The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Nuclei Segmentation Using Marker-Controlled Watershed, Tracking Using Mean-Shift, and Kalman Filter in Time-Lapse Microscopy
Abstract
It is important to observe and study cancer cells' cycle progression in order to better understand drug effects on cancer cells. Time-lapse microscopy imaging serves as an important method to measure the cycle progression of individual cells in a large population. Since manual analysis is unreasonably time consuming for the large volumes of time-lapse image data, automated image analysis is proposed. Existing approaches dealing with time-lapse image data are rather limited and often give inaccurate analysis results, especially in segmenting and tracking individual cells in a cell population. In this paper, we present a new approach to segment and track cell nuclei in time-lapse fluorescence image sequence. First, we propose a novel marker-controlled watershed based on mathematical morphology, which can effectively segment clustered cells with less oversegmentation. To further segment undersegmented cells or to merge oversegmented cells, context information among neighboring frames is employed, which is proved to be an effective strategy. Then, we design a tracking method based on modified mean shift algorithm, in which several kernels with adaptive scale, shape, and direction are designed. Finally, we combine mean-shift and Kalman filter to achieve a more robust cell nuclei tracking method than existing ones. Experimental results show that our method can obtain 98.8% segmentation accuracy, 97.4% cell division tracking accuracy, and 97.6% cell tracking accuracy
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kass, M., Witkin, A., & Terzopoulos, D. (1988) · International Journal of Computer Vision · doi:10.1007/bf00133570 · Cited by 17,070
Mean shift: a robust approach toward feature space analysis
Comaniciu, D., & Meer, P. (2002) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.1000236 · Cited by 11,305
Watersheds in digital spaces: an efficient algorithm based on immersion simulations
Vincent, L., & Soille, P. (1991) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.87344 · Cited by 5,649
An Introduction to the Kalman Filter
Welch, G., & Bishop, G. (1995) · CiteSeer X (The Pennsylvania State University) · Cited by 4,895
Snakes, shapes, and gradient vector flow
Xu, C., & Prince, J. L. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.661186 · Cited by 4,001
Mean shift, mode seeking, and clustering
Cheng, Y. (1995) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.400568 · Cited by 3,856
Feature detection with automatic scale selection
Lindeberg, T. (1998) · International Journal of Computer Vision · doi:10.1023/a:1008045108935 · Cited by 2,541
Witkin, A. P. (1987) · Readings in Computer Vision · doi:10.1016/b978-0-08-051581-6.50036-2 · Cited by 2,359
Jähne, B. (2002) · Springer eBooks · doi:10.1007/978-3-662-04781-1 · Cited by 1,662
Scale-space filtering: A new approach to multi-scale description
Witkin, A. (2005) · ICASSP '84. IEEE International Conference on Acoustics, Speech, and Signal Processing · doi:10.1109/icassp.1984.1172729 · Cited by 1,086
Cited by
Hover-Net: Simultaneous segmentation and classification of nuclei in multi-tissue histology images
Graham, S., Vu, Q. D., Raza, S. E. A., Azam, A., Tsang, Y. W., Kwak, J. T., & Rajpoot, N. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.101563 · Cited by 1,423
A Multi-Organ Nucleus Segmentation Challenge
Kumar, N., Verma, R., Anand, D., Zhou, Y., Onder, O. F., Tsougenis, E., Chen, H., Heng, P.-A., Li, J., Hu, Z., et al. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2947628 · Cited by 553
Self-citationXing, F., & Yang, L. (2016) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2016.2515127 · Cited by 519
Automatic Nuclei Segmentation in H&E Stained Breast Cancer Histopathology Images
Veta, M., van Diest, P. J., Kornegoor, R., Huisman, A., Viergever, M. A., & Pluim, J. P. W. (2013) · PLoS ONE · doi:10.1371/journal.pone.0070221 · Cited by 369
An Automatic Learning-Based Framework for Robust Nucleus Segmentation
Xing, F., Xie, Y., & Yang, L. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2481436 · Cited by 351
Metadata
- Authors
- Yang, X., Li, H., & Zhou, X.
- Venue
- IEEE Transactions on Circuits and Systems I: Regular Papers
- Published
- 2006-11
- Volume
- 53
- Issue
- 11
- Pages
- 2405-2414
- ISSN
- 1057-7122 (ISSN-L)
- OpenAlex
- W2151538727
- Cited by
- 404
- References
- 20
- FWCI
- 4.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nuclei Segmentation Using Marker-Controlled Watershed, Tracking Using Mean-Shift, and Kalman Filter in Time-Lapse Microscopy. https://app.cochat.ai/papers/10.1109/tcsi.2006.884469
- The paper
- Yang, X., Li, H., & Zhou, X. (2006). Nuclei Segmentation Using Marker-Controlled Watershed, Tracking Using Mean-Shift, and Kalman Filter in Time-Lapse Microscopy. IEEE Transactions on Circuits and Systems I: Regular Papers. https://doi.org/10.1109/tcsi.2006.884469
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.