Cited by 83Wireless Power Transfer SystemsWireless Body Area NetworksInduction Heating and Inverter Technology

The DOI matches its Crossref record; the references it cites are not checked yet.

Wireless Power Transfer System With High Misalignment Tolerance for Bio-Medical Implants

Wang, Qinghua, Che, Wenquan, Mongiardo, Mauro, Monti, Giuseppina·2020·IEEE Transactions on Circuits and Systems II: Express Briefs

Abstract

A hybrid array resonator structure for Wireless Power Transfer (WPT) is presented. The proposed structure exploits an array of four identical coils surrounded by a larger coil to generate uniform magnetic field. As a result, a nearly constant and high efficiency is achieved over a large misalignment region. The quasi-uniform magnetic field distribution of the proposed structure is analytically derived. For demonstration, one prototype operating at 40 MHz is designed for implantable medical devices (IMDs). According to experimental results, the developed WPT system exhibits an efficiency of 53% when the receiver and the transmitter are aligned, while the efficiency is 44% when they operate with a lateral misalignment of 10 mm. As per a conventional WPT system using a single spiral resonator as transmitter and receiver, the efficiency is 47.2% in aligned condition, while, it is 30.5% for a 10 mm lateral misalignment. The reported results demonstrate that the proposed design approach provides a high misalignment tolerance. This represents an attractive future for applications, such as the recharge of embedded devices, where the alignment between the transmitter and the receiver is difficult to guarantee.

Overview

Integrity signals

Registry

Crossref · 10.1109/tcsii.2020.2985056

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

The citation lists haven’t been fetched yet

References 13 · Cited by 83

Research works printed but not linked: 13

  1. 10.1109/TMTT.2015.2481387 · DOI
  2. 10.1109/WPT.2015.7140176 · DOI
  3. 10.1109/TMAG.2012.2235181 · DOI
  4. 10.1109/IEEESTD.2006.99501 · DOI
  5. 10.2528/PIER18102402 · DOI
  6. 10.1109/LAWP.2013.2238993 · DOI
  7. 10.1109/MWSYM.2015.7166947 · DOI
  8. 10.1109/LAWP.2013.2239600 · DOI
  9. 10.1088/0031-9155/41/11/003 · DOI · Paper page
  10. 10.6028/jres.105.045 · DOI
  11. jow, 2009, Modeling and optimization of printed spiral coils in air, saline, and muscle tissue environments, IEEE Trans Biomed Circuits Syst, 3, 339, 10.1109/TBCAS.2009.2025366 · DOI · Paper page
  12. 10.1109/TBCAS.2017.2787649 · DOI
  13. 10.1109/TBCAS.2010.2072782 · DOI

Metadata

Authors
Wang, Q., Che, W., Mongiardo, M., & Monti, G.
Affiliations
  • Nanjing University of Science and Technology (CN)
  • South China University of Technology (CN)
  • University of Perugia (IT)
  • University of Salento (IT)
Venue
IEEE Transactions on Circuits and Systems II: Express Briefs
Published
2020-12
Volume
67
Issue
12
Pages
3023-3027
ISSN
  • 1549-7747 (ISSN-L)
  • 1558-3791
OpenAlex
W3014156965
Cited by
83
References
13
Citations by year
2026: 4 · 2025: 15 · 2024: 16 · 2023: 20 · 2022: 17 · 2021: 9 · 2020: 2
FWCI
4.12
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Circuits & Systems II Express Briefs (publishedVersion)
  • AIRUS (submittedVersion)
Funders
Natural Science Foundation of China (61931009)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Induction Heating and Inverter Technology
Keywords
wireless power transfer, misalignment tolerance, biomedical implants, power transfer efficiency, 40 MHz

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Wireless Power Transfer System With High Misalignment Tolerance for Bio-Medical Implants. https://app.cochat.ai/papers/10.1109/tcsii.2020.2985056
The paper
Wang, Q., Che, W., Mongiardo, M., & Monti, G. (2020). Wireless Power Transfer System With High Misalignment Tolerance for Bio-Medical Implants. IEEE Transactions on Circuits and Systems II: Express Briefs. https://doi.org/10.1109/tcsii.2020.2985056