Diagnosis and Tolerant Strategy of an Open-Switch Fault for T-Type Three-Level Inverter Systems
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
This paper proposes a new diagnosis method of an open-switch fault and fault-tolerant control strategy for T-type three-level inverter systems. The location of the faulty switch can be identified by the average of the normalized phase current and the change of the neutral-point voltage. The proposed fault-tolerant strategy is explained by dividing into two cases: the faulty condition of half-bridge switches and neutral-point switches. The performance of the T-type inverter system improves considerably by the proposed fault-tolerant algorithm when a switch fails. The proposed method does not require additional components and complex calculations. Simulation and experimental results verify the feasibility of the proposed fault diagnosis and fault-tolerant control strategy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schweizer, M., & Kolar, J. W. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2203151 · Cited by 1,006
A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters
Lu, B., & Sharma, S. K. (2009) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2009.2027535 · Cited by 985
Survey on Fault Operation on Multilevel Inverters
Lezana, P., Pou, J., Meynard, T. A., Rodriguez, J., Ceballos, S., & Richardeau, F. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2032194 · Cited by 384
Fault-Tolerant Design and Control Strategy for Cascaded H-Bridge Multilevel Converter-Based STATCOM
Song, W., & Huang, A. Q. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2036019 · Cited by 358
Fault Diagnostic System for a Multilevel Inverter Using a Neural Network
Khomfoi, S., & Tolbert, L. M. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.897128 · Cited by 291
Maharjan, L., Yamagishi, T., Akagi, H., & Asakura, J. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2047407 · Cited by 242
Method for Detecting an Open-Switch Fault in a Grid-Connected NPC Inverter System
Choi, U.-M., Jeong, H.-G., Lee, K.-B., & Blaabjerg, F. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2178435 · Cited by 241
Self-citationA Unique Fault-Tolerant Design for Flying Capacitor Multilevel Inverter
Kou, X., Corzine, K. A., & Familiant, Y. L. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.830037 · Cited by 185
Comparison of the chip area usage of 2-level and 3-level voltage source converter topologies
Schweizer, M., Lizama, I., Friedli, T., & Kolar, J. W. (2010) · IECON 2010 - 36th Annual Conference on IEEE Industrial Electronics Society · doi:10.1109/iecon.2010.5674994 · Cited by 168
Choi, U., Lee, H.-H., & Lee, K. (2013) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2013.2257786 · Cited by 158
Self-citationDetection Method for Open-Circuit Fault in Neutral-Point-Clamped Inverter Systems
Kim, T., Lee, W., & Hyun, D.-S. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2019775 · Cited by 139
Performance Evaluation of Fault-Tolerant Neutral-Point-Clamped Converters
Ceballos, S., Pou, J., Robles, E., Zaragoza, J., & Martín, J. L. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2026710 · Cited by 124 · cited 2×
“In [14] and [15], the additional fourth leg replaces the faulty leg when the fault occurs.”
BackgroundFault-Tolerant Neutral-Point-Clamped Converter Solutions Based on Including a Fourth Resonant Leg
Ceballos, S., Pou, J., Zaragoza, J., Robles, E., Villate, J. L., & Martín, J. L. M. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2069075 · Cited by 116
Fault diagnosis of three-parallel voltage-source converter for a high-power wind turbine
Ko, Y., Lee, K., Lee, D., & Kim, J.-M. (2012) · IET Power Electronics · doi:10.1049/iet-pel.2011.0109 · Cited by 84
Self-citationNew IGBT modules for advanced neutral-point-clamped 3-level power converters
Komatsu, K., Yatsu, M., Miyashita, S., Okita, S., Nakazawa, H., Igarashi, S., Takahashi, Y., Okuma, Y., Seki, Y., & Fujihira, T. (2010) · doi:10.1109/ipec.2010.5543275 · Cited by 66
Ko, Y., & Lee, K. (2010) · Journal of Power Electronics · doi:10.6113/jpe.2010.10.6.686 · Cited by 54
Self-citationChoi, U., & Lee, K. (2013) · Journal of Power Electronics · doi:10.6113/jpe.2013.13.2.243 · Cited by 42
Self-citationChoi, U., & Lee, K. (2012) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2012.6342254 · Cited by 20
Self-citationDiagnosis method of an open-switch fault for a grid-connected T-type three-level inverter system
Choi, U., Lee, K. B., & Blaabjerg, F. (2012) · IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) · doi:10.1109/pedg.2012.6254044 · Cited by 20
Self-citation
Cited by
Study and Handling Methods of Power IGBT Module Failures in Power Electronic Converter Systems
Choi, U.-M., Blaabjerg, F., & Lee, K.-B. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2373390 · Cited by 700
Self-citationSurvey on Fault-Tolerant Techniques for Power Electronic Converters
Zhang, W., Xu, D., Enjeti, P. N., Li, H., Hawke, J. T., & Krishnamoorthy, H. S. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2304561 · Cited by 587
Reliability Improvement of a T-Type Three-Level Inverter With Fault-Tolerant Control Strategy
Choi, U.-M., Blaabjerg, F., & Lee, K.-B. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2325891 · Cited by 258
Self-citationOpen-Circuit Fault Diagnosis and Fault-Tolerant Control for a Grid-Connected NPC Inverter
Choi, U.-M., Lee, J.-S., Blaabjerg, F., & Lee, K.-B. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2510224 · Cited by 252
“The phase currents can be normalized as given by (1) and (2) [24]”
BackgroundSelf-citationCatastrophic failure and fault-tolerant design of IGBT power electronic converters - an overview
Wu, R., Blaabjerg, F., Wang, H., Liserre, M., & Iannuzzo, F. (2013) · IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2013.6699187 · Cited by 226
“Some circuits have inherent redundant ability, such as the sparse matrix converter [66-68], and T-type three-level converter [69], which can handle open-circuit failure of switches.”
Self-citation
Metadata
- Authors
- Choi, U.-M., Lee, K.-B., & Blaabjerg, F.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2014-01
- Volume
- 50
- Issue
- 1
- Pages
- 495-508
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2090364380
- Cited by
- 257
- References
- 19
- FWCI
- 10.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.