The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Fault-Tolerant Design and Control Strategy for Cascaded H-Bridge Multilevel Converter-Based STATCOM
Abstract
Cascaded H-bridge multilevel converter (CHMC) is a promising topology for flexible ac transmission systems such as static synchronous compensator (STATCOM) applications. Attention was drawn to the issue of converter reliability due to the large number of power devices used in CHMC applications. This paper proposed an effective fault-tolerant strategy by using H-bridge building block (HBBB) redundancy in CHMC-based STATCOM. The operating principle and the control strategy of the fault tolerance are proposed and discussed. The controller design consideration for the fault-tolerant STATCOM is presented. The proposed fault-tolerant control strategy is implemented on a seven-level CHMC-based STATCOM simulation platform and a five-level CHMC-based STATCOM hardware prototype. Simulation and experimental results are illustrated to verify the feasibility of the proposed fault-tolerant design with the HBBB redundancy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multilevel inverters: a survey of topologies, controls, and applications
Rodriguez, J., Lai, J.-S., & Peng, F. Z. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.801052 · Cited by 6,715
Hingorani, N. G., & Gyugyi, L. (1999) · doi:10.1109/9780470546802 · Cited by 4,233
Multilevel Voltage-Source-Converter Topologies for Industrial Medium-Voltage Drives
Rodriguez, J., Bernet, S., Wu, B., Pontt, J. O., & Kouro, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.907044 · Cited by 2,385
Control and Performance of a Transformerless Cascade PWM STATCOM With Star Configuration
Akagi, H., Inoue, S., & Yoshii, T. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.900487 · Cited by 643
Recent developments of high power converters for industry and traction applications
Bernet, S. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.892825 · Cited by 458
Experimental fault-tolerant control of a PMSM drive
Bolognani, S., Zordan, M., & Zigliotto, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873223 · Cited by 382
Fault-Tolerant Voltage-Fed PWM Inverter AC Motor Drive Systems
de Araujo Ribeiro, R. L., Jacobina, C. B., da Silva, E. R. C., & Lima, A. M. N. (2004) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2004.825284 · Cited by 299
Operation of a Medium-Voltage Drive Under Faulty Conditions
Rodriguez, J., Hammond, P. W., Pontt, J., Musalem, R., Lezana, P., & Escobar, M. J. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.851645 · Cited by 282
Dynamic performance and control of a static VAr generator using cascade multilevel inverters
Peng, F. Z., & Lai, J.-S. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.585865 · Cited by 243
Dynamic performance and control of a static VAr generator using cascade multilevel inverters
Peng, F. Z., & Lai, J.-S. (2002) · IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting · doi:10.1109/ias.1996.560205 · Cited by 233
Cited by
A General Review of Multilevel Inverters Based on Main Submodules: Structural Point of View
Vijeh, M., Rezanejad, M., Samadaei, E., & Bertilsson, K. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2890649 · Cited by 473
Li, J., Huang, A. Q., Liang, Z., & Bhattacharya, S. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2143430 · Cited by 211
Self-citationShe, X., Huang, A. Q., Wang, F., & Burgos, R. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2216245 · Cited by 161
Self-citationAnalysis and Experimental Verification of a Fault-Tolerant HEV Powertrain
Song, Y., & Wang, B. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2245513 · Cited by 81
A modulation reconfiguration based fault-tolerant control scheme for modular multilevel converters
Shen, K., Xiao, B., Mei, J., Tolbert, L. M., Wang, J., Cai, X., & Ji, Y. (2013) · 2013 Twenty-Eighth Annual IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.2013.6520766 · Cited by 58
Metadata
- Authors
- Song, W., & Huang, A. Q.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2010-08
- Volume
- 57
- Issue
- 8
- Pages
- 2700-2708
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2096626066
- Cited by
- 358
- References
- 22
- FWCI
- 12.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fault-Tolerant Design and Control Strategy for Cascaded H-Bridge Multilevel Converter-Based STATCOM. https://app.cochat.ai/papers/10.1109/tie.2009.2036019
- The paper
- Song, W., & Huang, A. Q. (2010). Fault-Tolerant Design and Control Strategy for Cascaded H-Bridge Multilevel Converter-Based STATCOM. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2009.2036019
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.