The DOI matches its Crossref record.
An optimal design methodology for inductive power link with class-E amplifier
Abstract
This paper presents a design methodology of a highly efficient power link based on Class-E driven, inductively coupled coil pair. An optimal power link design for retinal prosthesis and/or other implants must take into consideration the allowable safety limits of magnetic fields, which in turn govern the inductances of the primary and secondary coils. In retinal prosthesis, the optimal coil inductances have to deal with the constraints of the coil sizes, the tradeoffs between the losses, H-field limitation and dc supply voltage required by the Class-E driver. Our design procedure starts with the formation of equivalent circuits, followed by the analysis of the loss of the rectifier and coils and the H-field for induced voltage and current. Both linear and nonlinear models for the analysis are presented. Based on the procedure, an experimental power link is implemented with an overall efficiency of 67% at the optimal distance of 7 mm between the coils. In addition to the coil design methodology, we are also presenting a closed-loop control of Class-E amplifier for any duty cycle and any value of the systemQ.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Jow, U.-M., & Ghovanloo, M. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.913130 · Cited by 630
Design and Optimization of a 3-Coil Inductive Link for Efficient Wireless Power Transmission
Kiani, M., Jow, U.-M., & Ghovanloo, M. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2158431 · Cited by 591
Wireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
Low, Z. N., Chinga, R. A., Tseng, R., & Lin, J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2010110 · Cited by 528
Design and analysis of an adaptive transcutaneous power telemetry for biomedical implants
Wang, G., Liu, W., Sivaprakasam, M., & Kendir, G. A. (2005) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2005.852923 · Cited by 435
Self-citation
Metadata
- Authors
- Kendir, G. A., Liu, W., Wang, G., Sivaprakasam, M., Bashirullah, R., Humayun, M. S., & Weiland, J. D.
- Venue
- IEEE Transactions on Circuits and Systems I: Regular Papers
- Published
- 2005-05
- Volume
- 52
- Issue
- 5
- Pages
- 857-866
- ISSN
- 1057-7122 (ISSN-L)
- OpenAlex
- W2152121880
- Cited by
- 222
- References
- 0
- FWCI
- 9.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An optimal design methodology for inductive power link with class-E amplifier. https://app.cochat.ai/papers/10.1109/tcsi.2005.846208
- The paper
- Kendir, G. A., Liu, W., Wang, G., Sivaprakasam, M., Bashirullah, R., Humayun, M. S., & Weiland, J. D. (2005). An optimal design methodology for inductive power link with class-E amplifier. IEEE Transactions on Circuits and Systems I: Regular Papers. https://doi.org/10.1109/tcsi.2005.846208
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.