The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
DC-Bus Signaling: A Distributed Control Strategy for a Hybrid Renewable Nanogrid
Abstract
A dc nanogrid is a hybrid renewable system since renewable sources supply the average load demand, while storage and nonrenewable generation maintain the power balance in the presence of the stochastic renewable sources. The system is power electronic based, with converters being used to interface both the sources and loads to the system. The nanogrid is controlled using dc-bus signaling (DBS), a distributed control strategy in which the control nodes, the source/storage interface converters, induce voltage-level changes to communicate with the other control nodes. This paper explains the control structure required for the converters to permit the use of DBS, and explains a procedure for implementing a system-wide control law through independent control of the source/storage interface converters. Experimental results are presented to demonstrate the operation of this novel control strategy
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lasseter, R. H. (2003) · 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309) · doi:10.1109/pesw.2002.985003 · Cited by 1,997
Impedance specifications for stable DC distributed power systems
Feng, X., Liu, J., & Lee, F. C. (2002) · IEEE Transactions on Power Electronics · doi:10.1109/63.988825 · Cited by 582
Decentralized generator scheduling in a nanogrid using DC bus signaling
Bryan, J., Duke, R., & Round, S. D. (2004) · IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2004.1372983 · Cited by 140
Self-citation
Cited by
Guerrero, J. M., Vasquez, J. C., Matas, J., de Vicuna, L. G., & Castilla, M. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066534 · Cited by 5,075
DC Microgrids–Part I: A Review of Control Strategies and Stabilization Techniques
Dragicevic, T., Lu, X., Vasquez, J., & Guerrero, J. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2478859 · Cited by 1,564
DC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues
Dragicevic, T., Lu, X., Vasquez, J. C., & Guerrero, J. M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464277 · Cited by 1,451
Anand, S., Fernandes, B. G., & Guerrero, J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2215055 · Cited by 920
Supervisory Control of an Adaptive-Droop Regulated DC Microgrid With Battery Management Capability
Dragicevic, T., Guerrero, J. M., Vasquez, J. C., & Skrlec, D. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2257857 · Cited by 770
Metadata
- Authors
- Schonbergerschonberger, J., Duke, R., & Round, S. D.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2006-10
- Volume
- 53
- Issue
- 5
- Pages
- 1453-1460
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2105303942
- Cited by
- 573
- References
- 3
- FWCI
- 10.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.