The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Provocative Testing for the Assessment of the Electromagnetic Interference of RFID and NFC Readers on Implantable Pacemaker
Abstract
The purpose of this study is to perform provocative testing for the assessment of the electromagnetic interference (EMI) of radiofrequency identification (RFID) and near field communication (NFC) readers on implantable pacemakers (PMs). Ten PMs were exposed to the electromagnetic field generated by an RFID/NFC reader emulator, in the LF (125 kHz), HF and NCF (13.56 MHz), and UHF (900 MHz) bands. Provocative tests were performed by increasing the field strength beyond the maximum levels allowed for commercial devices. PMs were affected by EMI for all three frequency bands. For the LF RFID, 2/10 PMs when exposed to magnetic field levels typical of commercial devices (100 A/m) and 9/10 PMs at a magnetic field of 500 A/m. For the HF RFID and NFC, 3/10 PMs when exposed to output power levels of magnetic field typical of commercial devices (4 W), and 7/10 PMs at 10 W. For the UHF RFID, 2/10 at output power lever of 2 W, and increasing the output power level up to 20 W did not caused EMI in the other PMs. For the PMs evaluated, the provocative tests performed in this study revealed that the safety margin is narrow in the LF and HF/NFC bands, whereas a fair margin exists in the UHF band.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Power transfer methods such as NFC or RF can conflict with frequencies used for data transfer, resulting in signal corruption that can affect diagnosis and monitoring of neurological conditions.
“These methods, while effective for power delivery, can conflict with the frequencies used for data transfer resulting in signal corruption, which can affect the diagnosis and monitoring of neurological conditions (Dobkin, 2012; Mattei et al., 2016).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Mattei et al., 2016
Citations
Cites
van der Togt, R. (2008) · JAMA · doi:10.1001/jama.299.24.2884 · Cited by 263
Seidman, S. J., Brockman, R. G., Lewis, B., Guag, J. W., Shein, M. J., Clement, W. J., Kippola, J., Digby, D., Barber, C., & Huntwork, D. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.09.071 · Cited by 98
Testing Potential Interference with RFID Usage in the Patient Care Environment
Christe, B. L., Cooney, E. M., Maggioli, G., Doty, D., Frye, R. L., & Short, J. (2008) · Biomedical Instrumentation & Technology · doi:10.2345/0899-8205-42.6.479 · Cited by 44
Houliston, B., Parry, D., Webster, C. S., & Merry, A. (2009) · PubMed · Cited by 36
Barbaro, V., Bartolini, P., Calcagnini, G., Censi, F., Beard, B. B., Ruggera, P. S., & Witters, D. M. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/11/312 · Cited by 33
Self-citationSeidman, S. J., Ruggera, P. S., Brockman, R. G., Lewis, B., & Shein, M. J. (2007) · International Journal of Radio Frequency Identification Technology and Applications · doi:10.1504/ijrfita.2007.015848 · Cited by 31
Electromagnetic compatibility of implantable neurostimulators to RFID emitters
Pantchenko, O. S., Seidman, S. J., Guag, J. W., Witters, D. M., & Sponberg, C. L. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-50 · Cited by 23
Setups forin vitroassessment of RFID interference on pacemakers
Mattei, E., Censi, F., Delogu, A., Ferrara, A., & Calcagnini, G. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/15/5301 · Cited by 16
Self-citationFutatsumori, S., Kawamura, Y., Hikage, T., Nojima, T., Koike, B., Fujimoto, H., & Toyoshima, T. (2009) · Journal of Arrhythmia · doi:10.1016/s1880-4276(09)80013-6 · Cited by 11
Seidman, S. J., Pantchenko, O. S., & Tennakoon, D. (2014) · IEEE Electromagnetic Compatibility Magazine · doi:10.1109/memc.2014.6798800 · Cited by 10
Pantchenko, O. S., Seidman, S. J., & Guag, J. W. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-94 · Cited by 6
Mattei, E., Censi, F., Triventi, M., Bartolini, P., & Calcagnini, G. (2012) · Expert Review of Medical Devices · doi:10.1586/erd.12.5 · Cited by 4
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Driessen, S., Napp, A., Schmiedchen, K., Kraus, T., & Stunder, D. (2019) · EP Europace · doi:10.1093/europace/euy155 · Cited by 76
Reconfigurable Dual-Band Bidirectional Reflection Amplifier With Applications in Van Atta Array
Farzami, F., Khaledian, S., Smida, B., & Erricolo, D. (2017) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2017.2701832 · Cited by 60
Comparative analysis of energy transfer mechanisms for neural implants
Miziev, S., Pawlak, W. A., & Howard, N. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1320441 · Cited by 21
Mattei, E., Censi, F., Calcagnini, G., & Falsaperla, R. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18189709 · Cited by 11
Self-citationOpSecure: A Secure Unidirectional Optical Channel for Implantable Medical Devices
Mosenia, A., & Jha, N. K. (2017) · IEEE Transactions on Multi-Scale Computing Systems · doi:10.1109/tmscs.2017.2771347 · Cited by 10
Mattei, E., Calcagnini, G., Censi, F., Pinto, I., Bogi, A., & Falsaperla, R. (2019) · Environments · doi:10.3390/environments6110119 · Cited by 9
Self-citationElectromagnetic Safety of Short-Range Radio Frequency Identification Systems
Musiał, S., Firlej, A., Kubiak, I., & Dalecki, T. (2023) · Electronics · doi:10.3390/electronics12214391 · Cited by 7
Napp, A., Kolb, C., Lennerz, C., Bauer, W., Schulz‐Menger, J., Kraus, T., Marx, N., & Stunder, D. (2019) · Der Kardiologe · doi:10.1007/s12181-019-0335-0 · Cited by 7
Firlej, A., Musiał, S., & Kubiak, I. (2024) · Applied Sciences · doi:10.3390/app14135854 · Cited by 5
Investigating the Effect of Temperature in RFID Technology
Kim, T.-H., Mapa, L., Ramamurthy, D., & Goni, F. (2018) · ASEE Annual Conference & Exposition · doi:10.18260/1-2--28589 · Cited by 5
A Framework for Automated NFC Interoperability Test Systems
Erb, M., Steger, C., Troyer, M., & Preishuber‐Pfluegl, J. (2021) · IEEE Journal of Radio Frequency Identification · doi:10.1109/jrfid.2021.3093589 · Cited by 5
Vivarelli, C., Mattei, E., Ricci, F., D'Eramo, S., & Calcagnini, G. (2025) · Bioengineering · doi:10.3390/bioengineering12070689 · Cited by 3
Self-citationKim, J., Kwon, J., Kim, J., Jeong, M., Bae, S., & Lee, W. (2017) · Progress In Electromagnetics Research C · doi:10.2528/pierc17040802 · Cited by 3
Constantinescu, C., Pacurar, C., Andreica, S., Gliga, M., Grindei, L., Rápolti, L., Terec, D., & Giurgiuman, A. (2026) · Technologies · doi:10.3390/technologies14010051 · Cited by 2
TiDoSGAN: Enhanced Generative Adversarial Network for NFC Restoration
Lee, S., Joo, H., & Kim, H. (2025) · IEEE Internet of Things Journal · doi:10.1109/jiot.2025.3587697 · Cited by 2
Towards Fully Interoperable NFC Devices
Erb, M., Steger, C., Troyer, M., & Preishuber‐Pfluegl, J. (2020) · IEEE International Conference on RFID · doi:10.1109/rfid49298.2020.9244914 · Cited by 2
Senevirathna, N., Kleihorst, R., van den Berg, B., & Versteegen, D. (2025) · IEEE Letters on Electromagnetic Compatibility Practice and Applications · doi:10.1109/lemcpa.2025.3593820 · Cited by 1
13.56 MHz RFID Module – From Application to Process Modelling and Effects on Human Health
Constantinescu, C., Pacurar, C., Giurgiuman, A., Munteanu, C., Andreica, S., Gliga, M., & Dușa, S. (2025) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-95671-3_22 · Cited by 1
Framework to Develop the Customized Tool for RFID Experiment
Kim, T.-H., Mapa, L., & Jun, M. H. (2020) · ASEE Annual Conference & Exposition · doi:10.18260/1-2--30536
NFC Coils with Resistance Sensitivity for Wearable Applications
Huang, M., & Xu, L. (2024) · IEEE International Conference on Computational Electromagnetics · doi:10.1109/iccem60619.2024.10558898
Zhou, M., Kourtiche, D., Claudel, J., Nadi, M., Roth, P., Magne, I., & Deschamps, F. (2024) · Radioprotection · doi:10.1051/radiopro/2024060
Metadata
- Authors
- Mattei, E., Lucano, E., Censi, F., Triventi, M., & Calcagnini, G.
- Affiliations
- Istituto Superiore di Sanità (IT)
- Sapienza University of Rome (IT)
- Venue
- IEEE Transactions on Electromagnetic Compatibility
- Published
- 2016-02
- Volume
- 58
- Issue
- 1
- Pages
- 314-322
- ISSN
- 0018-9375 (ISSN-L)
- 1558-187X
- OpenAlex
- W2290054612
- Cited by
- 22
- References
- 12
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 4 · 2023: 1 · 2021: 3 · 2020: 2 · 2019: 2 · 2018: 2 · 2017: 3
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Electromagnetic Compatibility (publishedVersion)
- IRIS Research product catalog (Sapienza University of Rome) (submittedVersion)
- Topics
- Physical Sciences › Computer Science › Computer Networks and Communications › RFID technology advancements
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electromagnetic Compatibility and Measurements
- Keywords
- electromagnetic interference, implantable pacemaker, RFID reader, near field communication, provocation tests, magnetic field exposure, HF RFID, UHF RFID, safety margin, pacemaker safety
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review