The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Passive Filters—Potentialities and Limitations
Abstract
New topologies for harmonic mitigation and active filters have come a long way, and these address the line-harmonic control at the source. These mitigate some of the disadvantages of passive filters, however, for nonlinear loads above 1 MW the passive filters are an economical choice. This paper discusses two types of filters: band pass filters and damped filters, which are commonly applied. The operation of these filters is described with respect to the design and system limitations. The operating constraints are then superimposed. The development of this approach shows that there are design limitations and large system changes or modifications can result in higher distortion or even damage to filters in extreme cases. The constraints and limitations that a designer faces in implementing an effective filter design with modern tools of harmonic analysis, measurements, and system analysis are discussed. The paper shows that in most distribution systems it is practical and economical to implement passive filter designs, provided the required safeguards are considered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Arrillaga, J., & Watson, N. R. (2003) · Wiley eBooks · doi:10.1002/0470871229 · Cited by 1,651
Kimbark, E. W. (1971) · Medical Entomology and Zoology · Cited by 782
Harmonic Reduction In Group-Connected Generators-HVDC Convertor
Arrillaga, J., Yonghe, L., Crimp, C. S., & Villablanca, M. (2005) · ICHPS V International Conference on Harmonics in Power Systems. · doi:10.1109/ichps.1992.559037 · Cited by 365
Harmonic Power Flow Studies Part I - Formulation and Solution
Xia, D., & Heydt, G. (1982) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1982.317171 · Cited by 278
Harmonic Power Flow Studies - Part II Implementation and Practical Application
Xia, D., & Heydt, G. T. (1982) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1982.317172 · Cited by 127
Das, J. C. (2002) · CRC Press eBooks · doi:10.1201/9780203908952 · Cited by 119
Self-citation
Cited by
A Review of Passive Power Filters for Three-Phase Grid-Connected Voltage-Source Converters
Beres, R. N., Wang, X., Liserre, M., Blaabjerg, F., & Bak, C. L. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2507203 · Cited by 535
Bajaj, M., & Singh, A. K. (2020) · International Journal of Energy Research · doi:10.1002/er.4847 · Cited by 324
Active Power Decoupling for High-Power Single-Phase PWM Rectifiers
Li, H., Zhang, K., Zhao, H., Fan, S., & Xiong, J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2208764 · Cited by 318
Digital Active Power Filter Controller Design for Current Harmonics in Power System
Ullah, A., Sheikh, I. U. H., Arshad, S., & Saleem, F. (2019) · 2019 16th International Bhurban Conference on Applied Sciences and Technology (IBCAST) · doi:10.1109/ibcast.2019.8667169 · Cited by 21
Metadata
- Authors
- Das, J. C.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2004-01
- Volume
- 40
- Issue
- 1
- Pages
- 232-241
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W2098259293
- Cited by
- 632
- References
- 6
- FWCI
- 10.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.