Assessment of Human Exposure to Electromagnetic Fields: Review and Future Directions
Open accessThe DOI matches its Crossref record; 87 of the 87 references it cites were found in a registry or an index.
Abstract
This article reviews recent standardization activities and scientific studies related to the assessment of human exposure to electromagnetic fields (EMF). The differences of human exposure standards and assessment of consumer products and medical applications are summarized. First, we reviewed human body modeling and tissue dielectric properties. Then, we explain the rationale of current exposure standards from the viewpoint of EMF and the standardization process for product compliance based on these exposure standards. The assessment of wireless power transfer, as an example of emerging wireless devices, and environmental EMFs in our daily lives are reviewed. Safety in magnetic resonance systems, where the EMF exposure is much larger than from typical consumer devices, is also reviewed. Finally, we summarize future research directions and research needs for EMF safety.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A survey on deep learning in medical image analysis
Litjens, G., Kooi, T., Bejnordi, B. E., Setio, A. A. A., Ciompi, F., Ghafoorian, M., van der Laak, J. A. W. M., van Ginneken, B., & Sánchez, C. I. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.07.005 · Cited by 15,332 · cited 1×
“Recent developments in artificial intelligence, particularly deep learning, has led to remarkable breakthroughs in several medical imaging and signal processing applications [20].”
Resonance Absorption by Nuclear Magnetic Moments in a Solid
Purcell, E. M., Torrey, H. C., & Pound, R. V. (1946) · Physical Review · doi:10.1103/physrev.69.37 · Cited by 6,053 · cited 1×
“First described experimentally in 1946 [114], MRI has become ‘ the ’ diagnostic imaging tool with over 100 million examinations performed worldwide in 2020 [115].”
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,270 · cited 2×
“Conventionally, tissue conductivity values have been estimated based on data from animal tissue measurements [23].”
Thermal dose determination in cancer therapy
Sapareto, S. A., & Dewey, W. C. (1984) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(84)90379-1 · Cited by 2,498 · cited 1×
“Because tissue damage not only depends on the tissue temperature increase but also on the exposure time, the transient temperature increases are translated into an effective thermal load by applying the thermal dose model of cumulative equivalent minutes at 43 °C (CEM43) [128].”
GUIDELINES FOR LIMITING EXPOSURE TO TIME-VARYING ELECTRIC AND MAGNETIC FIELDS (1 Hz TO 100 kHz)
(2010) · Health Physics · doi:10.1097/hp.0b013e3181f06c86 · Cited by 2,164 · cited 5×
“This leakage in the neighborhood environment has increased the need to determine compliance of WPT systems with the EMC and safety standards [1], [2], [33].”
InfluentialGuidelines for Limiting Exposure to Electromagnetic Fields (100 kHz to 300 GHz)
(2020) · Health Physics · doi:10.1097/hp.0000000000001210 · Cited by 2,081 · cited 1×
“International Commission on Non-Ionizing Radiation Protection (ICNIRP), set safety guidelines/standards to protect people from excessive exposure to EMF [1-3].”
Christ, A., Kainz, W., Hahn, E. G., Honegger, K., Zefferer, M., Neufeld, E., Rascher, W., Janka, R., Bautz, W., Chen, J., et al. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/2/n01 · Cited by 1,439
Self-citationLin, J., Saunders, R. A., Schulmeister, K., Söderberg, P. G., Stuck, B. E., Swerdlow, A. J., Taki, M., Veyret, B., Ziegelberger, G., Repacholi, M. H., et al. (2010) · HAL · Cited by 1,261
Computerized three‐dimensional segmented human anatomy
Zubal, I. G., Harrell, C. R., Smith, E. O., Rattner, Z., Gindi, G., & Hoffer, P. B. (1994) · Medical Physics · doi:10.1118/1.597290 · Cited by 1,103 · cited 1×
“Earlier attempts for anthropomorphic human models, as in [8] consisted of 36 organs/tissues in 1 mm image resolution; however, the longitudinal resolution was low at 5–10 mm.”
Nagaoka, T., Watanabe, S., Sakurai, K., Kunieda, E., Watanabe, S., Taki, M., & Yamanaka, Y. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/1/001 · Cited by 774
Thresholds for thermal damage to normal tissues: An update
Yarmolenko, P. S., Moon, E. J., Landon, C., Manzoor, A., Hochman, D. W., Viglianti, B. L., & Dewhirst, M. W. (2011) · International Journal of Hyperthermia · doi:10.3109/02656736.2010.534527 · Cited by 754 · cited 1×
“To prevent potential tissue damage, maximum tolerable CEM43 values and maximum allowed scan times have been established for various tissues [129].”
Electrical conductivity of tissue at frequencies below 1 MHz
Gabriel, C., Peyman, A., & Grant, E. H. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/16/002 · Cited by 716 · cited 1×
“Therefore, knowledge of dielectric properties in this frequency range is limited [30, 32].”
FastSurfer - A fast and accurate deep learning based neuroimaging pipeline
Henschel, L., Conjeti, S., Estrada, S., Diers, K., Fischl, B., & Reuter, M. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117012 · Cited by 660 · cited 1×
“In particular, it has become possible to generate reliable, high quality segmentation in a short time which is close to expert manual segmentation [21, 22].”
Coil Design and Shielding Methods for a Magnetic Resonant Wireless Power Transfer System
Kim, J., Kim, J. J., Kong, S., Kim, H., Suh, I.-S., Suh, N. P., Cho, D., Kim, J., & Ahn, S. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2013.2247551 · Cited by 505
Self-citationIn vivo study of human skin using pulsed terahertz radiation
Pickwell, E., Cole, B. E., Fitzgerald, A. J., Pepper, M., & Wallace, V. P. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/9/001 · Cited by 381 · cited 1×
“At frequencies higher than 6 GHz, the dielectric properties of tissues comprising the skin [28, 29] and eyes have been measured [30].”
O’Rourke, A. P., Lazebnik, M., Bertram, J. M., Converse, M., Hagness, S. C., Webster, J. G., & Mahvi, D. M. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/15/022 · Cited by 343 · cited 1×
“The variations in tissue dielectric properties by species (human and animal) [24, 25] and postmortem effects ( in vivo and in vitro ) [24, 26], from 100 MHz to 10 GHz, have been investigated.”
Bailey, W. H., Harrington, T., Hirata, A., Kavet, R. R., Keshvari, J., Klauenberg, B. J., Legros, A., Maxson, D. P., Osepchuk, J. M., Reilly, J. P., et al. (2019) · IEEE Access · doi:10.1109/access.2019.2954823 · Cited by 251 · cited 9×
“1 [1], coherent non-sinusoidal waveforms can be considered by determining their frequency from the phase durations of the waveform.”
InfluentialSelf-citationWireless Power Transfer for Light-Duty Plug-in/Electric Vehicles and Alignment Methodology
Hybrid - EV Committee (2020) · doi:10.4271/j2954_202010 · Cited by 248
Design and Analysis of a Resonant Reactive Shield for a Wireless Power Electric Vehicle
Kim, S., Park, H.-H., Kim, J., Kim, J., & Ahn, S. (2014) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2014.2305404 · Cited by 247 · cited 1×
“A resonant reactive shielding method to compensate for the disadvantage of active shielding, such as requirement of additional current source and difficulty in synchronization between source and cancelling fields, has been presented [106].”
Self-citationMEDICAL MAGNETIC RESONANCE (MR) PROCEDURES: PROTECTION OF PATIENTS
(2004) · Health Physics · doi:10.1097/00004032-200408000-00008 · Cited by 243 · cited 1×
“Additionally, the ICNIRP published three statements pertaining to the protection of patients during MR procedures [118]–[120].”
Handbook of Anatomical Models for Radiation Dosimetry
(2009) · CRC Press eBooks · doi:10.1201/ebk1420059793 · Cited by 225
Zaidi, H., & Xu, X. G. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151934 · Cited by 219 · cited 1×
“With a long history starting with simple geometric representations [6], human models have reached an advanced quality representing human anatomy with superior accuracy (e.g., [7]).”
Human skin permittivity determined by millimeter wave reflection measurements
Alekseev, S. I., & Ziskin, M. C. (2007) · Bioelectromagnetics · doi:10.1002/bem.20308 · Cited by 194 · cited 2×
“Variations in the dielectric properties of skin at each body part have also been reported owing to the variation in the thickness of the stratum corneum and the underlying tissues [29].”
Generalized Active EMF Cancel Methods for Wireless Electric Vehicles
Choi, S. Y., Gu, B. W., Lee, S. W., Lee, W. Y., Huh, J., & Rim, C. T. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2295094 · Cited by 184 · cited 1×
“Different groups proposed active shielding to reduce the magnetic field leakage by field cancelation [104, 105].”
Conil, E., Hadjem, A., Lacroux, F., Wong, M. F., & Wiart, J. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/6/001 · Cited by 172 · cited 1×
“Several studies have also developed infants and children models (e.g., [17]).”
Emerging Technologies [wireless communication systems for implantable medical devices]
Panescu, D. (2008) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/emb.2008.915488 · Cited by 163 · cited 1×
“In general, the transmitting power for an in-body wireless devices (such as medical implant communication system) and wearable communications are low [66, 67].”
Chakeres, D. W., Kangarlu, A., Boudoulas, H., & Young, D. C. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10367 · Cited by 161 · cited 2×
“However, no clinically significant effects on heart rate, respiratory rate, systolic and diastolic blood pressure, finger pulse oxygenation levels, or core body temperature of healthy volunteers, during and after exposure to an 8T static magnetic field, were found [123].”
Dimbylow, P. J. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/2/001 · Cited by 156 · cited 1×
“Later, the same number of organs was presented at a unified 2 mm resolution [9].”
Röösli, M., Frei, P., Bolte, J. F. B., Neubauer, G., Cardis, E., Feychting, M., Gajšek, P., Heinrich, S., Joseph, W., Mann, S., et al. (2010) · Environmental Health · doi:10.1186/1476-069x-9-23 · Cited by 141
A Technique to Evaluate MRI-Induced Electric Fields at the Ends of Practical Implanted Lead
Feng, S., Qiang, R., Kainz, W., & Chen, J. (2014) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2014.2376523 · Cited by 140 · cited 1×
“PIMD and AIMD tests are performed experimentally, computationally, or a combination thereof [133].”
Self-citationHigh-resolution organ dosimetry for human exposure to low-frequency magnetic fields
Dawson, T. W., & Stuchly, M. A. (1998) · IEEE Transactions on Magnetics · doi:10.1109/20.668071 · Cited by 140 · cited 1×
“The most commonly used computational methods at LF are the scalar-potential finite-difference method [34] and the finite-element method (FEM) [35].”
Monte Carlo simulations of skin exposure to electromagnetic field from 10 GHz to 1 THz
Sasaki, K., Mizuno, M., Wake, K., & Watanabe, S. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa81fc · Cited by 137 · cited 2×
“This is also valid for frequencies from 10 GHz to 1 THz where the transmittance is slightly affected by variations in the tissue dielectric properties [52].”
Self-citationPeyman, A., Holden, S. J., Watts, S. A., Perrott, R., & Gabriel, C. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/8/013 · Cited by 128 · cited 3×
“Studies reported that the dielectric properties of mammalian tissue well represent those of humans [24].”
Reducing the staircasing error in computational dosimetry of low-frequency electromagnetic fields
Laakso, I., & Hirata, A. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/4/n25 · Cited by 122 · cited 1×
“In the case of localized exposure, the 99 th percentile can underestimate the maximum induced electric field [37].”
Self-citationNagaoka, T., Togashi, T., Saito, K., Takahashi, M., Ito, K., & Watanabe, S. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/22/012 · Cited by 120 · cited 1×
“Special models that represent pregnant women have been constructed in [15, 16].”
Tissue models for RF exposure evaluation at frequencies above 6 GHz
Ziskin, M. C., Alekseev, S. I., Foster, K. R., & Balzano, Q. (2018) · Bioelectromagnetics · doi:10.1002/bem.22110 · Cited by 115 · cited 2×
“At higher frequencies, the increase in skin temperature strongly depends on tissue thickness and the heat transfer coefficient between the skin and the environment [51, 52, 62].”
Principles for Non-Ionizing Radiation Protection
International Commission on Non-Ionizing Radiation Protection (2020) · Health Physics · doi:10.1097/hp.0000000000001252 · Cited by 114 · cited 4×
“This leakage in the neighborhood environment has increased the need to determine compliance of WPT systems with the EMC and safety standards [1], [2], [33].”
InfluentialKainz, W., Neufeld, E., Bolch, W. E., Graff, C. G., Kim, C. H., Kuster, N., Lloyd, B., Morrison, T., Segars, P., Yeom, Y. S., et al. (2019) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2018.2883437 · Cited by 109 · cited 1×
“Human models play a vital role in characterizing and analyzing several physical and biological effects in the research area related to EMC; such as human protection, product safety, and biomedical sciences [5].”
Self-citationChen, X. L., Umenei, A. E., Baarman, D., Chavannes, N., Santis, V. D., Mosig, J. R., & Kuster, N. (2014) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.2014.2308013 · Cited by 104 · cited 1×
“Close-range or low-power portable devices have been evaluated for different types of systems and coupling mechanisms: induction coupling in the kHz range [96] and resonant coupling in the MHz range [97].”
Kim, C. H., Choi, S. H., Jeong, J. H., Lee, C., & Chung, M. S. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/15/006 · Cited by 100
Nagaoka, T., Kunieda, E., & Watanabe, S. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/23/004 · Cited by 94 · cited 1×
“more reliable application-based models, as shown in [18, 19].”
Massey, J. W., & Yılmaz, A. E. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591444 · Cited by 93
On the averaging area for incident power density for human exposure limits at frequencies over 6 GHz
Hashimoto, Y., Hirata, A., Morimoto, R., Aonuma, S., Laakso, I., Jokela, K., & Foster, K. R. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa5f21 · Cited by 91 · cited 1×
“Above 6 GHz, the international guidelines introduced the absorbed/ epithelial power density averaged over 4 cm 2 as a surrogate for skin temperature rise [47].”
Self-citationConductivities of epidermis, dermis, and subcutaneous tissue at intermediate frequencies
Wake, K., Sasaki, K., & Watanabe, S. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/12/4376 · Cited by 90 · cited 2×
“Recent studies suggest that the conductivity of skin and brain tissues may be significantly higher than those commonly used in LF dosimetry (e.g., [31]).”
Self-citationAdda, S., Aureli, T., D’Elia, S., Franci, D., Grillo, E., Migliore, M. D., Pavoncello, S., Schettino, F., & Suman, R. (2020) · IEEE Access · doi:10.1109/access.2020.2998448 · Cited by 87 · cited 1×
“Extrapolation techniques, as described in IEC 62232, are to be used (e.g., [83-85]) when the objective of the measurements is to evaluate the maximum exposure at a location on site.”
Emerging medical applications based on non-ionizing electromagnetic fields from 0 Hz to 10 THz
Mattsson, M., & Simkó, M. (2019) · Medical Devices Evidence and Research · doi:10.2147/mder.s214152 · Cited by 86 · cited 10×
“breast imaging used as a complimentary tool to mammography), and MRI [113].”
InfluentialHirata, A., & Fujiwara, O. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/23/013 · Cited by 85 · cited 1×
“At frequencies below 6 GHz, peak spatial-SAR cubically averaged over 10 g of tissue is an approximate surrogate of local temperature rise [46].”
Self-citationReilly, J. P., & Hirata, A. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/12/r138 · Cited by 83 · cited 1×
“III) are summarized by various international standardization bodies [4, 138, 139].”
Self-citationBolte, J. F. B. (2016) · Environment International · doi:10.1016/j.envint.2016.06.023 · Cited by 80 · cited 1×
“This lack of on-body calibration combined with body shadowing and cross-talk can cause uncertainties up to 30 dB [91].”
Brockow, T., Wagner, A., Franke, A., Offenbächer, M., & Resch, K. L. (2006) · Clinical Journal of Pain · doi:10.1097/ajp.0b013e31802b4f80 · Cited by 79 · cited 1×
“1 [1] limits the whole-body average SAR up to 6 GHz, the ICNIRP guidelines [33] provides limits for the whole-body averaged SAR up to 300 GHz. which is based on the study of [48], revealing that infrared radiation can increase the body core temperature.”
Yeom, Y. S., Jeong, J. H., Kim, C. H., Han, M. C., Ham, B. K., Cho, K. W., & Hwang, S. B. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/14/3969 · Cited by 79
Li, K., Sasaki, K., Watanabe, S., & Shirai, H. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab057a · Cited by 75 · cited 3×
“The transmittance of the TM (transverse magnetic) wave into the skin increases with the angle of incidence up to the maximum transmittance angle [53, 54] because of Brewster's angle effect.”
Self-citationPrinciples of Nerve and Heart Excitation by Time‐varying Magnetic Fields
REILLY, J. P. (1992) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1992.tb49600.x · Cited by 70 · cited 1×
“For very long gradient EMF pulses, the peripheral nerve stimulation threshold is ~19 T/s [126], whereas the cardiac stimulation threshold is ~ 400 T/s [127].”
Bakker, J. F., Paulides, M. M., Neufeld, E., Christ, A., Chen, X. L., Kuster, N., & van Rhoon, G. C. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/7/1815 · Cited by 64 · cited 1×
“Although limitations have previously been identified in the averaging method of ICNIRP (e.g., [43]), a recent study showed that both averaging methods produce comparable and conservative estimates of the electric field [44].”
Kanezaki, A., Hirata, A., Watanabe, S., & Shirai, H. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/16/003 · Cited by 63 · cited 1×
“At higher frequencies, the increase in skin temperature strongly depends on tissue thickness and the heat transfer coefficient between the skin and the environment [51, 52, 62].”
Self-citationShimamoto, T., Laakso, I., & Hirata, A. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/1/163 · Cited by 61 · cited 1×
“than the remaining body parts for larger coils [100].”
Self-citationHuman exposure to pulsed fields in the frequency range from 6 to 100 GHz
Laakso, I., Morimoto, R., Heinonen, J., Jokela, K., & Hirata, A. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa81fe · Cited by 60 · cited 1×
“Several studies investigated the temperature rise from brief exposures to EMF [55, 56].”
Self-citationMorimoto, R., Hirata, A., Laakso, I., Ziskin, M. C., & Foster, K. R. (2017) · Physics in Medicine and Biology · doi:10.1088/1361-6560/aa5251 · Cited by 57 · cited 1×
“In addition, the temperature distribution is smooth because of the heat diffusion and is thus insensitive to numerical uncertainties [59].”
Self-citationSchmid, G., Cecil, S., & Überbacher, R. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/13/4703 · Cited by 56 · cited 1×
“For instance, the conductivity value of the skin can have a large impact on the estimation of the induced electric field [41].”
Skin Temperature Elevation for Incident Power Densities From Dipole Arrays at 28 Ghz
Nakae, T., Funahashi, D., Higashiyama, J., Onishi, T., & Hirata, A. (2020) · IEEE Access · doi:10.1109/access.2020.2970219 · Cited by 52 · cited 1×
“The transmittance of the TM (transverse magnetic) wave into the skin increases with the angle of incidence up to the maximum transmittance angle [53, 54] because of Brewster's angle effect.”
Self-citationForeign Object Detection for Electric Vehicle Wireless Charging
Xia, J., Yuan, X., Li, J., Lu, S., Cui, X., Li, S., & RAMIREZ, L. M. F. (2020) · Electronics · doi:10.3390/electronics9050805 · Cited by 51 · cited 1×
“This object detection system prevents heating of metallic objects in the vicinity of the WPT system and reduces possible interference with active implantable medical devices [111, 112].”
Arduino, A., Bottauscio, O., Chiampi, M., Giaccone, L., Liorni, I., Kuster, N., Zilberti, L., & Zucca, M. (2020) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.2019.2954111 · Cited by 51 · cited 1×
“Recently, a proposed statistically based approach removed the underestimation caused by percentile filtering [39, 40].”
Self-citationSantis, V. D., Campi, T., Cruciani, S., Laakso, I., & Feliziani, M. (2018) · Energies · doi:10.3390/en11030684 · Cited by 50
Self-citationPre- and post-natal exposure of children to EMF generated by domestic induction cookers
Kos, B., Valič, B., Miklavčič, D., Kotnik, T., & Gajšek, P. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/19/001 · Cited by 48
International Commission on Non-Ionizing Radiation Protection (ICNIRP) (2017) · Health Physics · doi:10.1097/hp.0000000000000654 · Cited by 47
Schmid, G., & Überbacher, R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/19/019 · Cited by 45 · cited 1×
“In addition, the effects of aging on the dielectric properties of tissues were investigated [24, 27], allowing the dielectric data to reflect variations in age for numerical human models.”
Survey of numerical electrostimulation models
Reilly, J. P. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/12/4346 · Cited by 45 · cited 1×
“The above-mentioned limits are settled based on the field strength in a conservative manner without considering the nerve stimulation, in which detailed multiscale (nerve activation) simulation is needed [45].”
Shah, I. A., Cho, Y., & Yoo, H. (2020) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.2020.3023734 · Cited by 45 · cited 1×
“Other studies of importance are those on the charging of a dynamic WPT system (e.g., [101]) and safety issues related to passengers with medical implants, particularly active implantable medical devices [102].”
Foster, K. R., Ziskin, M. C., Balzano, Q., & Bit-Babik, G. (2018) · Health Physics · doi:10.1097/hp.0000000000000854 · Cited by 40 · cited 1×
“The heating factor, or the ratio of the peak temperature rise to the peak value of SAR averaged over 10 g tissue, was observed to be lower than 0.25 °C/(W/kg) in the skin and 0.1 °C/(W/kg) in the brain after 30 min of exposure [50].”
InfluentialWerner, R., Knipe, P., & Iskra, S. (2019) · IEEE Access · doi:10.1109/access.2019.2955715 · Cited by 39 · cited 1×
“Recently, several numerical and experimental studies determined the actual maximum power level contributing to EMF exposure for base stations implementing beamforming (e.g., [79-82]).”
Campi, T., Cruciani, S., Maradei, F., Montalto, A., Musumeci, F., & Feliziani, M. (2021) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.2020.3047465 · Cited by 38 · cited 1×
“As the number of medical electronic devices increase, the reduction of the magnetic field on implantable medical devices has also been suggested in [109].”
Rashed, E. A., Gomez-Tames, J. D., & Hirata, A. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116132 · Cited by 35 · cited 1×
“In particular, it has become possible to generate reliable, high quality segmentation in a short time which is close to expert manual segmentation [21, 22].”
Self-citationSunohara, T., Hirata, A., Laakso, I., & Onishi, T. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/14/3721 · Cited by 34 · cited 1×
“Close-range or low-power portable devices have been evaluated for different types of systems and coupling mechanisms: induction coupling in the kHz range [96] and resonant coupling in the MHz range [97].”
Self-citationCompliance Boundaries of 5G Massive MIMO Radio Base Stations: A Statistical Approach
Pinchera, D., Migliore, M. D., & Schettino, F. (2020) · IEEE Access · doi:10.1109/access.2020.3028471 · Cited by 34
Laakso, I., Ilvonen, S., & Uusitupa, T. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/23/027 · Cited by 33 · cited 1×
“Computational errors resulting from the staircasing and simulation settings such as spatial resolution, source modeling, boundary condition, and stop criterion, are common uncertainties associated with RF dosimetry using the FDTD method, but can be reduced by proper implementation and using more computational resource…”
Self-citationElectromagnetic Dosimetry and Compliance for Wireless Power Transfer Systems in Vehicles
Miwa, K., Takenaka, T., & Hirata, A. (2019) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.2019.2949983 · Cited by 33 · cited 1×
“Several studies addressed human exposure to WPT systems in EVs for different human postures and chassis materials (e.g., [98, 99]).”
Self-citationShikhantsov, S., Thielens, A., Aerts, S., Verloock, L., Torfs, G., Martens, L., Demeester, P., & Joseph, W. (2020) · Applied Sciences · doi:10.3390/app10217631 · Cited by 31
Rashed, E. A., Diao, Y., & Hirata, A. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab7308 · Cited by 28 · cited 1×
“Recent publications reported a novel approach for dielectric measurements that allows the estimation of dielectric human tissue properties in vivo using MRI [137].”
Self-citationKyriakou, A., Neufeld, E., Szczerba, D., Kainz, W., Luechinger, R., Kozerke, S., McGregor, R., & Kuster, N. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/2/117 · Cited by 26
Self-citationZeng, Q. Y., Liu, J., Angelone, L. M., Lloyd, T. D. R., Wedan, S., Chen, J., & Kainz, W. (2018) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.2018.2862249 · Cited by 24 · cited 1×
“AIMD leads, which can result in a 20-fold increase in RF EMFinduced heating [134-136].”
Self-citationElectromagnetic Field Assessment as a Smart City Service: The SmartSantander Use-Case
Diez, L. F., Agüero, R., & Muñoz, L. (2017) · Sensors · doi:10.3390/s17061250 · Cited by 18 · cited 1×
“It also enables the creation of spatial maps of EMFs in real environments [92] and monitors the temporal behavior of the fields over periods spanning multiple years [89, 93].”
Soldati, M., & Laakso, I. (2020) · IEEE Access · doi:10.1109/access.2020.3043602 · Cited by 18
Self-citationYao, A., Goren, T., Samaras, T., Kuster, N., & Kainz, W. (2021) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28836 · Cited by 17 · cited 1×
“safety of broken and abandoned AIMD leads, which can result in a 20-fold increase in RF EMF-induced heating [134]–[136].”
Self-citationGomez-Tames, J. D., Tarnaud, T., Miwa, K., Hirata, A., de Steene, T. V., Martens, L., Tanghe, E., & Joseph, W. (2019) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.2019.2943138 · Cited by 16 · cited 1×
“The topics listed therein relate to human body modeling, as well as the necessity of more accurate dosimetry, which includes reductions of uncertainties, and multi-physics or multi-scale methods for correlating the field quantities with substantiated biological effects (e.g., [140]).”
Self-citationElectromagnetic Model-Based Foreign Object Detection for Wireless Power Transfer
Chu, S. Y., & Avestruz, A.-T. (2019) · IEEE ... Workshop on Control and Modeling for Power Electronics · doi:10.1109/compel.2019.8769626 · Cited by 14 · cited 1×
“This object detection system prevents heating of metallic objects in the vicinity of the WPT system and reduces possible interference with active implantable medical devices [111, 112].”
Development and validation of a magneto-hydrodynamic solver for blood flow analysis
Kainz, W., Guag, J. W., Benkler, S., Szczerba, D., Neufeld, E., Krauthamer, V., Myklebust, J. B., Bassen, H., Chang, I. A., Chavannes, N., et al. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/23/005 · Cited by 14 · cited 1×
“Strong magnetic fields exert electrodynamic forces on moving ions in the blood vessels [121] of stationary”
Self-citationICNIRP Statement on Diagnostic Devices Using Non-Ionizing Radiation
Kromhout, H., Slottje, P., Huss, A., van Nierop, L. E., Bongers, S., Schaap, K., & de Vocht, F. (2017) · Health Physics · doi:10.1097/hp.0000000000000686 · Cited by 9 · cited 1×
“Additionally, the ICNIRP published three statements pertaining to the protection of patients during MR procedures [118]–[120].”
Metadata
- Authors
- Hirata, A., Diao, Y., Onishi, T., Sasaki, K., Ahn, S., Colombi, D., De Santis, V., Laakso, I., Giaccone, L., Wout, J., Rashed, E., Kainz, W., & Chen, J.
- Venue
- IEEE Transactions on Electromagnetic Compatibility
- Published
- 2021-10
- Volume
- 63
- Issue
- 5
- Pages
- 1619-1630
- ISSN
- 0018-9375 (ISSN-L)
- 1558-187X
- OpenAlex
- W3202198480
- Cited by
- 161
- References
- 87
- FWCI
- 11.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.