The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Comparison of the Response of Doubly Fed and Fixed-Speed Induction Generator Wind Turbines to Changes in Network Frequency
Abstract
Synchronous and fixed-speed induction generators release the kinetic energy of their rotating mass when the power system frequency is reduced. In the case of doubly fed induction generator (DFIG)-based wind turbines, their control system operates to apply a restraining torque to the rotor according to a predetermined curve with respect to the rotor speed. This control system is not based on the power system frequency and there is negligible contribution to the inertia of the power system. A DFIG control system was modified to introduce inertia response to the DFIG wind turbine. Simulations were used to show that with the proposed control system, the DFIG wind turbine can supply considerably greater kinetic energy than a fixed-speed wind turbine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Erinmez, I. A., Bickers, D. O., Wood, G. F., & Hung, W. W. (1999) · IEEE Power Engineering Society Winter Meeting · doi:10.1109/pesw.1999.747521 · Cited by 72
Cited by
Definition and Classification of Power System Stability – Revisited & Extended
Hatziargyriou, N., Milanovic, J., Rahmann, C., Ajjarapu, V., Canizares, C., Erlich, I., Hill, D., Hiskens, I., Kamwa, I., Pal, B., et al. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.3041774 · Cited by 1,244
High-power wind energy conversion systems: State-of-the-art and emerging technologies
Yaramasu, V., Wu, B., Sen, P. C., Kouro, S., & Narimani, M. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2378692 · Cited by 991
Inertia response and frequency control techniques for renewable energy sources: A review
Dreidy, M., Mokhlis, H., & Mekhilef, S. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.11.170 · Cited by 853
The Relevance of Inertia in Power Systems
Tielens, P., & Van Hertem, D. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.11.016 · Cited by 809
Delille, G., Francois, B., & Malarange, G. (2012) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2012.2205025 · Cited by 776
Virtual synchronous generators
Driesen, J., & Visscher, K. (2008) · 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century · doi:10.1109/pes.2008.4596800 · Cited by 763
Frequency Control and Wind Turbine Technologies
Lalor, G., Mullane, A., & O'Malley, M. (2005) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.857393 · Cited by 698
Participation of Doubly Fed Induction Wind Generators in System Frequency Regulation
de Almeida, R. G., & Pecas Lopes, J. A. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2007.901096 · Cited by 576
Pandey, S. K., Mohanty, S. R., & Kishor, N. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.04.029 · Cited by 561
Frequency support from doubly fed induction generator wind turbines
Ramtharan, G., Jenkins, N., & Ekanayake, J. B. (2007) · IET Renewable Power Generation · doi:10.1049/iet-rpg:20060019 · Cited by 530
Self-citationDynamic Contribution of DFIG-Based Wind Plants to System Frequency Disturbances
Kayikci, M., & Milanovic, J. V. (2009) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2016062 · Cited by 462
Inertial response of variable speed wind turbines
Morren, J., Pierik, J., & de Haan, S. W. H. (2006) · Electric Power Systems Research · doi:10.1016/j.epsr.2005.12.002 · Cited by 459
High-Level Penetration of Renewable Energy Sources Into Grid Utility: Challenges and Solutions
Alam, M. S., Al-Ismail, F. S., Salem, A., & Abido, M. A. (2020) · IEEE Access · doi:10.1109/access.2020.3031481 · Cited by 431
Alhelou, H. H., Hamedani-Golshan, M.-E., Zamani, R., Heydarian-Forushani, E., & Siano, P. (2018) · Energies · doi:10.3390/en11102497 · Cited by 349
Kinetic Energy of Wind-Turbine Generators for System Frequency Support
Keung, P.-K., Li, P., Banakar, H., & Ooi, B. T. (2009) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2008.2004827 · Cited by 349
Gautam, D., Goel, L., Ayyanar, R., Vittal, V., & Harbour, T. (2011) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2010.2051690 · Cited by 327
Mohseni, M., & Islam, S. M. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.03.039 · Cited by 327
O'Sullivan, J., Rogers, A., Flynn, D., Smith, P., Mullane, A., & O'Malley, M. (2014) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2014.2316974 · Cited by 291
Collins, S., Deane, J. P., Poncelet, K., Panos, E., Pietzcker, R. C., Delarue, E., & Ó Gallachóir, B. P. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.03.090 · Cited by 282
An Assessment of the Impact of Wind Generation on System Frequency Control
Doherty, R., Mullane, A., Nolan, G., Burke, D. J., Bryson, A., & O'Malley, M. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2030348 · Cited by 281
Evaluation of Virtual Inertia Control Strategies for MMC-based HVDC Terminals by P-HiL Experiments
D'Arco, S., Nguyen, T. T., & Suul, J. A. (2019) · IECON 2019 - 45th Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2019.8927704 · Cited by 12
Metadata
- Authors
- Ekanayake, J., & Jenkins, N.
- Venue
- IEEE Transactions on Energy Conversion
- Published
- 2004-12
- Volume
- 19
- Issue
- 4
- Pages
- 800-802
- ISSN
- 0885-8969 (ISSN-L)
- OpenAlex
- W2031196831
- Cited by
- 641
- References
- 1
- FWCI
- 7.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.