Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 212

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Classification of Alzheimer's Disease Using Whole Brain Hierarchical Network

Liu, Jin, Li, Min, Lan, Wei, Wu, Fang-Xiang, Pan, Yi, Wang, Jianxin · 2018 · IEEE/ACM Transactions on Computational Biology and Bioinformatics

Abstract

Regions of interest (ROIs) based classification has been widely investigated for analysis of brain magnetic resonance imaging (MRI) images to assist the diagnosis of Alzheimer's disease (AD) including its early warning and developing stages, e.g., mild cognitive impairment (MCI) including MCI converted to AD (MCIc) and MCI not converted to AD (MCInc). Since an ROI representation of brain structures is obtained either by pre-definition or by adaptive parcellation, the corresponding ROI in different brains can be measured. However, due to noise and small sample size of MRI images, representations generated from single or multiple ROIs may not be sufficient to reveal the underlying anatomical differences between the groups of disease-affected patients and health controls (HC). In this paper, we employ a whole brain hierarchical network (WBHN) to represent each subject. The whole brain of each subject is divided into 90, 54, 14, and 1 regions based on Automated Anatomical Labeling (AAL) atlas. The connectivity between each pair of regions is computed in terms of Pearson's correlation coefficient and used as classification feature. Then, to reduce the dimensionality of features, we select the features with higher scores. Finally, we use multiple kernel boosting (MKBoost) algorithm to perform the classification. Our proposed method is evaluated on MRI images of 710 subjects (200 AD, 120 MCIc, 160 MCInc, and 230 HC) from the Alzheimer's Disease Neuroimaging Initiative (ADNI) database. The experimental results show that our proposed method achieves an accuracy of 94.65 percent and an area under the receiver operating characteristic (ROC) curve (AUC) of 0.954 for AD/HC classification, an accuracy of 89.63 percent and an AUC of 0.907 for AD/MCI classification, an accuracy of 85.79 percent and an AUC of 0.826 for MCI/HC classification, and an accuracy of 72.08 percent and an AUC of 0.716 for MCIc/MCInc classification, respectively. Our results demonstrate that our proposed method is efficient and promising for clinical applications for the diagnosis of AD via MRI images.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tcbb.2016.2635144

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 212

Metadata

Authors
Liu, J., Li, M., Lan, W., Wu, F.-X., Pan, Y., & Wang, J.
Venue
IEEE/ACM Transactions on Computational Biology and Bioinformatics
Published
2018-03-01
Volume
15
Issue
2
Pages
624-632
ISSN
  • 1545-5963 (ISSN-L)
  • 1557-9964
  • 2374-0043
OpenAlex
W2558927549
Cited by
212
References
10
FWCI
10.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.