Incipient Bearing Fault Detection via Motor Stator Current Noise Cancellation Using Wiener Filter
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Current-based monitoring can offer significant economic savings and implementation advantages over traditional vibration monitoring for bearing fault detection. The key issue in current-based bearing fault detection is to extract bearing fault signatures from the motor stator current. Since the bearing fault signature in the stator current is typically very subtle, particularly when the fault is at an incipient stage, it is difficult to detect the fault signature directly. Therefore, in this paper, the bearing fault signature is detected alternatively by estimating and removing nonbearing fault components via a noise cancellation method. In this method, all the components of the stator current that are not related to bearing faults are regarded as noise and are estimated by a Wiener filter. Then, all these noise components are cancelled out by their estimates in a real-time fashion, and a fault indicator is established based on the remaining components which are mainly caused by bearing faults. Machine parameters, bearing dimensions, nameplate values, and the stator current spectrum distribution are not required in the method. The results of online experiments with a 20-hp induction motor under multiple load levels have confirmed the effectiveness of this method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of induction motors signature analysis as a medium for faults detection
El Hachemi Benbouzid, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873206 · Cited by 1,602
Motor bearing damage detection using stator current monitoring
Schoen, R. R., Habetler, T. G., Kamran, F., & Bartfield, R. G. (1995) · IEEE Transactions on Industry Applications · doi:10.1109/28.475697 · Cited by 761
Self-citationMotor bearing damage detection using stator current monitoring
Schoen, R. R., Habetler, T. G., Kamran, F., & Bartheld, R. G. (2002) · Proceedings of 1994 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1994.345491 · Cited by 638 · cited 2×
“Most sensorless bearing fault detection techniques such as [8]–[16] in the literature rely on locating and processing the characteristic bearing fault frequencies in the stator current and, therefore, may not be suitable for detecting generalizedroughness faults.”
Self-citationReport of Large Motor Reliability Survey of Industrial and Commercial Installations, Part I
(1985) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1985.349532 · Cited by 602
Online Diagnosis of Induction Motors Using MCSA
Jung, J.-H., Lee, J.-J., & Kwon, B.-H. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.885131 · Cited by 570
Models for Bearing Damage Detection in Induction Motors Using Stator Current Monitoring
Blodt, M., Granjon, P., Raison, B., & Rostaing, G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.917108 · Cited by 568 · cited 1×
“As a result, the characteristic fault frequencies do not necessarily exist in the stator current [7], [13], [17].”
Statistical Digital Signal Processing and Modeling
Gruber, M. H. J. (1997) · Technometrics · doi:10.1080/00401706.1997.10485128 · Cited by 489
Benbouzid, M. E. H., Vieira, M., & Theys, C. (1999) · IEEE Transactions on Power Electronics · doi:10.1109/63.737588 · Cited by 378
Stack, J. R., Habetler, T. G., & Harley, R. G. (2004) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2004.827454 · Cited by 290 · cited 3×
“As a result, the characteristic fault frequencies do not necessarily exist in the stator current [7], [13], [17].”
Self-citationBearing Damage Detection via Wavelet Packet Decomposition of the Stator Current
Eren, L., & Devaney, M. J. (2004) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2004.823323 · Cited by 282
Yazici, B., & Kliman, G. B. (1999) · IEEE Transactions on Industry Applications · doi:10.1109/28.753640 · Cited by 266 · cited 1×
“In fact, there has been many research works focusing on the detection of single-point bearing faults [9]–[16].”
Ballal, M. S., Khan, Z. J., Suryawanshi, H. M., & Sonolikar, R. L. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.888789 · Cited by 251
An Amplitude Modulation Detector for Fault Diagnosis in Rolling Element Bearings
Stack, J. R., Harley, R. G., & Habetler, T. G. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.834971 · Cited by 224
Self-citationInduction Machine Fault Detection Using SOM-Based RBF Neural Networks
Wu, S., & Chow, T. W. S. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2003.821897 · Cited by 171 · cited 2×
“In fact, there has been many research works focusing on the detection of single-point bearing faults [9]‐[ 16 ].”
BackgroundBearing Fault Detection Via Stator Current Noise Cancellation and Statistical Control
Zhou, W., Habetler, T. G., & Harley, R. G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2005018 · Cited by 165 · cited 1×
“A method based on statistical process control (SPC) has been investigated by the same authors in [21], where the fault index”
MethodSelf-citationBearing Fault Detection via Autoregressive Stator Current Modeling
Stack, J. R., Habetler, T. G., & Harley, R. G. (2004) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2004.827797 · Cited by 158
Self-citationInduction Machine Fault Diagnostic Analysis With Wavelet Technique
Chow, T. W. S., & Hai, S. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.825325 · Cited by 155
Low Order PWM Inverter Harmonics Contributions to the Inverter-Fed Induction Machine Fault Diagnosis
Akin, B., Orguner, U., Toliyat, H. A., & Rayner, M. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911954 · Cited by 140 · cited 1×
“already used for metering, controls, and electrical protection [3]–[6].”
Sensorless fault diagnosis of induction motors
Kim, K., Parlos, A. G., & Bharadwaj, R. M. (2003) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2003.817693 · Cited by 89 · cited 1×
“already used for metering, controls, and electrical protection [3]–[6].”
Cited by
Trends in Fault Diagnosis for Electrical Machines: A Review of Diagnostic Techniques
Henao, H., Capolino, G.-A., Fernandez-Cabanas, M., Filippetti, F., Bruzzese, C., Strangas, E., Pusca, R., Estima, J., Riera-Guasp, M., & Hedayati-Kia, S. (2014) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2013.2287651 · Cited by 602
Vibration analysis for bearing fault detection and classification using an intelligent filter
Zarei, J., Tajeddini, M. A., & Karimi, H. R. (2014) · Mechatronics · doi:10.1016/j.mechatronics.2014.01.003 · Cited by 269
Bearing Fault Diagnosis for Direct-Drive Wind Turbines via Current-Demodulated Signals
Gong, X., & Qiao, W. (2013) · Industrial Electronics, IEEE Transactions on · doi:10.1109/tie.2013.2238871 · Cited by 195
“attention due to their advantages over other methods in terms of cost, implementation, and system reliability [5].”
BackgroundKang, M., Kim, J., Kim, J.-M., Tan, A. C. C., Kim, E. Y., & Choi, B.-K. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2358494 · Cited by 169
Sun, M., Wang, H., Liu, P., Huang, S., & Fan, P. (2019) · Measurement · doi:10.1016/j.measurement.2019.06.029 · Cited by 168
Metadata
- Authors
- Zhou, W., Lu, B., Habetler, T. G., & Harley, R. G.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2009-07
- Volume
- 45
- Issue
- 4
- Pages
- 1309-1317
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2096764068
- Cited by
- 165
- References
- 19
- FWCI
- 8.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.