A frequency-domain detection of stator winding faults in induction machines using an external flux sensor
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The aim of this paper is to present the advantage of stator fault detection using an external stray flux sensor in a working induction machine. In the past 20 years, stray flux sensors have been used for diagnostic purposes but rarely in the presence of a complex power supply such as a voltage static inverter. In this paper, it is proved that a simple external stray flux sensor is more efficient than the classical stator current signature analysis to detect inter-turn short circuit in three-phase induction machines. The new result is that, even in the presence of power supply harmonics, it is possible to easily detect the stator winding faults in the low-frequency range of the flux spectrum with low-frequency resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Detection and location of interturn short circuits in the stator windings of operating motors
Penman, J., Sedding, H. G., Lloyd, B. A., & Fink, W. T. (1994) · IEEE Transactions on Energy Conversion · doi:10.1109/60.368345 · Cited by 394
Condition monitoring of electrical machines
Tavner, P., & Penman, J. (1987) · Durham Research Online (Durham University) · Cited by 353
Induction machine condition monitoring with higher order spectra
Arthur, N., & Penman, J. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873211 · Cited by 170
Condition monitoring of electrical drives
Penman, J., Dey, M. N., Tait, A. J., & Bryan, W. E. (1986) · IEE Proceedings B Electric Power Applications · doi:10.1049/ip-b.1986.0019 · Cited by 127
Cited by
Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382
Advances in Diagnostic Techniques for Induction Machines
Bellini, A., Filippetti, F., Tassoni, C., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007527 · Cited by 1,140
“fully applied to monitor machine conditions [63], [64] provided that a suitable shield was available to prevent the influence of”
MethodSelf-citationGangsar, P., & Tiwari, R. (2020) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2020.106908 · Cited by 605
Trends in Fault Diagnosis for Electrical Machines: A Review of Diagnostic Techniques
Henao, H., Capolino, G.-A., Fernandez-Cabanas, M., Filippetti, F., Bruzzese, C., Strangas, E., Pusca, R., Estima, J., Riera-Guasp, M., & Hedayati-Kia, S. (2014) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2287651 · Cited by 602
Self-citationRecent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544
Review of condition monitoring of rotating electrical machines
Tavner, P. J. (2008) · IET Electric Power Applications · doi:10.1049/iet-epa:20070280 · Cited by 531
A High-Resolution Frequency Estimation Method for Three-Phase Induction Machine Fault Detection
Kia, S. H., Henao, H., & Capolino, G.-A. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.899826 · Cited by 325
Self-citationModeling of Surface-Mounted Permanent Magnet Synchronous Motors With Stator Winding Interturn Faults
Romeral, L., Urresty, J. C., Riba Ruiz, J.-R., & Garcia Espinosa, A. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2062480 · Cited by 282
Frosini, L., Harlisca, C., & Szabo, L. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2361115 · Cited by 264
Drif, M., & Cardoso, A. J. M. (2014) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2014.2307013 · Cited by 235
“A substantial amount of research has been conducted in the last decades to diagnose stator winding faults in inductionmotordrive systems [5]–[45], such as those based on the analysis of vibration [14], axial leakage flux [15], [16], and stray flux [17].”
BackgroundSarikhani, A., & Mohammed, O. A. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2222857 · Cited by 177
“However, redundancy in fault detection systems by adding search coil, [21], the need for additional measurement system [22], underestimation of fault and nonsinusoidal armature flux linkage harmonics as well as the adverse effect of unbalance in the supply voltage [23], underestimation of non-stationary behavior of fa…”
BackgroundHigh Frequency Resolution Techniques for Rotor Fault Detection of Induction Machines
Bellini, A., Yazidi, A., Filippetti, F., Rossi, C., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007004 · Cited by 163
“In the literature, many other spectral estimation techniques have been presented to cope with these drawbacks [6]–[9].”
BackgroundSelf-citationGurusamy, V., Bostanci, E., Li, C., Qi, Y., & Akin, B. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.3013128 · Cited by 93
“It has been observed in [16] that the stray flux has a high signal to noise ratio and good sensitivity”
BackgroundComprehensive review on inter‐turn fault indexes in permanent magnet motors
Faiz, J., Nejadi‐Koti, H., & Valipour, Z. (2017) · IET Electric Power Applications · doi:10.1049/iet-epa.2016.0196 · Cited by 86
Novel Diagnostic Techniques for Rotating Electrical Machines—A Review
Frosini, L. (2020) · Energies · doi:10.3390/en13195066 · Cited by 67
“Later, in [26], the following set of frequencies was highlighted in the external stray flux: ( γ Nr p (1− s) ± ν ) fs (5)”
BackgroundSpeed/position sensor fault tolerant control in adjustable speed drives – A review
Bourogaoui, M., Sethom, H. B. A., & Belkhodja, I. S. (2016) · ISA Transactions · doi:10.1016/j.isatra.2016.05.003 · Cited by 67
On the short-circuiting Fault Detection in a PMSM by means of Stator Current Transformations
Rosero, J. A., Romeral, L., Cusido, J., Garcia, A., & Ortega, J. A. (2007) · 2007 IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2007.4342300 · Cited by 63
“The harmonic order is directly related with the slot number twice the polar step, and his magnitude depends on the distribution winding factor [6], [ 7 ].”
BackgroundKrzysztofiak, M., Skowron, M., & Orlowska-Kowalska, T. (2020) · Energies · doi:10.3390/en14010153 · Cited by 33
Improved ZSVC‐based fault detection technique for incipient stage inter‐turn fault in PMSM
Fang, J., Sun, Y., Wang, Y., Wei, B., & Hang, J. (2019) · IET Electric Power Applications · doi:10.1049/iet-epa.2019.0016 · Cited by 30
A Novel Fault Diagnosis Technique for IPMSM Using Voltage Angle
Ullah, Z., Lee, S.-T., & Hur, J. (2018) · 2018 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2018.8557375 · Cited by 13
“Many techniques have been proposed to diagnose ITSF, which are based on partial discharge [4], voltage signal [5], stator current dq-axis or Park’s vector [6], [7],negative sequence in stator current [8], the components of the sequence impedance matrix [9], searching coil [10], [11], injecting high frequency signal [1…”
Background
Metadata
- Authors
- Henao, H., Demian, C., & Capolino, G.-A.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2003-09
- Volume
- 39
- Issue
- 5
- Pages
- 1272-1279
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W2173731758
- Cited by
- 361
- References
- 4
- FWCI
- 17.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.