CoChat

A Partial Discharge Study of Medium-Voltage Motor Winding Insulation Under Two-Level Voltage Pulses With High Dv/Dt

Open access
Hu, Boxue, Wei, Zhuo, You, Haoyang, Na, Risha, Liu, Rui, Xiong, Han, Fu, Pengyu, Zhang, Julia, Wang, Jin · 2021 · IEEE Open Journal of Power Electronics

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

Abstract

Medium-voltage (e.g., 10 kV rated) silicon carbide (SiC) devices have great potentials in medium-voltage variable speed drives. But their high switching dv/dt can increase the voltage stress on motor windings and cause partial discharges. This paper presents a partial discharge study of a medium-voltage form-wound winding under two-level square-wave voltage pulses. A 10 kV SiC device-based test platform is built to generate voltage pulses with high dv/dt. A three-step test approach is proposed and employed to systematically investigate the effects of various voltage parameters on partial discharges. These include voltage rise/fall time, voltage pulse width, pulse repetitive rate, duty ratio, voltage polarity, fundamental frequency, and modulation index. Partial discharge inception voltages (PDIVs) and repetitive partial discharge inception voltages (RPDIVs) of the sample are measured with varied voltage parameters. Test results show that voltage rise/fall time is a major affecting factor which reduces PDIVs of the winding sample by 6.5% when it decreases from 800 ns to 100 ns. Based on test results, a hypothetical partial discharge mechanism is presented to explain the effects of fast voltage rise/fall edges. An empirical equation is also derived to estimate PDIVs of a winding sample under various voltage rise/fall time and pulse width conditions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/ojpel.2021.3069780

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Figures

FIGURE 1. An overview of the partial discharge test platform.
FIGURE 1. An overview of the partial discharge test platform.CC BY · PubMed Central
FIGURE 2. Circuit diagram of the voltage pulse generator.
FIGURE 2. Circuit diagram of the voltage pulse generator.CC BY · PubMed Central
FIGURE 3. Voltage pulse waveforms applied to the winding sample.
FIGURE 3. Voltage pulse waveforms applied to the winding sample.CC BY · PubMed Central
FIGURE 4. Dimensions of the 2 kV form-wound coil sample.
FIGURE 4. Dimensions of the 2 kV form-wound coil sample.CC BY · PubMed Central
FIGURE 5. A cross-sectional view of the form-wound coil.
FIGURE 5. A cross-sectional view of the form-wound coil.CC BY · PubMed Central
FIGURE 6. Connection to the test sample.
FIGURE 6. Connection to the test sample.CC BY · PubMed Central
FIGURE 7. Circuit diagram for evaluating antenna-based detection method.
FIGURE 7. Circuit diagram for evaluating antenna-based detection method.CC BY · PubMed Central
FIGURE 8. Test waveforms with a 4.3 kV voltage pulse applied to the test sample.
FIGURE 8. Test waveforms with a 4.3 kV voltage pulse applied to the test sample.CC BY · PubMed Central
FIGURE 9. Circuit diagram for validating test setup free of partial discharges.
FIGURE 9. Circuit diagram for validating test setup free of partial discharges.CC BY · PubMed Central
FIGURE 10. An overview of the three-step test approach.
FIGURE 10. An overview of the three-step test approach.CC BY · PubMed Central
FIGURE 11. Test procedure for single pulse tests.
FIGURE 11. Test procedure for single pulse tests.CC BY · PubMed Central
FIGURE 12. Test procedure for repetitive and sine-PWM pulse tests.
FIGURE 12. Test procedure for repetitive and sine-PWM pulse tests.CC BY · PubMed Central
FIGURE 13. A partial discharge test waveform example under single voltage pulse.
FIGURE 13. A partial discharge test waveform example under single voltage pulse.CC BY · PubMed Central
FIGURE 14. PDIVs of the test sample under single voltage pulses.
FIGURE 14. PDIVs of the test sample under single voltage pulses.CC BY · PubMed Central
FIGURE 15. Effects of voltage rise/fall time in repetitive pulse tests (fsw = 5 kHz, d = 0.5, and unipolar voltage).
FIGURE 15. Effects of voltage rise/fall time in repetitive pulse tests (fsw = 5 kHz, d = 0.5, and unipolar voltage).CC BY · PubMed Central
FIGURE 16. Effects of pulse repetitive rate and duty ratio in repetitive pulse tests (trf = 100 ns and unipolar voltage).
FIGURE 16. Effects of pulse repetitive rate and duty ratio in repetitive pulse tests (trf = 100 ns and unipolar voltage).CC BY · PubMed Central
FIGURE 17. Effects of voltage polarity in repetitive pulse tests (fsw = 5 kHz and trf = 100 ns).
FIGURE 17. Effects of voltage polarity in repetitive pulse tests (fsw = 5 kHz and trf = 100 ns).CC BY · PubMed Central
FIGURE 18. RPDIVs of the test sample under sine-PWM pulses (fsw = 5 kHz, trf = 100 ns and bipolar voltage).
FIGURE 18. RPDIVs of the test sample under sine-PWM pulses (fsw = 5 kHz, trf = 100 ns and bipolar voltage).CC BY · PubMed Central
FIGURE 19. Partial discharge process during a voltage rise edge.
FIGURE 19. Partial discharge process during a voltage rise edge.CC BY · PubMed Central
FIGURE 20. Comparison between fast and slow voltage rise edges.
FIGURE 20. Comparison between fast and slow voltage rise edges.CC BY · PubMed Central
FIGURE 21. Partial discharge process during a voltage fall edge.
FIGURE 21. Partial discharge process during a voltage fall edge.CC BY · PubMed Central
FIGURE 22. A comparison between fast and slow voltage fall edges.
FIGURE 22. A comparison between fast and slow voltage fall edges.CC BY · PubMed Central
FIGURE 23. Single pulse test results with linear interpolations.
FIGURE 23. Single pulse test results with linear interpolations.CC BY · PubMed Central
FIGURE 24. Comparison between test results and equation calculation results.
FIGURE 24. Comparison between test results and equation calculation results.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 33 references

Research works printed but not linked: 2

  1. Stone GC, Sedding HG, and Chan C, “ Experience with online partial-discharge measurement in high-voltage inverter-fed motors,” in IEEE Trans. Ind. Appl, vol. 54, no. 1, pp. 866– 872, 1./Feb. 2018. · DOI
  2. Nojima G, “ 10 kV integrated SiC VSD and High-speed motor for gas compression systems,” in Proc. US DOE Adv. Manuf. Office Prog. Rev. Meet., WA, DC, USA, 6. 2019.

Cited by

See all 52

Metadata

Authors
Hu, B., Wei, Z., You, H., Na, R., Liu, R., Xiong, H., Fu, P., Zhang, J., & Wang, J.
Affiliations
The Ohio State University (US)
Venue
IEEE Open Journal of Power Electronics
Published
2021
Volume
2
Pages
225-235
ISSN
2644-1314 (ISSN-L)
OpenAlex
W3144785757
Cited by
45
References
33
Citations by year
2026: 7 · 2025: 8 · 2024: 10 · 2023: 9 · 2022: 9 · 2021: 2
FWCI
2.28
Type
journal article
Language
en
Open access
Locations
  • IEEE Open Journal of Power Electronics (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Glenn Research Center (#NNX17AJ92A)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › High voltage insulation and dielectric phenomena
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electromagnetic Compatibility and Noise Suppression
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Silicon Carbide Semiconductor Technologies
Keywords
partial discharge, silicon carbide devices, dv/dt, partial discharge inception voltage, variable frequency drive, pulse duration, duty cycle

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Partial Discharge Study of Medium-Voltage Motor Winding Insulation Under Two-Level Voltage Pulses With High Dv/Dt. https://app.cochat.ai/papers/10.1109/ojpel.2021.3069780
The paper
Hu, B., Wei, Z., You, H., Na, R., Liu, R., Xiong, H., Fu, P., Zhang, J., & Wang, J. (2021). A Partial Discharge Study of Medium-Voltage Motor Winding Insulation Under Two-Level Voltage Pulses With High Dv/Dt. IEEE Open Journal of Power Electronics. https://doi.org/10.1109/ojpel.2021.3069780

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.