The DOI matches its Crossref record; 12 of the 13 references it cites were found in a registry or an index.
A gait analysis data collection and reduction technique
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216
Greenwood, D. T. (1965) · Medical Entomology and Zoology · Cited by 660
Justification of triaxial goniometer for the measurement of joint rotation
Chao, E. Y. S. (1980) · Journal of Biomechanics · doi:10.1016/0021-9290(80)90044-5 · Cited by 355
The anthropometry of the manual work space for the seated subject
Dempster, W. T., Gabel, W. C., & Felts, W. J. L. (1959) · American Journal of Physical Anthropology · doi:10.1002/ajpa.1330170405 · Cited by 253
Walking patterns of men with parkinsonism.
Mp, M., Sb, S., Gm, G., & Wj, D. (1978) · PubMed · Cited by 199
Anatomic Guide for the Electromyographer
Tichauer, E. R. (1977) · Journal of Occupational and Environmental Medicine · doi:10.1097/00043764-197712000-00042 · Cited by 193
Pre- and Postoperative Gait Analysis in Patients with Spastic Diplegia: A Preliminary Report
Gage, J. R., Fabian, D., Hicks, R. R., & Tashman, S. (1984) · Journal of Pediatric Orthopaedics · doi:10.1097/01241398-198411000-00012 · Cited by 120
Self-citationMeasurement of Gait Movements from Motion Picture Film
Sutherland, D. H., & Hagy, J. L. (1972) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-197254040-00009 · Cited by 105
Comment on criteria for patient evaluation tools
Brand, R. A., & Crowninshield, R. D. (1981) · Journal of Biomechanics · doi:10.1016/0021-9290(81)90093-2 · Cited by 70
Gait analysis for decision-making in cerebral palsy.
Gage, J. R. (1983) · PubMed · Cited by 60
Self-citation
Cited by
Wu, G., Siegler, S., Allard, P., Kirtley, C., Leardini, A., Rosenbaum, D., Whittle, M., D’Lima, D. D., Cristofolini, L., Witte, H., et al. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00222-6 · Cited by 3,242
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216
Human movement analysis using stereophotogrammetry
Leardini, A., Chiari, L., Croce, U. D., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.002 · Cited by 1,239
Human motion tracking for rehabilitation-A survey
Zhou, H., & Hu, H. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.09.001 · Cited by 813
Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait
Blaya, J. A., & Herr, H. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.823266 · Cited by 741
“The data were processed at 120 Hz with VICON Workstation [42] using the standard model of the lower limbs included with the software [43]–[45].”
Method
Metadata
- Authors
- Davis, R. B., Õunpuu, S., Tyburski, D., & Gage, J. R.
- Affiliations
- Newmarket Hospital (GB)
- Corresponding author
- Davis, Roy B.
- Venue
- Human Movement Science
- Publisher
- Elsevier BV
- Published
- 1991-10
- Volume
- 10
- Issue
- 5
- Pages
- 575-587
- ISSN
- 0167-9457 (ISSN-L)
- OpenAlex
- W2049223406
- Cited by
- 3,086
- References
- 13
- Citations by year
- 2026: 121 · 2025: 162 · 2024: 153 · 2023: 157 · 2022: 166 · 2021: 177 · 2020: 179 · 2019: 175 · 2018: 187 · 2017: 165 · 2016: 167 · 2015: 155 · 2014: 151 · 2013: 142 · 2012: 126
- FWCI
- 2.14
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Human Movement Science (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
- Physical Sciences › Engineering › Biomedical Engineering › Mechanics and Biomechanics Studies
- Keywords
- gait analysis, motion capture, retroreflective markers, joint kinetics, force plate, electromyography, data reduction, human locomotion
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A gait analysis data collection and reduction technique. https://app.cochat.ai/papers/10.1016/0167-9457(91)90046-z
- The paper
- Davis, R. B., Õunpuu, S., Tyburski, D., & Gage, J. R. (1991). A gait analysis data collection and reduction technique. Human Movement Science. https://doi.org/10.1016/0167-9457(91)90046-z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.