The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
An Improved Feedforward Control Method Considering PLL Dynamics to Improve Weak Grid Stability of Grid-Connected Inverters
Abstract
Phase-locked loop (PLL) is commonly used for three-phase grid-connected inverters to obtain the information of grid synchronization, and PLL dynamics are the key factors for stable operation of the inverters. Under weak grid conditions, the coupling between PLL and grid impedance can result in harmonic resonance, or even instability in the system. In this paper, the effect of PLL dynamics and grid impedance on the stability of three-phase grid-connected inverters is studied with the d-q impedance model. Besides, the variable transfer relationship is used to analyze the influence of PLL perturbations on output current under weak grid conditions. To suppress low-order harmonics of the network current caused by PLL perturbations under weak grid conditions, a novel feedforward control method is proposed to compensate PLL perturbations and revise the output impedance, where the operation of the inverter and PLL dynamics have been taken into account in the design process. By analyzing the impedance characteristic of the system, it can be demonstrated that the proposed method can enhance the stability of grid-connected inverters under weak grid conditions and reduce the impact of PLL perturbations on grid-connecting current. The experimental results indicate that the low-order harmonics of the network current can be suppressed effectively, which verifies the analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220
Analysis of D-Q Small-Signal Impedance of Grid-Tied Inverters
Wen, B., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2398192 · Cited by 1,334
Impedance Modeling and Analysis of Grid-Connected Voltage-Source Converters
Cespedes, M., & Sun, J. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2262473 · Cited by 1,167
Input-Admittance Calculation and Shaping for Controlled Voltage-Source Converters
Harnefors, L., Bongiorno, M., & Lundberg, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.904022 · Cited by 1,117
Modeling and Analysis of Harmonic Stability in an AC Power-Electronics-Based Power System
Wang, X., Blaabjerg, F., & Wu, W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2306432 · Cited by 785
Zhou, J. Z., Ding, H., Fan, S., Zhang, Y., & Gole, A. M. (2014) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2014.2330518 · Cited by 738
Small-Signal Methods for AC Distributed Power Systems–A Review
Sun, J. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2029859 · Cited by 712
Dong, D., Wen, B., Boroyevich, D., Mattavelli, P., & Xue, Y. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2334665 · Cited by 709
Virtual-Impedance-Based Control for Voltage-Source and Current-Source Converters
Wang, X., Li, Y. W., Blaabjerg, F., & Loh, P. C. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2382565 · Cited by 670
Impedance-Based Analysis of Grid-Synchronization Stability for Three-Phase Paralleled Converters
Wen, B., Dong, D., Boroyevich, D., Burgos, R., Mattavelli, P., & Shen, Z. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2419712 · Cited by 586
Cited by
Grid-Synchronization Stability of Converter-Based Resources—An Overview
Wang, X., Taul, M. G., Wu, H., Liao, Y., Blaabjerg, F., & Harnefors, L. (2020) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2020.3020392 · Cited by 862
Ravanji, M. H., Rathnayake, D. B., Mansour, M. Z., & Bahrani, B. (2023) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2023.3246566 · Cited by 47
Metadata
- Authors
- Zhang, X., Xia, D., Fu, Z., Wang, G., & Xu, D.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2018-09
- Volume
- 54
- Issue
- 5
- Pages
- 5143-5151
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2793816164
- Cited by
- 262
- References
- 15
- FWCI
- 14.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Improved Feedforward Control Method Considering PLL Dynamics to Improve Weak Grid Stability of Grid-Connected Inverters. https://app.cochat.ai/papers/10.1109/tia.2018.2811718
- The paper
- Zhang, X., Xia, D., Fu, Z., Wang, G., & Xu, D. (2018). An Improved Feedforward Control Method Considering PLL Dynamics to Improve Weak Grid Stability of Grid-Connected Inverters. IEEE Transactions on Industry Applications. https://doi.org/10.1109/tia.2018.2811718
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.