A New Approach to Improve Power factor and Reduce Harmonicsin a Three-Phase Diod Rectifier Type Utility Interface
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
this paper, a new approach to improve power factor and reduce harmonics generated by a three-phase diode rectifier type utility interface is proposed. The proposed approach is passive and consists of a novel interconnection of a star / delta transformer between the ac and dc sides of the diode rectifier topology (see Fig. 1). This novel interconnection, in combination with the 120° conduction intervals of each diode, is shown to generate a circulating third harmonic current between the ac and dc side of the rectifier bridge. The circulating third harmonic current between the ac and dc side of the rectifier bridge. The circulating third harmonic current is then shown to drastically improve the performance of the diode rectifier type interface. The resulting input current is near sinusoidal in shape with significant reduction in line current harmonics. The proposed system can be viewed as a cost-effective retrofit to the existing diode rectifier utility interface applications. Analysis and design of the proposed approach are examined in per-unit quantities. A suitable design example illustrates the sizing of the necessary passive components. Selected results are verified experimentally on a laboratory prototype system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rashid, R. (1988) · Cited by 2,662
Analysis of Faulted Power Systems
Anderson, P. M. (2009) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470544129 · Cited by 586
Analysis of faulted power systems,
Magnusson, P. C. (1974) · Journal of the Franklin Institute · doi:10.1016/0016-0032(74)90099-4 · Cited by 411
Harmonic reduction in multiplex convertors by triple-frequency current injection
Bird, B. M., Marsh, J. F., & McLellan, P. R. (1969) · Proceedings of the Institution of Electrical Engineers · doi:10.1049/piee.1969.0316 · Cited by 169
Duffey, C. K., & Stratford, R. P. (2003) · Record of conference papers/Record of conference papers - Petroleum and Chemical Industry Conference · doi:10.1109/pcicon.1988.22445 · Cited by 76
Rastogi, M., Naik, R., & Mohan, N. (2003) · PESC record · doi:10.1109/pesc.1992.254707 · Cited by 29
Increasing the Pulse Number of AC-DC Convertors by Current Reinjection Techniques
Arrillaga, J., Joosten, A. P. B., & Baird, J. F. (1983) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1983.317669 · Cited by 29
Cited by
A Review of Three-Phase Improved Power Quality AC–DC Converters
Singh, B., Singh, B. N., Chandra, A., Al-Haddad, K., Pandey, A., & Kothari, D. P. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.825341 · Cited by 1,728
The Essence of Three-Phase PFC Rectifier Systems—Part I
Kolar, J. W., & Friedli, T. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2197867 · Cited by 788
Multipulse AC–DC Converters for Improving Power Quality: A Review
Singh, B., Gairola, S., Singh, B. N., Chandra, A., & Al-Haddad, K. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.911880 · Cited by 412
Choi, S., Enjeti, P. N., & Pitel, I. J. (1996) · IEEE Transactions on Power Electronics · doi:10.1109/63.535400 · Cited by 177
Self-citationThe essence of three-phase PFC rectifier systems
Kolar, J. W., & Friedli, T. (2011) · 2011 IEEE 33rd International Telecommunications Energy Conference (INTELEC) · doi:10.1109/intlec.2011.6099838 · Cited by 172
Metadata
- Authors
- Kim, S., Enjeti, P. N., & Pitel, I. J.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 1994-11
- Volume
- 30
- Issue
- 6
- Pages
- 1557
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2167750311
- Cited by
- 173
- References
- 7
- FWCI
- 8.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.