The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
An Assessment of the Impact of Wind Generation on System Frequency Control
Open accessAbstract
Rising wind generation penetrations and the distinctive inertial characteristics of associated turbine technology will impact system frequency control. While wind production will displace conventional synchronous plant, empirical study data presented also suggest that the relationship between the total stored turbine kinetic energy and the total system power production for wind is a variable that exhibits significant nonlinearity. Changing trends in system frequency behavior of a power system following the loss of the largest generator are studied in detail here, using simplified frequency control models and extensive simulations of wind penetration scenarios over an extended multiyear timeframe. The system frequency response is characterized by the rate of change of frequency and the frequency nadir. Results show that increasing levels of doubly fed induction generators and high-voltage dc interconnection alter the frequency behavior significantly, and that system operators may have to be proactive in developing solutions to meet these challenges.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wind Turbines Emulating Inertia and Supporting Primary Frequency Control
Morren, J., de Haan, S. W. H., Kling, W. L., & Ferreira, J. A. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.861956 · Cited by 1,263
Frequency Control and Wind Turbine Technologies
Lalor, G., Mullane, A., & O'Malley, M. (2005) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.857393 · Cited by 698
Self-citationEkanayake, J., & Jenkins, N. (2004) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.827712 · Cited by 641
Kinetic Energy of Wind-Turbine Generators for System Frequency Support
Keung, P.-K., Li, P., Banakar, H., & Ooi, B. T. (2009) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2008.2004827 · Cited by 349
The Inertial Response of Induction-Machine-Based Wind Turbines
Mullane, A., & O'Malley, M. (2005) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.852081 · Cited by 309
Self-citationFrequency Control in Competitive Electricity Market Dispatch
Doherty, R., Lalor, G., & O'Malley, M. J. (2005) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.852146 · Cited by 141
Self-citationLarge static converters for industry and utility applications
Akagi, H. (2001) · Proceedings of the IEEE · doi:10.1109/5.931498 · Cited by 98
Measurement-based estimation of wind farm inertia
Littler, T., Fox, B., & Flynn, D. (2005) · doi:10.1109/ptc.2005.4524432 · Cited by 35
Cited by
Denholm, P., & Hand, M. (2011) · Energy Policy · doi:10.1016/j.enpol.2011.01.019 · Cited by 947
Role of Energy Storage with Renewable Electricity Generation
Denholm, P., Ela, E., Kirby, B., & Milligan, M. (2010) · doi:10.2172/972169 · Cited by 847
Delille, G., Francois, B., & Malarange, G. (2012) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2012.2205025 · Cited by 776
Pandey, S. K., Mohanty, S. R., & Kishor, N. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.04.029 · Cited by 561
Security-Constrained Unit Commitment With Linearized System Frequency Limit Constraints
Ahmadi, H., & Ghasemi, H. (2014) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2014.2297997 · Cited by 386
Metadata
- Authors
- Doherty, R., Mullane, A., Nolan, G., Burke, D. J., Bryson, A., & O'Malley, M.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2010-02
- Volume
- 25
- Issue
- 1
- Pages
- 452-460
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2122178982
- Cited by
- 281
- References
- 8
- FWCI
- 10.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Assessment of the Impact of Wind Generation on System Frequency Control. https://app.cochat.ai/papers/10.1109/tpwrs.2009.2030348
- The paper
- Doherty, R., Mullane, A., Nolan, G., Burke, D. J., Bryson, A., & O'Malley, M. (2010). An Assessment of the Impact of Wind Generation on System Frequency Control. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2009.2030348
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.