Micro-CT and Histological Evaluation of an Neural Interface Implanted Within a Blood Vessel
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Recently, we reported the development of a stent-mounted electrode array (Stentrode) capable of chronically recording neural signals from within a blood vessel with high fidelity. Preliminary data suggested incorporation of the Stentrode into the blood vessel wall was associated with improved recording sensitivity. We now investigate neointimal incorporation of the Stentrode, implanted in a cohort of sheep for up to 190 days. METHODS: Micro-CT, obtained from the Imaging and Medical Beamline at the Australian Synchrotron, and histomorphometic techniques developed specifically for evaluation of cerebral vasculature implanted with a stent-electrode array were compared as measures to assess device incorporation and vessel patency. RESULTS: Both micro-CT analysis and histomorphometry, revealed a strong correlation between implant duration and the number of incorporated stent struts. <10% (26/268) of stent struts were covered in neointima in sheep implanted for <2 weeks, increasing to >78% (191/243) between 2 and 4 weeks. Average strut-to-lumen thickness from animals implanted >12 weeks was comparable across both modalities, 339 ±15 μm measured using micro-CT and 331 ±19 μm ( n = 292) measured histologically. There was a strong correlation between lumen areas measured using the two modalities ( ), with no observation of vessel occlusion observed from any of the 12 animals implanted for up to 190 days. CONCLUSION: Micro-CT and the histomorphometric techniques we developed are comparable and can both be used to identify incorporation of a Stentrode implanted in cerebral vessels. SIGNIFICANCE: This study demonstrates preliminary safety of a stent-electrode array implanted in cerebral vasculature, which may facilitate technological advances in minimally invasive brain-computer interfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719 · cited 1×
“ECENT years have seen an increase in the use of neural implants for chronic recording and stimulation in the diagnosis, rehabilitation and treatment of patients with epilepsy, paralysis and a range of neuropsychiatric disorders [1-3].”
BackgroundMetscher, B. D. (2009) · BMC Physiology · doi:10.1186/1472-6793-9-11 · Cited by 1,086 · cited 1×
“Prior to evaluation and imaging of tissue using the Australian Synchrotron, tissues were immersed in Lugol’s solution (5% wt/v iodine, 10% wt/v potassium iodine; Complementary Components, Australia) for 96 hours [26].”
MethodBrain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622 · cited 1×
“Breach of the blood brain barrier induces gliosis and immunological responses which can cause electrode decomposition and failure [4-9].”
BackgroundMcConnell, G. C., Rees, H. D., Levey, A. I., Gutekunst, C.-A., Gross, R. E., & Bellamkonda, R. V. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/5/056003 · Cited by 480 · cited 1×
“Breach of the blood brain barrier induces gliosis and immunological responses which can cause electrode decomposition and failure [4-9].”
BackgroundPrasad, A., Xue, Q.-S., Sankar, V., Nishida, T., Shaw, G., Streit, W. J., & Sanchez, J. C. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/5/056015 · Cited by 298 · cited 1×
“Breach of the blood brain barrier induces gliosis and immunological responses which can cause electrode decomposition and failure [4-9].”
Background
Cited by
Oxley, T. J., Yoo, P. E., Rind, G. S., Ronayne, S. M., Lee, C. M. S., Bird, C., Hampshire, V., Sharma, R. P., Morokoff, A., Williams, D. L., et al. (2021) · Journal of NeuroInterventional Surgery · doi:10.1136/neurintsurg-2020-016862 · Cited by 243
Self-citationRecent advances in neural electrode–tissue interfaces
Woeppel, K., Yang, Q., & Cui, X. T. (2017) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.09.003 · Cited by 99
Endovascular neuromodulation: safety profile and future directions
Raza, S. A., Opie, N. L., Morokoff, A., Sharma, R. P., Mitchell, P. J., & Oxley, T. J. (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.00351 · Cited by 29
“Data from phase angle measurements, histological studies and micro-CT imaging of Stentrodes implanted in sheep suggest that within four weeks of implantation, greater than 85% of stent struts become covered in neo-intima, and after 100 days of implantation, nearly all stent struts are covered in endothelium (38, 39).”
MethodSelf-citationRecent advances in recording and modulation technologies for next-generation neural interfaces.
Hong, J.-W., Yoon, C., Jo, K., Won, J. H., & Park, S. (2021) · iScience · doi:10.1016/j.isci.2021.103550 · Cited by 25
Metadata
- Authors
- Opie, N. L., van der Nagel, N. R., John, S. E., Vessey, K., Rind, G. S., Ronayne, S. M., Fletcher, E. L., May, C. N., O'Brien, T. J., & Oxley, T. J.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2017-04
- Volume
- 64
- Issue
- 4
- Pages
- 928-934
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2467793082
- Cited by
- 56
- References
- 5
- FWCI
- 2.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Micro-CT and Histological Evaluation of an Neural Interface Implanted Within a Blood Vessel. https://app.cochat.ai/papers/10.1109/tbme.2016.2552226
- The paper
- Opie, N. L., van der Nagel, N. R., John, S. E., Vessey, K., Rind, G. S., Ronayne, S. M., Fletcher, E. L., May, C. N., O'Brien, T. J., & Oxley, T. J. (2017). Micro-CT and Histological Evaluation of an Neural Interface Implanted Within a Blood Vessel. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2016.2552226
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.