On the short-circuiting Fault Detection in a PMSM by means of Stator Current Transformations
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
This paper examines winding faults as short circuit for permanent magnet synchronous motor (PMSM). The study is carried out by means of stator current harmonic analysis. dq0 current transformation is also used to diagnose the state of the machine, and Wavelet approach is proposed to extend the analysis to the transitory of the failure. Experimental results for the full range of speeds have been obtained, which demonstrate the claims of the paper.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Additionally, as proven in [41], the stator winding ITSC may cause an increase in the slot harmonics, which are calculated with the following equation:”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [41]
Citations
Cites
A Wavelet Tour of Signal Processing
(1999) · Elsevier eBooks · doi:10.1016/b978-0-12-466606-1.x5000-4 · Cited by 16,227
Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382
Detection and location of interturn short circuits in the stator windings of operating motors
Penman, J., Sedding, H. G., Lloyd, B. A., & Fink, W. T. (1994) · IEEE Transactions on Energy Conversion · doi:10.1109/60.368345 · Cited by 394
Henao, H., Demian, C., & Capolino, G.-A. (2003) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2003.816531 · Cited by 361
Performance of interior permanent magnet motor drive over wide speed range
Uddin, M. N., Radwan, T. S., & Rahman, M. A. (2002) · IEEE Transactions on Energy Conversion · doi:10.1109/60.986441 · Cited by 185
Performance of Interior Permanent Magnet Motor Drive over Wide Speed Range
Uddin, M. N., Radwan, T. S., & Rahman, M. A. (2002) · IEEE Power Engineering Review · doi:10.1109/mper.2002.4311984 · Cited by 117
Operation of a fault tolerant PM drive for an aerospace fuel pump application
Haylock, J. A. (1997) · Eighth International Conference on Electrical Machines and Drives · doi:10.1049/cp:19971053 · Cited by 101
Operation of a fault tolerant PM drivefor an aerospace fuel pump application
Haylock, J. A., Mecrow, B. C., Jack, A. G., & Atkinson, D. J. (1998) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:19982164 · Cited by 95
Investigation of a fault tolerant and high performance motor drive for critical applications
Ertuğrul, N., Soong, W. L., Valtenbergs, S., & Chye, H. (2002) · IEEE Region 10 Conference (TENCON) · doi:10.1109/tencon.2001.949653 · Cited by 26
Ojo, O., Osaloni, O. O., & Kshirsagar, P. (2003) · Conference record · doi:10.1109/ias.2002.1043738 · Cited by 18
Cited by
Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“Additionally, as proven in [41], the stator winding ITSC may cause an increase in the slot harmonics, which are calculated with the following equation:”
BackgroundRosero, J. A., Romeral, L., Ortega, J. A., & Rosero, E. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2011580 · Cited by 214
Self-citationZafarani, M., Bostanci, E., Qi, Y., Goktas, T., & Akin, B. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2018.2811538 · Cited by 208
Faults and Diagnosis Methods of Permanent Magnet Synchronous Motors: A Review
Chen, Y., Liang, S., Li, W., Liang, H., & Wang, C. (2019) · Applied Sciences · doi:10.3390/app9102116 · Cited by 194
Metadata
- Authors
- Rosero, J. A., Romeral, L., Cusido, J., Garcia, A., & Ortega, J. A.
- Affiliations
- Universitat Politècnica de Catalunya (ES)
- ORCID
- Ortega, J.A.
- Venue
- 2007 IEEE Power Electronics Specialists Conference
- Publisher
- IEEE
- Published
- 2007
- Pages
- 1936-1941
- ISSN
- 0275-9306 (ISSN-L)
- OpenAlex
- W2136389802
- Cited by
- 63
- References
- 11
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 2 · 2023: 4 · 2022: 5 · 2021: 3 · 2020: 5 · 2019: 6 · 2018: 5 · 2017: 4 · 2016: 7 · 2015: 2 · 2014: 4
- FWCI
- 5.72
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE Power Electronics Specialists Conference (PESC) (publishedVersion)
- TECNALIA Publications (Fundación TECNALIA Research & Innovation) (submittedVersion, public-domain)
- Topics
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Keywords
- permanent magnet synchronous motor, short circuit detection, winding faults, wavelet analysis, fault transients, condition monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: On the short-circuiting Fault Detection in a PMSM by means of Stator Current Transformations. https://app.cochat.ai/papers/10.1109/pesc.2007.4342300
- The paper
- Rosero, J. A., Romeral, L., Cusido, J., Garcia, A., & Ortega, J. A. (2007). On the short-circuiting Fault Detection in a PMSM by means of Stator Current Transformations. 2007 IEEE Power Electronics Specialists Conference. https://doi.org/10.1109/pesc.2007.4342300
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.