The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Fully integrated wideband high-current rectifiers for inductively powered devices
Abstract
This paper describes the design and implementation of fully integrated rectifiers in BiCMOS and standard CMOS technologies for rectifying an externally generated RF carrier signal in inductively powered wireless devices, such as biomedical implants, radio-frequency identification (RFID) tags, and smartcards to generate an on-chip dc supply. Various full-wave rectifier topologies and low-power circuit design techniques are employed to decrease substrate leakage current and parasitic components, reduce the possibility of latch-up, and improve power transmission efficiency and high-frequency performance of the rectifier block. These circuits are used in wireless neural stimulating microsystems, fabricated in two processes: the University of Michigan's 3-/spl mu/m 1M/2P N-epi BiCMOS, and the AMI 1.5-/spl mu/m 2M/2P N-well standard CMOS. The rectifier areas are 0.12-0.48 mm/sup 2/ in the above processes and they are capable of delivering >25mW from a receiver coil to the implant circuitry. The performance of these integrated rectifiers has been tested and compared, using carrier signals in 0.1-10-MHz range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis and Design of Analog Integrated Circuits
Betts, W. R. (1978) · Electronics and Power · doi:10.1049/ep.1978.0296 · Cited by 3,827
A neuro-stimulus chip with telemetry unit for retinal prosthetic device
Liu, W., Vichienchom, K., Clements, M., DeMarco, S. C., Hughes, C., McGucken, E., Humayun, M. S., De Juan, E., Weiland, J. D., & Greenberg, R. (2000) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.871327 · Cited by 371
A Wideband Frequency-Shift Keying Wireless Link for Inductively Powered Biomedical Implants
Ghovanloo, M., & Najafi, K. (2004) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2004.838144 · Cited by 290
Self-citationRF powering of millimeter- and submillimeter-sized neural prosthetic implants
Heetderks, W. J. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.1388 · Cited by 197
A Wide-Band Efficient Inductive Transdennal Power and Data Link with Coupling Insensitive Gain
Galbraith, D. C., Soma, M., & White, R. L. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326076 · Cited by 192
Suaning, G. J., & Lovell, N. H. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.909646 · Cited by 164
A Modular 32-site wireless neural stimulation microsystem
Ghovanloo, M., & Najafi, K. (2004) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2004.837026 · Cited by 151
Self-citationA programmable intraocular CMOS pressure sensor system implant
Stangel, K., Kolnsberg, S., Hammerschmidt, D., Hosticka, B. J., Trieu, H. K., & Mokwa, W. (2001) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.933466 · Cited by 139
A 64-site multishank CMOS low-profile neural stimulating probe
Kim, C., & Wise, K. D. (1996) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.535406 · Cited by 103
Low-power interface circuits for bio-implantable microsystems
Yu, H., & Najafi, K. (2003) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2003.1234263 · Cited by 82
Self-citation
Cited by
A low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782
A Low-Power Integrated Circuit for a Wireless 100-Electrode Neural Recording System
Harrison, R., Watkins, P., Kier, R., Lovejoy, R., Black, D., Normann, R., & Solzbacher, F. (2006) · 2006 IEEE International Solid State Circuits Conference - Digest of Technical Papers · doi:10.1109/isscc.2006.1696288 · Cited by 731
A Wireless-Implantable Microsystem for Continuous Blood Glucose Monitoring
Ahmadi, M. M., & Jullien, G. A. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2016844 · Cited by 266
Lee, S.-Y., Su, M. Y., Liang, M.-C., Chen, Y.-Y., Hsieh, C.-H., Yang, C.-M., Lai, H.-Y., Lin, J.-W., & Fang, Q. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2177661 · Cited by 102
A Complete 256-Electrode Retinal Prosthesis Chip
Tran, N., Bai, S., Yang, J., Chun, H., Kavehei, O., Yang, Y., Muktamath, V., Ng, D., Meffin, H., Halpern, M., et al. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2298037 · Cited by 90
Metadata
- Authors
- Ghovanloo, M., & Najafi, K.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2004-11
- Volume
- 39
- Issue
- 11
- Pages
- 1976-1984
- ISSN
- 0018-9200 (ISSN-L)
- OpenAlex
- W1982987056
- Cited by
- 296
- References
- 19
- FWCI
- 11.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fully integrated wideband high-current rectifiers for inductively powered devices. https://app.cochat.ai/papers/10.1109/jssc.2004.835822
- The paper
- Ghovanloo, M., & Najafi, K. (2004). Fully integrated wideband high-current rectifiers for inductively powered devices. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2004.835822
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.