The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Inertial Sensor-Based Stride Parameter Calculation From Gait Sequences in Geriatric Patients
Open accessAbstract
A detailed and quantitative gait analysis can provide evidence of various gait impairments in elderly people. To provide an objective decision-making basis for gait analysis, simple applicable tests analyzing a high number of strides are required. A mobile gait analysis system, which is mounted on shoes, can fulfill these requirements. This paper presents a method for computing clinically relevant temporal and spatial gait parameters. Therefore, an accelerometer and a gyroscope were positioned laterally below each ankle joint. Temporal gait events were detected by searching for characteristic features in the signals. To calculate stride length, the gravity compensated accelerometer signal was double integrated, and sensor drift was modeled using a piece-wise defined linear function. The presented method was validated using GAITRite-based gait parameters from 101 patients (average age 82.1 years). Subjects performed a normal walking test with and without a wheeled walker. The parameters stride length and stride time showed a correlation of 0.93 and 0.95 between both systems. The absolute error of stride length was 6.26 cm on normal walking test. The developed system as well as the GAITRite showed an increased stride length, when using a four-wheeled walker as walking aid. However, the walking aid interfered with the automated analysis of the GAITRite system, but not with the inertial sensor-based approach. In summary, an algorithm for the calculation of clinically relevant gait parameters derived from inertial sensors is applicable in the diagnostic workup and also during long-term monitoring approaches in the elderly population.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Gait variability and fall risk in community-living older adults: A 1-year prospective study
Hausdorff, J. M., Rios, D. A., & Edelberg, H. K. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.24893 · Cited by 2,313
Estimation of IMU and MARG orientation using a gradient descent algorithm
Madgwick, S. O. H., Harrison, A. J. L., & Vaidyanathan, R. (2011) · 2011 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975346 · Cited by 2,068
Gait Changes in Older Adults: Predictors of Falls or Indicators of Fear?
Maki, B. E. (1997) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.1997.tb00946.x · Cited by 1,721
Quantitative Gait Markers and Incident Fall Risk in Older Adults
Verghese, J., Holtzer, R., Lipton, R. B., & Wang, C. (2009) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/glp033 · Cited by 948
Gait Analysis: An Introduction
Whittle, M. W. (1986) · Cited by 920
Hausdorff, J. M. (2007) · Human Movement Science · doi:10.1016/j.humov.2007.05.003 · Cited by 868
Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
Aminian, K., Najafi, B., Büla, C., Leyvraz, P.-F., & Robert, P. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00008-8 · Cited by 814
Gait Analysis Using a Shoe-Integrated Wireless Sensor System
Bamberg, S., Benbasat, A. Y., Scarborough, D. M., Krebs, D. E., & Paradiso, J. A. (2008) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2007.899493 · Cited by 737
Zero-Velocity Detection—An Algorithm Evaluation
Skog, I., Handel, P., Nilsson, J. O., & Rantakokko, J. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2060723 · Cited by 662
Cited by
Technology in Parkinson’s disease: challenges and opportunities
Espay, A. J., Bonato, P., Nahab, F. B., Maetzler, W., Dean, J. M., Klucken, J., Eskofier, B. M., Merola, A., Horak, F., Lang, A. E., et al. (2016) · Movement Disorders · doi:10.1002/mds.26642 · Cited by 654
Self-citationToward Pervasive Gait Analysis With Wearable Sensors: A Systematic Review
Chen, S., Lach, J., Lo, B., & Yang, G.-Z. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2608720 · Cited by 443
Pasluosta, C. F., Gassner, H., Winkler, J., Klucken, J., & Eskofier, B. M. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2461555 · Cited by 323
Self-citationDeep Learning for Monitoring of Human Gait: A Review
Alharthi, A. S., Yunas, S. U., & Ozanyan, K. B. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2928777 · Cited by 175
A clinical view on the development of technology‐based tools in managing Parkinson's disease
Maetzler, W., Klucken, J., & Horne, M. (2016) · Movement Disorders · doi:10.1002/mds.26673 · Cited by 162
Self-citationOptimization of IMU sensor placement for the measurement of lower limb joint kinematics
Niswander, W., Wang, W., & Kontson, K. (2020) · Sensors · doi:10.3390/s20215993 · Cited by 116
“Heel 5 Kwakkel 2007 [17], Anwary 2018 [11], Khan 2017 [32], Lau 2008 [33], Rebula 2013 [34] Lateral, below lateral malleolus 3 Anwary 2018 [11], Rampp 2014 [35], Reinfelder 2015 [4]”
IMU-Based Monitoring for Assistive Diagnosis and Management of IoHT: A Review
Bo, F., Yerebakan, M., Dai, Y., Wang, W., Li, J., Hu, B., & Gao, S. (2022) · Healthcare · doi:10.3390/healthcare10071210 · Cited by 35
Metadata
- Authors
- Rampp, A., Barth, J., Schuelein, S., Gassmann, K.-G., Klucken, J., & Eskofier, B. M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2015-04
- Volume
- 62
- Issue
- 4
- Pages
- 1089-1097
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2013337604
- Cited by
- 303
- References
- 34
- FWCI
- 49.10
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.