CoChat

Rehab-Net: Deep Learning Framework for Arm Movement Classification Using Wearable Sensors for Stroke Rehabilitation

Panwar, Madhuri, Biswas, Dwaipayan, Bajaj, Harsh, Jobges, Michael, Turk, Ruth, Maharatna, Koushik, Acharyya, Amit · 2019 · IEEE Transactions on Biomedical Engineering

The DOI matches its Crossref record; 60 of the 62 references it cites were found in a registry or an index.

Abstract

In this paper, we present a deep learning framework “Rehab-Net” for effectively classifying three upper limb movements of the human arm, involving extension, flexion, and rotation of the forearm, which, over the time, could provide a measure of rehabilitation progress. The proposed framework, Rehab-Net is formulated with a personalized, light weight and low-complex, customized convolutional neural network (CNN) model, using two-layers of CNN, interleaved with pooling layers, followed by a fully connected layer that classifies the three movements from tri-axial acceleration input data collected from the wrist. The proposed Rehab-Net framework was validated on sensor data collected in two situations: 1) semi-naturalistic environment involving an archetypal activity of “making-tea” with four stroke survivors and 2) natural environment, where ten stroke survivors were free to perform any desired arm movement for the duration of 120 min. We achieved an overall accuracy of 97.89% on semi-naturalistic data and 88.87% on naturalistic data which exceeded state-of-the-art learning algorithms namely, linear discriminant analysis, support vector machines, and k-means clustering with an average accuracy of 48.89%, 44.14%, and 27.64%. Subsequently, a computational complexity analysis of the proposed model has been discussed with an eye toward hardware implementation. The clinical significance of this study is to accurately monitor the clinical progress of the rehabilitated subjects under t…

Overview

Integrity signals

Registry

Crossref · 10.1109/tbme.2019.2899927

Cites

60 of 60 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 60 references

Cited by

See all 158

Metadata

Authors
Panwar, M., Biswas, D., Bajaj, H., Jobges, M., Turk, R., Maharatna, K., & Acharyya, A.
Affiliations
  • Indian Institute of Technology Hyderabad (IN)
  • IMEC (BE)
  • National Institute of Technology Tiruchirappalli (IN)
  • University of Southampton (GB)
Venue
IEEE Transactions on Biomedical Engineering
Published
2019-11
Volume
66
Issue
11
Pages
3026-3037
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2916879374
Cited by
158
References
62
Citations by year
2026: 9 · 2025: 22 · 2024: 26 · 2023: 24 · 2022: 28 · 2021: 29 · 2020: 18 · 2019: 2
FWCI
8.62
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • ePrints Soton (University of Southampton) (acceptedVersion)
  • Research Archive of Indian Institute of Technology Hyderabad (Indian Institute of Technology Hyderabad) (submittedVersion)
Funders
Science and Engineering Research Board (ECR/2015/000148)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
Keywords
stroke rehabilitation, upper limb movement classification, wearable sensors, triaxial accelerometer, convolutional neural networks, rehabilitation progress monitoring, outpatient rehabilitation, forearm rotation
MeSH terms
Stroke Rehabilitation, Wearable Electronic Devices, Deep Learning, Aged, Algorithms, Arm, Female, Humans, Human Activities, Male, Middle Aged, Movement, Cluster Analysis, Support Vector Machine

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.