The measurement of the junction temperature with thermosensitive electrical parameters (TSEPs) is largely used by electrical engineers or researchers, but the obtained temperature value is generally not verified by any referential information of the actual chip temperature distribution. In this paper, we propose to use infrared (IR) measurements in order to evaluate the relevance of three commonly used TSEPs with insulated gate bipolar transistor chips: the saturation voltage under a low current, the gate-emitter voltage, and the saturation current. TheIR measurements are presented in detail with an estimation of the emissivity of the black paint deposited on the power module. The temperatures obtained with IR measurements and with the different TSEPs are then compared in two cases: the use of only one chip and the use of two paralleled chips.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Temperature measurements of semiconductor devices - a review
Blackburn, D. L. (2004) · Twentieth Annual IEEE Semiconductor Thermal Measurement and Management Symposium (IEEE Cat. No.04CH37545) · doi:10.1109/stherm.2004.1291304 · Cited by 319
Real-Time Compact Thermal Models for Health Management of Power Electronics
Musallam, M., & Johnson, C. M. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2040634 · Cited by 196
Transient Electrothermal Simulation of Power Semiconductor Devices
Du, B., Hudgins, J. L., Santi, E., Bryant, A. T., Palmer, P., & Mantooth, H. A. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2029105 · Cited by 162
Transient temperature measurements and modeling of IGBT's under short circuit
Ammous, A., Allard, B., & Morel, H. (1998) · IEEE Transactions on Power Electronics · doi:10.1109/63.654955 · Cited by 116
Schmidt, R., & Scheuermann, U. (2009) · European Conference on Power Electronics and Applications · Cited by 115
Estimation and Measurement of Junction Temperatures in a Three-Level Voltage Source Converter
Brckner, T., & Bernet, S. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.886651 · Cited by 111
Perpiñà, X., Servière, J. F., Saiz, J., Barlini, D., Mermet-Guyennet, M., & Millán, J. (2006) · Microelectronics Reliability · doi:10.1016/j.microrel.2006.07.078 · Cited by 104
Power cycling results for different control strategies
Scheuermann, U., & Schuler, S. C. (2010) · Microelectronics Reliability · doi:10.1016/j.microrel.2010.07.135 · Cited by 100
The Electrothermal Large-Signal Model of Power MOS Transistors for SPICE
Zarebski, J., & Górecki, K. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2036850 · Cited by 74
Carubelli, S., & Khatir, Z. (2003) · Microelectronics Journal · doi:10.1016/s0026-2692(03)00205-2 · Cited by 64
Important properties of transient thermal impedance for MOS-gated power semiconductors
Jakopovic, Z., Benčić, Z., & Kolonić, F. (2003) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.1999.798675 · Cited by 40
Thermal characterization of IGBT power modules
Cova, P., Ciappa, M., Franceschini, G., Malberti, P., & Fantini, F. (1997) · Microelectronics Reliability · doi:10.1016/s0026-2714(97)00150-9 · Cited by 26
Rodriguez, M. P., Shammas, N. Y. A., Plumpton, A., Newcombe, D. R., & Crees, D. E. (2000) · Microelectronics Reliability · doi:10.1016/s0026-2714(99)00250-4 · Cited by 26
Cited by
Avenas, Y., Dupont, L., & Khatir, Z. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2178433 · Cited by 559
Self-citationThermal Management on IGBT Power Electronic Devices and Modules
Qian, C., Gheitaghy, A. M., Fan, J., Tang, H., Sun, B., Ye, H., & Zhang, G. (2018) · IEEE Access · doi:10.1109/access.2018.2793300 · Cited by 342
Review of Power Semiconductor Device Reliability for Power Converters
School of Electrical Engineering, C. U., & Wang, B. (2017) · CPSS Transactions on Power Electronics and Applications · doi:10.24295/cpsstpea.2017.00011 · Cited by 174
IGBT Junction Temperature Measurement via Peak Gate Current
Baker, N., Munk-Nielsen, S., Iannuzzo, F., & Liserre, M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464714 · Cited by 166
“thermally stressed in the case of two paralleled chips [11]–[13].”
Backgroundvan Erp, R., Kampitsis, G., & Matioli, E. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2959736 · Cited by 97
“Alternatively, IR measurements can provide junction temperature information during normal operation of the device, given that that the setup permits visual monitoring and a good correlation between the junction and case temperature is available [44].”
Background
Metadata
- Authors
- Dupont, L., Avenas, Y., & Jeannin, P.-O.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2013-07
- Volume
- 49
- Issue
- 4
- Pages
- 1599-1608
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2042575274
- Cited by
- 231
- References
- 13
- FWCI
- 5.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.