The DOI matches its Crossref record.
Relation between space charge accumulation and partial discharge activity in enameled wires under PWM-like voltage waveforms
Abstract
It has been observed that voltage waveforms generated by power electronic converters may affect significantly the reliability of electric motor insulation. Since partial discharges are considered to be the main cause of the reliability loss, new enamel insulations for magnet wires are being developed in order to withstand better stress amplification. The electrical characterization of these insulating materials is often carried out through aging tests which may provide estimation of life under different stress levels and conditions. However, deeper investigation of aging phenomena due to supply voltage waveforms is needed, especially regarding the relation between aging factors and stress conditions. This paper deals with this topic, showing experimental evidences of relation between partial discharge quantities (e.g., inception voltage, repetition frequency, amplitude) and electrical properties, associated with charge accumulation, which can be directly evaluated through space charge measurements. Characterization of insulating materials and comparison of materials candidate for application in power electronic waveform environment can be carried out resorting to the methodology proposed here. This approach can provide, therefore, a useful feedback to wire manufacturers regarding, e.g., the choice of additive nature and enamel components for magnet wires in power-electronic controlled motors.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
A reduction in PD amplitude can be found in the frequency range of 50 Hz-1 kHz.
“Another work in [157] reported that the reduction in PD amplitude can be found in the frequency range of 50 Hz-1 kHz.”
From State of the Art of Solid-State Transformers: Advanced Topologies, Implementation Issues, Recent Progress and Improvements (2020) · cites this paper as [157]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 27
- bellomo, 1996, Etude des Consequences des Nouvelles Formes de Commande sur les Materiaux de l'Isolation Statorique
- 0, Evaluation of Electrical Stresses Produced by Repetitive Impulses Part 1 General methods of evaluation of electrical endurance (lEC 98–160 CDV) Part 2 State of the art report (62068–2 (2001–08))
- montanari, 1998, Space charges as a trigger for electrical aging of polymeric insulation, Charges In Solid Dielectrics, 259
- 10.1109/94.556559 · DOI
- 10.1109/94.798112 · DOI
- 10.1109/14.2384 · DOI
- 10.1109/94.556555 · DOI
- 10.1109/TDEI.2003.1194099 · DOI
- 1983, Standard Methods for Testing Film-Insulated Magnet Wire, Annual Book of ASTM Standards, 1 3
- 10.1109/94.469986 · DOI
- 10.1109/57.537190 · DOI
- seanor, 1982, Electrical Properties of Polymers
- 10.1109/57.637150 · DOI
- hudon, 2000, Testing of Low-voltage Motor Turn Insulation Intended for Pulse-width Modulated Application, IEEE Trans Dielectr Electr Insul, 7, 783, 10.1109/94.891989 · DOI
- 10.1109/ICSD.2001.955625 · DOI · Paper page
- 10.1109/57.925300 · DOI
- yin, 1995, Critical Factors for Early Failure of Magnet Wires in Inverted-Fed Motors, IEEE CEIDP, 258
- 10.1109/28.703971 · DOI
- foulon, 1997, Investigation of the Failure Mechanism of Insulation Subjected to Repetitive Fast Voltage Surges, IEEE EIC and EMCW, 401
- 10.1109/57.400762 · DOI
- 10.1109/TDEI.2002.1007695 · DOI
- 10.1109/94.839341 · DOI
- 10.1109/CEIDP.2001.963555 · DOI
- 10.1109/ISEIM.2001.973755 · DOI
- fabiani, 2002, Accelerated degradation of ac-motor winding insulation due to voltage waveforms generated by adjustable speed drives
- 10.1109/14.2365 · DOI
- jing, 1993, Surface Charge Accumulation in SF6
Cited by
Sorted by citations
Hannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
“In addition, the reverse electric field and reversal moment of voltage polarity increase PD phenomenon [158].”
BackgroundHu, B., Wei, Z., You, H., Na, R., Liu, R., Xiong, H., Fu, P., Zhang, J., & Wang, J. (2021) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2021.3069780 · Cited by 45
Metadata
- Authors
- Fabiani, D., Montanari, G. C., Cavallini, A., & Mazzanti, G.
- Affiliations
- University of Bologna (IT)
- Venue
- IEEE Transactions on Dielectrics and Electrical Insulation
- Published
- 2004-06
- Volume
- 11
- Issue
- 3
- Pages
- 193-205
- ISSN
- 1070-9878 (ISSN-L)
- OpenAlex
- W2164055808
- Cited by
- 289
- References
- 0
- Citations by year
- 2026: 7 · 2025: 16 · 2024: 21 · 2023: 16 · 2022: 14 · 2021: 20 · 2020: 15 · 2019: 16 · 2018: 13 · 2017: 19 · 2016: 20 · 2015: 6 · 2014: 19 · 2013: 16 · 2012: 9
- FWCI
- 4.37
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Dielectrics and Electrical Insulation (publishedVersion)
- Archivio istituzionale della ricerca (Alma Mater Studiorum Università di Bologna) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › High voltage insulation and dielectric phenomena
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Transformer Diagnostics and Insulation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electromagnetic Compatibility and Noise Suppression
- Keywords
- space charge accumulation, partial discharge, power converters, electric motor insulation, insulation degradation, inception voltage, stress amplification
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review