Continuous Prediction of Lower-Limb Kinematics From Multi-Modal Biomedical Signals
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The fast-growing techniques of measuring and fusing multi-modal biomedical signals enable advanced motor intent decoding schemes of lower-limb exoskeletons, meeting the increasing demand for rehabilitative or assistive applications of take-home healthcare. Challenges of exoskeletons’ motor intent decoding schemes remain in making a continuous prediction to compensate for the hysteretic response caused by mechanical transmission. In this paper, we solve this problem by proposing an ahead-of-time continuous prediction of lower-limb kinematics, with the prediction of knee angles during level walking as a case study. Firstly, an end-to-end kinematics prediction network(KinPreNet),1consisting of a feature extractor and an angle predictor, is proposed and experimentally compared with features and methods traditionally used in ahead-of-time prediction of gait phases. Secondly, inspired by the electromechanical delay(EMD), we further explore our algorithm’s capability of compensating response delay of mechanical transmission by validating the performance of the different sections of prediction time. And we experimentally reveal the time boundary of compensating the hysteretic response. Thirdly, a comparison of employing EMG signals or not is performed to reveal the EMG and kinematic signals’ collaborated contributions to the continuous prediction. During the experiments, EMG signals of nine muscles and knee angles calculated from inertial measurement unit (IMU) signals are recorded from ten healthy subjects. Our algorithm can predict knee angles with the averaged RMSE of 3.98 deg which is better than the 15.95-deg averaged RMSE of utilizing the traditional methods of ahead-of-time prediction. The best prediction time is in the interval of 27ms and 108ms. To the best of our knowledge, this is the first study of continuously predicting lower-limb kinematics in an ahead-of-time manner based on the electromechanical delay (EMD).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216 · cited 1×
“Joint angles were calculated using the joint axes of the inverse kinematics model and the generalized coordinates of the adjacent segments [41, 44].”
MethodA gait analysis data collection and reduction technique
Davis, R. B., Õunpuu, S., Tyburski, D., & Gage, J. R. (1991) · Human Movement Science · doi:10.1016/0167-9457(91)90046-z · Cited by 3,086 · cited 1×
“The coordinate system of each segment was set according to the definition of anatomical orientations and the placement of markers [39, 40].”
MethodHuang, H., Zhang, F., Hargrove, L. J., Dou, Z., Rogers, D. R., & Englehart, K. B. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2161671 · Cited by 542 · cited 5×
“made aheadof-time prediction of discrete information using four timedomain features [26].”
BackgroundMethodInfluentialA Survey on Access Control in the Age of Internet of Things
Qiu, J., Tian, Z., Du, C., Zuo, Q., Su, S., & Fang, B. (2020) · IEEE Internet of Things Journal · doi:10.1109/jiot.2020.2969326 · Cited by 458
Awad, L. N., Kudzia, P., Revi, D. A., Ellis, T. D., & Walsh, C. J. (2020) · IEEE Open Journal of Engineering in Medicine and Biology · doi:10.1109/ojemb.2020.2984429 · Cited by 111
Cited by
Interactive Control of Lower Limb Exoskeleton Robots: A Review
Zhang, Y.-P., Cao, G.-Z., Li, L.-L., & Diao, D.-F. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3352005 · Cited by 58
“Another is to use human bioelectrical signals, including EEG [73], [74], [75], [76], [77] and sEMG [78], [79], [80], [81], [82].”
MethodDeep Learning Approaches for Enhanced Lower-Limb Exoskeleton Control: A Review
Belal, M., Alsheikh, N., Aljarah, A., & Hussain, I. (2024) · IEEE Access · doi:10.1109/access.2024.3414175 · Cited by 42
“Furthermore, two novel neural networks for knee joint angle prediction were introduced in [126] and [127].”
BackgroundTransferable multi-modal fusion in knee angles and gait phases for their continuous prediction
Guo, Z., Zheng, H., Wu, H., Zhang, J., Zhou, G., & Long, J. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/accd22 · Cited by 18
Metadata
- Authors
- Yi, C., Jiang, F., Zhang, S., Guo, H., Yang, C., Ding, Z., Wei, B., Lan, X., & Zhou, H.
- Venue
- IEEE Transactions on Circuits and Systems for Video Technology
- Published
- 2022-05
- Volume
- 32
- Issue
- 5
- Pages
- 2592-2602
- ISSN
- 1051-8215 (ISSN-L)
- 1558-2205
- OpenAlex
- W3144653585
- Cited by
- 49
- References
- 5
- FWCI
- 2.03
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.