The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Data-Driven Process Monitoring Based on Modified Orthogonal Projections to Latent Structures
Abstract
Quality- or output-related fault detection has attracted much attention in recent years. Several approaches have been developed to solve this issue based on postprocessing schemes. However, further studies find that these methods gradually lose their functions when amplitudes of quality-unrelated faults increase; in addition, they still consume a relatively large amount of calculation load in practice. In this brief, we propose a new structure of preprocessing-modeling-postprocessing, within which modified orthogonal projections to latent structures (MOPLS) method is developed. Compared with the previous approaches, the new method significantly improves the performance of quality-related fault detection. In addition, it reduces the number of required latent variables, thus it has a quite lower computational load than the previous ones. A numerical example and the Tennessee Eastman process are used to verify the effectiveness of the proposed approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Orthogonal projections to latent structures (O‐PLS)
Trygg, J., & Wold, S. (2002) · Journal of Chemometrics · doi:10.1002/cem.695 · Cited by 2,447
Survey on data-driven industrial process monitoring and diagnosis
Qin, S. J. (2012) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2012.09.004 · Cited by 1,470
Yin, S., Ding, S. X., Haghani, A., Hao, H., & Zhang, P. (2012) · Journal of Process Control · doi:10.1016/j.jprocont.2012.06.009 · Cited by 1,294
Self-citationMultivariate Control Charts for Individual Observations
Tracy, N. D., Young, J. C., & Mason, R. L. (1992) · Journal of Quality Technology · doi:10.1080/00224065.1992.12015232 · Cited by 597
Valle, S., Li, W., & Qin, S. J. (1999) · Industrial & Engineering Chemistry Research · doi:10.1021/ie990110i · Cited by 549
Total projection to latent structures for process monitoring
Zhou, D., Li, G., & Qin, S. J. (2010) · AIChE Journal · doi:10.1002/aic.11977 · Cited by 472
Dayal, B. S., & MacGregor, J. F. (1997) · Journal of Chemometrics · doi:10.1002/(sici)1099-128x(199701)11:1<73::aid-cem435>3.0.co;2-# · Cited by 400
Geometric properties of partial least squares for process monitoring
Li, G., Qin, S. J., & Zhou, D. (2010) · Automatica · doi:10.1016/j.automatica.2009.10.030 · Cited by 368
Monitoring, fault diagnosis, fault-tolerant control and optimization: Data driven methods
MacGregor, J., & Cinar, A. (2012) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2012.06.017 · Cited by 277
Zhang, K., Hao, H., Chen, Z., Ding, S. X., & Peng, K. (2015) · Journal of Process Control · doi:10.1016/j.jprocont.2015.06.007 · Cited by 193
Enhanced quality-related fault detection approach based on OSC and M-PLS
Wang, G., & Yin, S. (2015) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2015.2396853 · Cited by 162
Self-citationNadler, B., & Coifman, R. R. (2005) · Journal of Chemometrics · doi:10.1002/cem.915 · Cited by 120
Study on modifications of PLS approach for process monitoring
Yin, S., Ding, S. X., Zhang, P., Hagahni, A., & Naik, A. S. (2011) · IFAC Proceedings Volumes · doi:10.3182/20110828-6-it-1002.02876 · Cited by 104
Self-citationBiagioni, D., Astling, D. P., Graf, P. A., & Davis, M. F. (2011) · Journal of Chemometrics · doi:10.1002/cem.1398 · Cited by 18
Cited by
A new convolutional neural network-based data-driven fault diagnosis method
Wen, L., Li, X., Gao, L., & Zhang, Y. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2774777 · Cited by 2,222
Diez-Olivan, A., Del Ser, J., Galar, D., & Sierra, B. (2019) · Information Fusion · doi:10.1016/j.inffus.2018.10.005 · Cited by 633
A Data-Driven Design for Fault Detection of Wind Turbines Using Random Forests and XGboost
Zhang, D., Qian, L., Mao, B., Huang, C., Huang, B., & Si, Y. (2018) · IEEE Access · doi:10.1109/access.2018.2818678 · Cited by 583
A Review on Recent Development of Spacecraft Attitude Fault Tolerant Control System
Yin, S., Xiao, B., Ding, S. X., & Zhou, D. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2530789 · Cited by 430
Self-citationA Robust Observer-Based Sensor Fault-Tolerant Control for PMSM in Electric Vehicles
Kommuri, S. K., Defoort, M., Karimi, H. R., & Veluvolu, K. C. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2590993 · Cited by 408
Metadata
- Authors
- Yin, S., Wang, G., & Gao, H.
- Venue
- IEEE Transactions on Control Systems Technology
- Published
- 2016-07
- Volume
- 24
- Issue
- 4
- Pages
- 1480-1487
- ISSN
- 1063-6536 (ISSN-L)
- 1558-0865
- OpenAlex
- W2413579316
- Cited by
- 258
- References
- 14
- FWCI
- 47.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.