The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Review of Communication Failure Impacts on Adaptive Microgrid Protection Schemes and the Use of Energy Storage as a Contingency
Abstract
A main challenge in the practical implementation of a microgrid is the design of an adequate protection scheme in both grid-connected and islanded modes of operation. Microgrid protection requires a fast, reliable, and robust communication system to adjust relay settings to the appropriate current level according to the operation mode. Various approaches have been implemented to deal with this problem, yet the most promising ones are the use of adaptive protection techniques abiding by the International Electrotechnical Commission (IEC) 61850 communication standard. This paper presents a review of the technical challenges for the use of classical protection techniques and the need for an enhanced, adaptive, smart protection system. However, the risk of communication link failures and cyber security threats still remain a challenge in implementing a reliable adaptive protection scheme. A contingency is essential in the event that a communication failure prevents a relay from adjusting between grid-connected and islanded mode. An adaptive protection scheme is proposed, which utilizes energy storage devices to enhance resiliency against communication outages. The proposed solution does not incur additional costs to the network, as the energy storage devices are already utilized for other purposes. A case study experimentally verifies this contingency under a worst-case scenario, where a fault occurs simultaneously with a pulsed load while operating in islanded mode with a communication failure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Exploiting the GOOSE protocol: A practical attack on cyber-infrastructure
Hoyos, J., Dehus, M., & Brown, T. X. (2012) · 2012 IEEE Globecom Workshops · doi:10.1109/glocomw.2012.6477809 · Cited by 137
Cited by
Microgrids: Overview and guidelines for practical implementations and operation
Cagnano, A., De Tuglie, E., & Mancarella, P. (2020) · Applied Energy · doi:10.1016/j.apenergy.2019.114039 · Cited by 339
Evolution of microgrids with converter-interfaced generations: Challenges and opportunities
Hossain, M. A., Pota, H. R., Hossain, M. J., & Blaabjerg, F. (2019) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2019.01.038 · Cited by 309
Ilyushin, P., Volnyi, V., Suslov, K., & Filippov, S. (2022) · Energies · doi:10.3390/en15239186 · Cited by 30
Metadata
- Authors
- Habib, H. F., Lashway, C. R., & Mohammed, O. A.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2018-03
- Volume
- 54
- Issue
- 2
- Pages
- 1194-1207
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2770421461
- Cited by
- 167
- References
- 1
- FWCI
- 12.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Review of Communication Failure Impacts on Adaptive Microgrid Protection Schemes and the Use of Energy Storage as a Contingency. https://app.cochat.ai/papers/10.1109/tia.2017.2776858
- The paper
- Habib, H. F., Lashway, C. R., & Mohammed, O. A. (2018). A Review of Communication Failure Impacts on Adaptive Microgrid Protection Schemes and the Use of Energy Storage as a Contingency. IEEE Transactions on Industry Applications. https://doi.org/10.1109/tia.2017.2776858
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.