The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Control Strategy for Three-Phase Grid-Connected PV Inverters Enabling Current Limitation Under Unbalanced Faults
Open accessAbstract
Power quality and voltage control are among the most important aspects of the grid-connected power converter operation under faults. Nonsinusoidal current may be injected during unbalanced voltage sag, and active or/and reactive power may include double frequency content. This paper introduces a novel control strategy to mitigate the double grid frequency oscillations in the active power and dc-link voltage of the two-stage three-phase grid-connected photovoltaic (PV) inverters during unbalanced faults. With the proposed control method, PV inverter injects sinusoidal currents under unbalanced grid faults. In addition, an efficient and easy-to-implement current limitation method is introduced, which can effectively limit the injected currents to the rated value during faults. In this case, the fault-ride-through operation is ensured, and it will not trigger the overcurrent protection. A non-maximum power point tracking (non-MPPT) operation mode is proposed for the dc-dc converter. The mode is enabled under severe faults when the converter cannot handle the maximum PV power. Finally, experimental validation is provided by implementing a method in an experimental setup, including a 2 kW PV inverter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Grid Converters for Photovoltaic and Wind Power Systems
Teodorescu, R., Liserre, M., & Rodríguez, P. (2011) · Wiley eBooks · doi:10.1002/9780470667057 · Cited by 3,344
Reliability of Capacitors for DC-Link Applications in Power Electronic Converters—An Overview
Wang, H., & Blaabjerg, F. (2014) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2014.2308357 · Cited by 1,384
Self-citationGrid Code, high and extra high voltage
Netz, E. O. (2006) · Medical Entomology and Zoology · Cited by 835
Flexible Active Power Control of Distributed Power Generation Systems During Grid Faults
Rodriguez, P., Timbus, A. V., Teodorescu, R., Liserre, M., & Blaabjerg, F. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.899914 · Cited by 726
Self-citationOverview of recent grid codes for wind power integration
Altin, M., Goksu, O., Teodorescu, R., Rodriguez, P., Jensen, B.-B., & Helle, L. (2010) · 2010 12th International Conference on Optimization of Electrical and Electronic Equipment · doi:10.1109/optim.2010.5510521 · Cited by 393
Control Strategies Based on Symmetrical Components for Grid-Connected Converters Under Voltage Dips
Alepuz, S., Busquets-Monge, S., Bordonau, J., Martinez-Velasco, J. A., Silva, C. A., Pontt, J., & Rodriguez, J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2017102 · Cited by 373
Flexible Voltage Support Control for Three-Phase Distributed Generation Inverters Under Grid Fault
Camacho, A., Castilla, M., Miret, J., Vasquez, J. C., & Alarcon-Gallo, E. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2185016 · Cited by 339
Camacho, A., Castilla, M., Miret, J., Borrell, A., & de Vicuna, L. G. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2347266 · Cited by 300
Bae, Y., Vu, T.-K., & Kim, R.-Y. (2013) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2013.2263885 · Cited by 256
A Low-Voltage Ride-Through Technique for Grid-Connected Converters of Distributed Energy Resources
Lee, C.-T., Hsu, C.-W., & Cheng, P.-T. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2155016 · Cited by 248
Cited by
Zhang, H., Xiang, W., Lin, W., & Wen, J. (2021) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2021.000257 · Cited by 529
Current Limiting Control With Enhanced Dynamics of Grid-Forming Converters During Fault Conditions
Taul, M. G., Wang, X., Davari, P., & Blaabjerg, F. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2931477 · Cited by 466
Self-citationTaul, M. G., Wang, X., Davari, P., & Blaabjerg, F. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2892142 · Cited by 415
Self-citationA Review of Current-Limiting Control of Grid-Forming Inverters Under Symmetrical Disturbances
Fan, B., Liu, T., Zhao, F., Wu, H., & Wang, X. (2022) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2022.3227507 · Cited by 371
Liu, T., Wang, X., Liu, F., Xin, K., & Liu, Y. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3122744 · Cited by 200
Metadata
- Authors
- Afshari, E., Moradi, G. R., Rahimi, R., Farhangi, B., Yang, Y., Blaabjerg, F., & Farhangi, S.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2017-11
- Volume
- 64
- Issue
- 11
- Pages
- 8908-8918
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2736644353
- Cited by
- 259
- References
- 17
- FWCI
- 7.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Control Strategy for Three-Phase Grid-Connected PV Inverters Enabling Current Limitation Under Unbalanced Faults. https://app.cochat.ai/papers/10.1109/tie.2017.2733481
- The paper
- Afshari, E., Moradi, G. R., Rahimi, R., Farhangi, B., Yang, Y., Blaabjerg, F., & Farhangi, S. (2017). Control Strategy for Three-Phase Grid-Connected PV Inverters Enabling Current Limitation Under Unbalanced Faults. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2017.2733481
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.