The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Wideband Frequency-Shift Keying Wireless Link for Inductively Powered Biomedical Implants
Abstract
A high data-rate frequency-shift keying (FSK) modulation protocol, a wideband inductive link, and three demodulator circuits have been developed with a data-rate-to-carrier-frequency ratio of up to 67%. The primary application of this novel FSK modulation/demodulation technique is to send data to inductively powered wireless biomedical implants at data rates in excess of 1 Mbps, using comparable carrier frequencies. This method can also be used in other applications such as radio-frequency identification tags and contactless smartcards by adding a back telemetry link. The inductive link utilizes a series-parallel inductive-capacitance tank combination on the transmitter side to provide more than 5 MHz of bandwidth. The demodulator circuits detect data bits by directly measuring the duration of each received FSK carrier cycle, as well as derive a constant frequency clock, which is used to sample the data bits. One of the demodulator circuits, digital FSK, occupies 0.29 mm/sup 2/ in the AMI 1.5-/spl mu/m, 2M/2P, standard CMOS process, and consumes 0.38 mW at 5 V. This circuit is simulated up to 4 Mbps, and experimentally tested up to 2.5 Mbps with a bit error rate of 10/sup -5/, while receiving a 5/10-MHz FSK carrier signal. It is also used in a wireless implantable neural microstimulation system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Simulation of a phosphene-based visual field: Visual acuity in a pixelized vision system
Cha, K., Horch, K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368135 · Cited by 198
Cited by
Fully integrated wideband high-current rectifiers for inductively powered devices
Ghovanloo, M., & Najafi, K. (2004) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2004.835822 · Cited by 296
Self-citationUltralow-Power Electronics for Biomedical Applications
Chandrakasan, A. P., Verma, N., & Daly, D. C. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160547 · Cited by 285
An Implantable 64-Channel Wireless Microsystem for Single-Unit Neural Recording
Sodagar, A. M., Perlin, G. E., Yao, Y., Najafi, K., & Wise, K. D. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2023159 · Cited by 218
Self-citationLow-Power Circuits for Brain–Machine Interfaces
Sarpeshkar, R., Wattanapanitch, W., Arfin, S. K., Rapoport, B. I., Mandal, S., Baker, M. W., Fee, M. S., Musallam, S., & Andersen, R. A. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.2003198 · Cited by 91
Metadata
- Authors
- Ghovanloo, M., & Najafi, K.
- Venue
- IEEE Transactions on Circuits and Systems I: Regular Papers
- Published
- 2004-12
- Volume
- 51
- Issue
- 12
- Pages
- 2374-2383
- ISSN
- 1057-7122 (ISSN-L)
- OpenAlex
- W2097698664
- Cited by
- 290
- References
- 1
- FWCI
- 13.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Wideband Frequency-Shift Keying Wireless Link for Inductively Powered Biomedical Implants. https://app.cochat.ai/papers/10.1109/tcsi.2004.838144
- The paper
- Ghovanloo, M., & Najafi, K. (2004). A Wideband Frequency-Shift Keying Wireless Link for Inductively Powered Biomedical Implants. IEEE Transactions on Circuits and Systems I: Regular Papers. https://doi.org/10.1109/tcsi.2004.838144
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.