Comparative Performance Analysis of the Dielectrically Modulated Full- Gate and Short-Gate Tunnel FET-Based Biosensors
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
In this paper, a short-gate tunneling-field-effect-transistor (SG-TFET) structure has been investigated for the dielectrically modulated biosensing applications in comparison with a full-gate tunneling-field-effect-transistor structure of similar dimensions. This paper explores the underlying physics of these architectures and estimates their comparative sensing performance. The sensing performance has been evaluated for both the charged and charge-neutral biomolecules using extensive device-level simulation, and the effects of the biomolecule dielectric constant and charge density are also studied. In SG-TFET architecture, the reduction of the gate length enhances its drain control over the band-to-band tunneling process and this has been exploited for the detection, resulting to superior drain current sensitivity for biomolecule conjugation. The gate and drain biasing conditions show dominant impact on the sensitivity enhancement in the short-gate biosensors. Therefore, the gate and drain bias are identified as the effective design parameters for the efficiency optimization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physics of Semiconductor Devices
Sze, S. M., & Ng, K. K. (2006) · doi:10.1002/0470068329 · Cited by 14,627
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329 · cited 2×
“low power dissipation, scalability, and scope of on-chip integration [7], [8].”
BackgroundSubthreshold Regime has the Optimal Sensitivity for Nanowire FET Biosensors
Gao, X. P. A., Zheng, G., & Lieber, C. M. (2010) · Nano Letters · doi:10.1021/nl9034219 · Cited by 571
Narang, R., Reddy, K. V. S., Saxena, M., Gupta, R. S., & Gupta, M. (2012) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2012.2208115 · Cited by 308 · cited 3×
“These values are chosen following [9]–[11], [22], and [23], maintaining a uniform difference between the consecutive values for the better understanding.”
BackgroundDielectric-Modulated Impact-Ionization MOS Transistor as a Label-Free Biosensor
Kannan, N., & Kumar, M. J. (2013) · IEEE Electron Device Letters · doi:10.1109/led.2013.2283858 · Cited by 161 · cited 2×
“These values are chosen following [9]–[11], [22], and [23], maintaining a uniform difference between the consecutive values for the better understanding.”
Background
Cited by
Performance Assessment of A Novel Vertical Dielectrically Modulated TFET-Based Biosensor
Verma, M., Tirkey, S., Yadav, S., Sharma, D., & Yadav, D. S. (2017) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2017.2732820 · Cited by 276
Wangkheirakpam, V. D., Bhowmick, B., & Pukhrambam, P. D. (2020) · IEEE Transactions on Nanotechnology · doi:10.1109/tnano.2020.2969206 · Cited by 199
Dwivedi, P., & Kranti, A. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2640192 · Cited by 87
Metadata
- Authors
- Kanungo, S., Chattopadhyay, S., Gupta, P. S., & Rahaman, H.
- Venue
- IEEE Transactions on Electron Devices
- Published
- 2015-03
- Volume
- 62
- Issue
- 3
- Pages
- 994-1001
- ISSN
- 0018-9383 (ISSN-L)
- 1557-9646
- OpenAlex
- W2016695397
- Cited by
- 248
- References
- 5
- FWCI
- 3.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.