Reliable State Estimation of Multicell Lithium-Ion Battery Systems
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Lithium-ion (Li-ion) batteries are nowadays the best tradeoff between performance, cost, and lifetime to store electric power and energy effectively. The reliable determination of the batteries' instantaneous power capability and energy content is mandatory for many mobile high-energy and power-consuming applications. Herein, the battery impedance and state of charge (SOC) are the relevant values. In energy storage systems, these values are to be considered for each battery cell individually, due to arising limitations caused by cell-specific variations. Simple algorithms to determine the battery system's impedance and SOC are presented including parameter and state-estimation techniques. Furthermore, methods are derived making the impedance and SOC determination possible for a large number of particular cells in a battery system. The applicability of the demonstrated algorithms for battery control unit implementation is proved incorporating data achieved from load scenarios applied to a cell stack Li-ion battery module. Cell impedance and SOC variations could be detected precisely. Moreover, a combination of impedance and SOC spread was identified during typical battery operation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ageing mechanisms in lithium-ion batteries
Vetter, J., Novák, P., Wagner, M. R., Veit, C., Möller, K.-C., Besenhard, J. O., Winter, M., Wohlfahrt-Mehrens, M., Vogler, C., & Hammouche, A. (2005) · Journal of Power Sources · doi:10.1016/j.jpowsour.2005.01.006 · Cited by 3,987
Accurate electrical battery model capable of predicting runtime and I-V performance
Chen, M., & Rincon-Mora, G. A. (2006) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.874229 · Cited by 2,427 · cited 1×
“Therein, algebraic battery models are calculated simultaneously to the operating storage system [11], [12].”
MethodThe novel state of charge estimation method for lithium battery using sliding mode observer
Kim, I.-S. (2006) · Journal of Power Sources · doi:10.1016/j.jpowsour.2006.09.006 · Cited by 359 · cited 1×
“The OCV of Li-ion batteries is a function of SOC and the actual temperature θ [22], [23].”
BackgroundFuzzy logic modelling of state-of-charge and available capacity of nickel/metal hydride batteries
Singh, P., Fennie, C., & Reisner, D. (2004) · Journal of Power Sources · doi:10.1016/j.jpowsour.2004.03.035 · Cited by 117 · cited 1×
“Besides fuzzy logic systems [5]–[7], artificial neural networks [8]–[10], and expert systems [7], the model-based state and parameter estimation are one of the most promising approaches for reliable battery monitoring.”
Background
Cited by
Degradation diagnostics for lithium ion cells
Birkl, C. R., Roberts, M. R., McTurk, E., Bruce, P. G., & Howey, D. A. (2017) · Journal of Power Sources · doi:10.1016/j.jpowsour.2016.12.011 · Cited by 1,945
Waag, W., Fleischer, C., & Sauer, D. U. (2014) · Journal of Power Sources · doi:10.1016/j.jpowsour.2014.02.064 · Cited by 1,059
Self-citationNejad, S., Gladwin, D. T., & Stone, D. A. (2016) · Journal of Power Sources · doi:10.1016/j.jpowsour.2016.03.042 · Cited by 565
Zheng, Y., Ouyang, M., Han, X., Lu, L., & Li, J. (2018) · Journal of Power Sources · doi:10.1016/j.jpowsour.2017.11.094 · Cited by 490
Dai, H., Wei, X., Sun, Z., Wang, J., & Gu, W. (2012) · Applied Energy · doi:10.1016/j.apenergy.2012.02.044 · Cited by 367
Metadata
- Authors
- Roscher, M. A., Bohlen, O. S., & Sauer, D. U.
- Venue
- IEEE Transactions on Energy Conversion
- Published
- 2011-09
- Volume
- 26
- Issue
- 3
- Pages
- 737-743
- ISSN
- 0885-8969 (ISSN-L)
- 1558-0059
- OpenAlex
- W2136843013
- Cited by
- 113
- References
- 4
- FWCI
- 19.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.