The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Implemental Control Strategy for Grid Stabilization of Grid-Connected PV System Based on German Grid Code in Symmetrical Low-to-Medium Voltage Network
Abstract
In the last couple of years, the increasing penetration of renewable energy resulted in the development of grid-connected large-scale power plants. However, a high penetration harbors the risk of grid instability if the generating power plants are not able to support the grid. Therefore, grid stabilization, which depends on the system-type or grid of each country, plays an important role and has been strengthened by different grid codes. With this background, VDE-AR-N 4105 for photovoltaic (PV) systems connected to the low-voltage grid and the German Association of Energy and Water Industries (BDEW) introduced the medium-voltage grid code for connecting power plants to the grid and they are the most stringent certifications. In this paper, the control strategy of generating system is enhanced with VDE-AR-N 4105 and BDEW grid code, where both active/reactive powers are controlled. Simulation and experimental results of 100-kW PV inverter are shown to verify the effectiveness of the proposed implemental control strategy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey
Carrasco, J. M., Franquelo, L. G., Bialasiewicz, J. T., Galvan, E., PortilloGuisado, R. C., Prats, M. A. M., Leon, J. I., & Moreno-Alfonso, N. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.878356 · Cited by 4,018
Instantaneous Power Theory and Applications to Power Conditioning
Akagi, H., Watanabe, E. H., & Aredes, M. (2007) · Wiley eBooks · doi:10.1002/0470118938 · Cited by 2,234
Control of single-stage single-phase PV inverter
Ciobotaru, M., Teodorescu, R., & Blaabjerg, F. (2005) · 2005 European Conference on Power Electronics and Applications · doi:10.1109/epe.2005.219501 · Cited by 184
An overview of the present grid codes for integration of distributed generation
Preda, T. N., Uhlen, K., & Nordgård, D. E. (2012) · doi:10.1049/cp.2012.0716 · Cited by 41
Cited by
A review of key power system stability challenges for large-scale PV integration
Shah, R., Mithulananthan, N., Bansal, R. C., & Ramachandaramurthy, V. K. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.09.027 · Cited by 501
Al-Shetwi, A. Q., Hannan, M. A., Jern, K. P., Mansur, M., & Mahlia, T. M. I. (2020) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2019.119831 · Cited by 442
Low-Voltage Ride-Through of Single-Phase Transformerless Photovoltaic Inverters
Yang, Y., Blaabjerg, F., & Wang, H. (2014) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2282966 · Cited by 358
Yang, Y., Enjeti, P., Blaabjerg, F., & Wang, H. (2015) · IEEE Industry Applications Magazine · doi:10.1109/mias.2014.2345837 · Cited by 262
Afshari, E., Moradi, G. R., Rahimi, R., Farhangi, B., Yang, Y., Blaabjerg, F., & Farhangi, S. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2733481 · Cited by 259
Metadata
- Authors
- Bae, Y., Vu, T.-K., & Kim, R.-Y.
- Venue
- IEEE Transactions on Energy Conversion
- Published
- 2013-09
- Volume
- 28
- Issue
- 3
- Pages
- 619-631
- ISSN
- 0885-8969 (ISSN-L)
- 1558-0059
- OpenAlex
- W2051005341
- Cited by
- 256
- References
- 4
- FWCI
- 26.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.