10.049 · Cited by 89
Self-citationSSVEP-Based Brain–Computer Interfaces Using FSK-Modulated Visual Stimuli
Kimura, Y., Tanaka, T., Higashi, H., & Morikawa, N. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2265260 · Cited by 77
Brain–computer interface based on intermodulation frequency
Chen, X., Chen, Z., Gao, S., & Gao, X. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066009 · Cited by 62
Assisted closed-loop optimization of SSVEP-BCI efficiency
Fernández-Vargas, J., Pfaff, H. U., Rodríguez, F. B., & Varona, P. (2013) · Frontiers in Neural Circuits · doi:10.3389/fncir.2013.00027 · Cited by 53
Adaptive SSVEP-Based BCI System With Frequency and Pulse Duty-Cycle Stimuli Tuning Design
Shyu, K., Chiu, Y.-J., Lee, P., Liang, J., & Peng, S.-H. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2265308 · Cited by 27
Zeyl, T. J., & Chau, T. T. (2013) · Pattern Recognition Letters · doi:10.1016/j.patrec.2013.05.020 · Cited by 18
Cited by
Brain–Computer Interface Spellers: A Review
Rezeika, A., Benda, M., Stawicki, P., Gembler, F., Saboor, A., & Volosyak, I. (2018) · Brain Sciences · doi:10.3390/brainsci8040057 · Cited by 391
Stocco, A., Prat, C. S., Losey, D. M., Cronin, J. A., Wu, J., Abernethy, J. A., & Rao, R. P. N. (2015) · PLOS ONE · doi:10.1371/journal.pone.0137303 · Cited by 57
“A larger difference between the frequencies would not have necessarily improved accuracy as many previous experiments have demonstrated effective SSVEP-based BCIs with frequency differences less than or equal to 1 Hz [14,15], with some using frequency differences as small as 0.”
Metadata
- Authors
- Yin, E., Zhou, Z., Jiang, J., Yu, Y., & Hu, D.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2015-06
- Volume
- 62
- Issue
- 6
- Pages
- 1447-1456
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2004959199
- Cited by
- 254
- References
- 44
- FWCI
- 7.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.