iGLU 2.0: A New Wearable for Accurate Non-Invasive Continuous Serum Glucose Measurement in IoMT Framework
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
People around the globe rely on their blood samples for their glucose level measurement. There is a demand for non-invasive, precise and cost-effective solutions to monitor blood glucose level and control of diabetes. Serum glucose is an accurate blood glucose measurement method in comparison to capillary glucose measurement. Presently, the serum glucose is measured through laboratory setup with an invasive approach. The invasive method is painful and is not suitable for continuous glucose measurement. In this paper, we propose a novel wearable non-invasive consumer device (called iGLU 2.0) which can be used by consumers for accurate continuous blood glucose monitoring. This device uses a novel short near infrared (NIR) spectroscopy developed by us. It is incorporated with Internet-of-Medical-Things (IoMT) for smart healthcare where the healthcare data is stored on the cloud and is accessible to the users and caregivers. Analysis of the optimized regression model is performed and the system is calibrated and validated through healthy, prediabetic and diabetic patients. The robust regression models of serum glucose level is then deployed as the mechanism for precise measurement in iGLU 2.0. The performance of iGLU 2.0 is validated with the prediction of capillary blood glucose using Average Error (AvgE) and Mean Absolute Relative Difference (mARD) which are calculated as 6.09% and 6.07%, respectively, whereas for serum glucose, AvgE and mARD are estimated as 4.88% and 4.86%, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Everything you wanted to know about smart cities: the Internet of Things is the backbone
Mohanty, S. P., Choppali, U., & Kougianos, E. (2016) · IEEE Consumer Electronics Magazine · doi:10.1109/mce.2016.2556879 · Cited by 1,056
Self-citationMonte-Moreno, E. (2011) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2011.05.001 · Cited by 311
Cited by
Sun, W., Guo, Z., Yang, Z., Wu, Y., Lan, W., Liao, Y., Wu, X., & Liu, Y. (2022) · Sensors · doi:10.3390/s22207784 · Cited by 112
“A pair of reverse iontophoresis electrodes, a reference electrode, and a working electrode were printed on the substrate by a screen-printing process, and the working electrode was modified with lactate oxidase.”
MethodOverview of Artificial Intelligence–Driven Wearable Devices for Diabetes: Scoping Review
Ahmed, A., Aziz, S., Abd-alrazaq, A., Farooq, F., & Sheikh, J. (2022) · Journal of Medical Internet Research · doi:10.2196/36010 · Cited by 57
Zheng, Y., Zhan, Z., Chen, Q., Chen, J., Luo, J., Cai, J., Zhou, Y., Chen, K., & Xie, W. (2024) · Advanced Science · doi:10.1002/advs.202405681 · Cited by 38
Metadata
- Authors
- Joshi, A. M., Jain, P., Mohanty, S. P., & Agrawal, N.
- Venue
- IEEE Transactions on Consumer Electronics
- Published
- 2020-11
- Volume
- 66
- Issue
- 4
- Pages
- 327-335
- ISSN
- 0098-3063 (ISSN-L)
- 1558-4127
- OpenAlex
- W3045507108
- Cited by
- 122
- References
- 2
- FWCI
- 6.88
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.