Consistency of Long-Term Subdural Electrocorticography in Humans
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Subdural electrocorticography (ECoG) can provide a robust control signal for a brain-computer interface (BCI). However, the long-term recording properties of ECoG are poorly understood as most ECoG studies in the BCI field have only used signals recorded for less than 28 days. We assessed human ECoG recordings over durations of many months to investigate changes to recording quality that occur with long-term implantation. METHODS: We examined changes in signal properties over time from 15 ambulatory humans who had continuous subdural ECoG monitoring for 184-766 days. RESULTS: Individual electrodes demonstrated varying changes in frequency power characteristics over time within individual patients and between patients. Group level analyses demonstrated that there were only small changes in effective signal bandwidth and spectral band power across months. High-gamma signals could be recorded throughout the study, though there was a decline in signal power for some electrodes. CONCLUSION: ECoG-based BCI systems can robustly record high-frequency activity over multiple years, albeit with marked intersubject variability. SIGNIFICANCE: Group level results demonstrated that ECoG is a promising modality for long-term BCI and neural prosthesis applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721
Power-Law Scaling in the Brain Surface Electric Potential
Miller, K. J., Sorensen, L. B., Ojemann, J. G., & den Nijs, M. (2009) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1000609 · Cited by 742
Electrocorticographic control of a prosthetic arm in paralyzed patients
Yanagisawa, T., Hirata, M., Saitoh, Y., Kishima, H., Matsushita, K., Goto, T., Fukuma, R., Yokoi, H., Kamitani, Y., & Yoshimine, T. (2012) · Annals of Neurology · doi:10.1002/ana.22613 · Cited by 256 · cited 1×
“[13] demonstrated that motor impaired patients can control a prosthetic arm with ECoG.”
Background
Cited by
Signal quality and patient experience with wearable devices for epilepsy management
Nasseri, M., Nurse, E., Glasstetter, M., Böttcher, S., Gregg, N. M., Laks Nandakumar, A., Joseph, B., Pal Attia, T., Viana, P. F., Bruno, E., et al. (2020) · Epilepsia · doi:10.1111/epi.16527 · Cited by 90
Self-citationMoly, A., Costecalde, T., Martel, F., Martin, M., Larzabal, C., Karakas, S., Verney, A., Charvet, G., Chabardes, S., Benabid, A. L., et al. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac59a0 · Cited by 65
Long-term stability of the chronic epidural wireless recorder WIMAGINE in tetraplegic patients
Larzabal, C., Bonnet, S., Costecalde, T., Auboiroux, V., Charvet, G., Chabardes, S., Aksenova, T., & Sauter-Starace, F. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac2003 · Cited by 37
“The stability of the ECoG signal was assessed by using state of the art indicators: RMS voltage, BP [31], SNR, EBW [27] and SEF [33].”
Influential
Metadata
- Authors
- Nurse, E. S., John, S. E., Freestone, D. R., Oxley, T. J., Ung, H., Berkovic, S. F., O'Brien, T. J., Cook, M. J., & Grayden, D. B.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2018-02
- Volume
- 65
- Issue
- 2
- Pages
- 344-352
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2765239283
- Cited by
- 59
- References
- 3
- FWCI
- 3.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.