The DOI matches its Crossref record.
Modeling Strategy for Back-to-Back Three-Level Converters Applied to High-Power Wind Turbines
Abstract
Three-level converters are becoming a realistic alternative to the conventional converters in high-power wind-energy applications. In this paper, a complete analytical strategy to model a back-to-back three-level converter is described. This tool permits us to adapt the control strategy to the specific application. Moreover, the model of different loads can be incorporated to the overall model. Both control strategy and load models are included in the complete system model. The proposed model pays special attention to the unbalance in the capacitors' voltage of three-level converters, including the dynamics of the capacitors' voltage. In order to validate the model and the control strategy proposed in this paper, a 3-MW three-level back-to-back power converter used as a power conditioning system of a variable speed wind turbine has been simulated. Finally, the described strategy has been implemented in a 50-kVA scalable prototype as well, providing a satisfactory performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey
Carrasco, J. M., Franquelo, L. G., Bialasiewicz, J. T., Galvan, E., PortilloGuisado, R. C., Prats, M. A. M., Leon, J. I., & Moreno-Alfonso, N. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.878356 · Cited by 4,018
Self-citationRecent Advances and Industrial Applications of Multilevel Converters
Kouro, S., Malinowski, M., Gopakumar, K., Pou, J., Franquelo, L. G., Wu, B., Rodriguez, J., Pérez, M. A., & Leon, J. I. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049719 · Cited by 3,872
Self-citationMultilevel Voltage-Source-Converter Topologies for Industrial Medium-Voltage Drives
Rodriguez, J., Bernet, S., Wu, B., Pontt, J. O., & Kouro, S. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.907044 · Cited by 2,385
The age of multilevel converters arrives
Franquelo, L., Rodriguez, J., Leon, J., Kouro, S., Portillo, R., & Prats, M. (2008) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2008.923519 · Cited by 2,016
Self-citationAbu-Rub, H., Holtz, J., Rodriguez, J., & Baoming, G. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2043039 · Cited by 1,337
Multilevel Converters: An Enabling Technology for High-Power Applications
Rodriguez, J., Franquelo, L. G., Kouro, S., Leon, J. I., Portillo, R. C., Prats, M. A. M., & Perez, M. A. (2009) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2030235 · Cited by 1,196
Self-citationHigh-power wind energy conversion systems: State-of-the-art and emerging technologies
Yaramasu, V., Wu, B., Sen, P. C., Kouro, S., & Narimani, M. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2378692 · Cited by 991
Overview of Multi-MW Wind Turbines and Wind Parks
Liserre, M., Cardenas, R., Molinas, M., & Rodriguez, J. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2103910 · Cited by 876
Short-Circuit and Ground Fault Analyses and Location in VSC-Based DC Network Cables
Yang, J., Fletcher, J. E., & O'Reilly, J. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2162712 · Cited by 790
Leon, J. I., Vazquez, S., & Franquelo, L. G. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2726583 · Cited by 481
Self-citationPou, J., Zaragoza, J., Ceballos, S., Saeedifard, M., & Boroyevich, D. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2050783 · Cited by 430
The New Frontier of Smart Grids
Yu, X., Cecati, C., Dillon, T., & Simões, M. G. (2011) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2011.942176 · Cited by 390
Control Strategies Based on Symmetrical Components for Grid-Connected Converters Under Voltage Dips
Alepuz, S., Busquets-Monge, S., Bordonau, J., Martinez-Velasco, J. A., Silva, C. A., Pontt, J., & Rodriguez, J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2017102 · Cited by 373
Virtual Synchronous Machines: A unified interface for grid integration
Zhong, Q.-C. (2016) · IEEE Power Electronics Magazine · doi:10.1109/mpel.2016.2614906 · Cited by 300
Pou, J., Zaragoza, J., Rodriguez, P., Ceballos, S., Sala, V. M., Burgos, R. P., & Boroyevich, D. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.894788 · Cited by 274
Metadata
- Authors
- Portillo, R. C., Prats, M. M., Leon, J. I., Sanchez, J. A., Carrasco, J. M., Galvan, E., & Franquelo, L. G.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2006-10
- Volume
- 53
- Issue
- 5
- Pages
- 1483-1491
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2170919392
- Cited by
- 233
- References
- 0
- FWCI
- 15.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.