Report of Large Motor Reliability Survey of Industrial and Commercial Installations, Part I
The DOI matches its Crossref record.
Abstract
The Power Systems Reliability Subcommittee of the IEEE Industry Applications Society recently initiated a survey of the reliability of large motors in industrial and commercial installations in keeping with its commitment to support or update results of the survey published in 1973 and 1974. Moreover, the new survey has emphasized and expanded on one type of electrical equipment only. The previous survey results were heavily biased by one class of motors in the motor category and contained some results that appeared unreasonable and were considered questionable. The results of this new survey are presented here and intended to expand failure data to additional influencing categories and at the same time be oriented to the more common types in use today. A restriction to a lower limit in size also distinguishes the results to motors in relatively critical applications. A further explanation of the reasons for this survey and intended results is presented in a subcommittee report included for reference in the Appendix.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A review of induction motors signature analysis as a medium for faults detection
El Hachemi Benbouzid, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873206 · Cited by 1,602
Current Signature Analysis to Detect Induction Motor Faults
Thomson, W. T., & Fenger, M. (2001) · IEEE Industry Applications Magazine · doi:10.1109/2943.930988 · Cited by 1,139
Deep Learning Algorithms for Bearing Fault Diagnostics—A Comprehensive Review
Zhang, S., Zhang, S., Wang, B., & Habetler, T. G. (2020) · IEEE Access · doi:10.1109/access.2020.2972859 · Cited by 913
Motor bearing damage detection using stator current monitoring
Schoen, R. R., Habetler, T. G., Kamran, F., & Bartfield, R. G. (1995) · IEEE Transactions on Industry Applications · doi:10.1109/28.475697 · Cited by 761
A Survey of Condition Monitoring and Protection Methods for Medium-Voltage Induction Motors
Zhang, P., Du, Y., Habetler, T. G., & Lu, B. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2010.2090839 · Cited by 706
Motor bearing damage detection using stator current monitoring
Schoen, R. R., Habetler, T. G., Kamran, F., & Bartheld, R. G. (2002) · Proceedings of 1994 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1994.345491 · Cited by 638
A Review of Stator Fault Monitoring Techniques of Induction Motors
Siddique, A., Yadava, G. S., & Singh, B. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.837304 · Cited by 591
Models for Bearing Damage Detection in Induction Motors Using Stator Current Monitoring
Blodt, M., Granjon, P., Raison, B., & Rostaing, G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.917108 · Cited by 568
Neupane, D., & Seok, J. (2020) · IEEE Access · doi:10.1109/access.2020.2990528 · Cited by 568
A survey of condition monitoring and protection methods for medium voltage induction motors
Zhang, P., Du, Y., Habetler, T. G., & Lu, B. (2009) · 2009 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2009.5316083 · Cited by 524
Grubic, S., Aller, J. M., Lu, B., & Habetler, T. G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2004665 · Cited by 490
The detection of inter-turn short circuits in the stator windings of operating motors
Joksimovic, G. M., & Penman, J. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873216 · Cited by 471
Immovilli, F., Bellini, A., Rubini, R., & Tassoni, C. (2010) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2010.2049623 · Cited by 382
Benbouzid, M. E. H., Vieira, M., & Theys, C. (1999) · IEEE Transactions on Power Electronics · doi:10.1109/63.737588 · Cited by 378
Thorsen, O. V., & Dalva, M. (1995) · IEEE Transactions on Industry Applications · doi:10.1109/28.464536 · Cited by 344
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
A Survey of Methods for Detection of Stator-Related Faults in Induction Machines
Tallam, R. M., Lee, S. B., Stone, G. C., Kliman, G. B., Yoo, J., Habetler, T. G., & Harley, R. G. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.900448 · Cited by 301
Leite, V. C. M. N., Borges da Silva, J. G., Veloso, G. F. C., Borges da Silva, L. E., Lambert-Torres, G., Bonaldi, E. L., & de Lacerda de Oliveira, L. E. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2345330 · Cited by 274
Thorsen, O. V., & Dalva, M. (2002) · Proceedings of IEEE Petroleum and Chemical Industry Technical Conference (PCIC '94) · doi:10.1109/pcicon.1994.347637 · Cited by 264
Frosini, L., & Bassi, E. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2026770 · Cited by 254
Drif, M., & Cardoso, A. J. M. (2014) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2014.2307013 · Cited by 235
“The latter is considered as the most severe one, which can cause substantial and irreversible damage to the stator winding and core [1]–[12].”
BackgroundInfluentialFailure identification and analysis for high-voltage induction motors in the petrochemical industry
Thorsen, O. V., & Dalva, M. (1999) · IEEE Transactions on Industry Applications · doi:10.1109/28.777188 · Cited by 228
Vibration Spectrum Imaging: A Novel Bearing Fault Classification Approach
Amar, M., Gondal, I., & Wilson, C. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2327555 · Cited by 222
“Majority of the faults in the motors (about 41% of the total faults) are due to bearings [1].”
BackgroundSeera, M., Lim, C. P., Ishak, D., & Singh, H. (2012) · IEEE Transactions on Neural Networks and Learning Systems · doi:10.1109/tnnls.2011.2178443 · Cited by 185
An industry-based survey of reliability in power electronic converters
Yang, S., Bryant, A., Mawby, P., Xiang, D., Ran, L., & Tavner, P. (2009) · 2009 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2009.5316356 · Cited by 160
Statistical Spectral Analysis for Fault Diagnosis of Rotating Machines
Ciabattoni, L., Ferracuti, F., Freddi, A., & Monteriu, A. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2762623 · Cited by 160
Da, Y., Shi, X., & Krishnamurthy, M. (2011) · 2011 IEEE Vehicle Power and Propulsion Conference · doi:10.1109/vppc.2011.6043248 · Cited by 96
Wang, B., Wang, J., Griffo, A., & Huang, L. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2019.2908595 · Cited by 33
Effect of Magnets Asymmetry on Stray Magnetic Flux Based Bearing Damage Detection in PMSM
Gurusamy, V., Baruti, K. H., Zafarani, M., Lee, W., & Akin, B. (2021) · IEEE Access · doi:10.1109/access.2021.3076779 · Cited by 28
Bearing damage diagnosis by means of the linear discriminant analysis of stator current feature
Mbo'o, C. P., & Hameyer, K. (2015) · 2015 IEEE 10th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) · doi:10.1109/demped.2015.7303705 · Cited by 11
Metadata
- Venue
- IEEE Transactions on Industry Applications
- Published
- 1985
- Volume
- IA-21
- Issue
- 4
- Pages
- 853-864
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W4253290211
- Cited by
- 602
- References
- 0
- FWCI
- 10.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.